main
John Lauer
Prepare measured cooling review and publish Board32 results clip
dd5c423
{
"candidate": "Henkel BERGQUIST SIL PAD TSP 3500, 0.254 mm",
"source": "https://datasheets.tdx.henkel.com/BERGQUIST-SIL-PAD-TSP-3500-en_GL.pdf",
"sourcePage": 1,
"method": "Simple all-heat-through-sink screening; no board heat credit. Manufacturer TO-220 reference performance, not a guaranteed application specification. Force assumes nominal 129.9618 square mm contact.",
"caseCeilingC": 55,
"ambientC": 40,
"heatW": 5.5,
"maximumCombinedCaseToAmbientKPerW": 2.727272727272727,
"maximumInterfaceKPerWWithAssumedSink": 1.227272727272727,
"rows": [
{
"pressurePsi": 10,
"referenceTO220KPerW": 2.61,
"estimatedClampForceN": 8.960550683614073,
"caseCWithAssumed1p5KPerWSink": 62.605
},
{
"pressurePsi": 25,
"referenceTO220KPerW": 2.32,
"estimatedClampForceN": 22.401376709035187,
"caseCWithAssumed1p5KPerWSink": 61.01
},
{
"pressurePsi": 50,
"referenceTO220KPerW": 2.02,
"estimatedClampForceN": 44.802753418070374,
"caseCWithAssumed1p5KPerWSink": 59.36
},
{
"pressurePsi": 100,
"referenceTO220KPerW": 1.65,
"estimatedClampForceN": 89.60550683614075,
"caseCWithAssumed1p5KPerWSink": 57.325
},
{
"pressurePsi": 200,
"referenceTO220KPerW": 1.37,
"estimatedClampForceN": 179.2110136722815,
"caseCWithAssumed1p5KPerWSink": 55.785
}
],
"decision": "Not adopted: all listed reference TO-220 points exceed the case budget with assumed sink. No change to design or acceptance limits. Installed airflow, contact, pressure and exact die-cut remain unverified."
}