← Commit history
checkpoints/board32-interface-alternatives/tsp3500-review.jsonadded+44
@@ -0,0 +1,44 @@+{+  "candidate": "Henkel BERGQUIST SIL PAD TSP 3500, 0.254 mm",+  "source": "https://datasheets.tdx.henkel.com/BERGQUIST-SIL-PAD-TSP-3500-en_GL.pdf",+  "sourcePage": 1,+  "method": "Simple all-heat-through-sink screening; no board heat credit. Manufacturer TO-220 reference performance, not a guaranteed application specification. Force assumes nominal 129.9618 square mm contact.",+  "caseCeilingC": 55,+  "ambientC": 40,+  "heatW": 5.5,+  "maximumCombinedCaseToAmbientKPerW": 2.727272727272727,+  "maximumInterfaceKPerWWithAssumedSink": 1.227272727272727,+  "rows": [+    {+      "pressurePsi": 10,+      "referenceTO220KPerW": 2.61,+      "estimatedClampForceN": 8.960550683614073,+      "caseCWithAssumed1p5KPerWSink": 62.605+    },+    {+      "pressurePsi": 25,+      "referenceTO220KPerW": 2.32,+      "estimatedClampForceN": 22.401376709035187,+      "caseCWithAssumed1p5KPerWSink": 61.01+    },+    {+      "pressurePsi": 50,+      "referenceTO220KPerW": 2.02,+      "estimatedClampForceN": 44.802753418070374,+      "caseCWithAssumed1p5KPerWSink": 59.36+    },+    {+      "pressurePsi": 100,+      "referenceTO220KPerW": 1.65,+      "estimatedClampForceN": 89.60550683614075,+      "caseCWithAssumed1p5KPerWSink": 57.325+    },+    {+      "pressurePsi": 200,+      "referenceTO220KPerW": 1.37,+      "estimatedClampForceN": 179.2110136722815,+      "caseCWithAssumed1p5KPerWSink": 55.785+    }+  ],+  "decision": "Not adopted: all listed reference TO-220 points exceed the case budget with assumed sink. No change to design or acceptance limits. Installed airflow, contact, pressure and exact die-cut remain unverified."+}
docs/build-clips.md+8
@@ -244,3 +244,11 @@ Native KiCad overview of the isolated U3/U7 manufacturer-land candidate. Source   MMBT3904 hero repair review: [6.04-second 2× clip](../videos/mmbt-hero-review/hero-review-2x.mp4). Live headless Wiki viewer capture after publication, not original creation footage. Top, oblique and underside views; final-film selection and human review pending. Native Board32 model tour is retained for engineering review, but its trial overview excerpt was rejected for cropped edges.++## Board32 current and cooling results++A 15.9-second isolated-browser recording reviews the published Board32 result plots. This is an informational insert recorded after analysis, not footage of the solver running, native CAD editing or hardware tests. Current passes under the stated copper assumptions; thermal remains unresolved. Normal speed is retained so the annotations can be read. Technical frame review and full decode passed; human editorial approval is pending.++<video width="100%" playsinline controls preload="metadata" poster="videos/board32-results-review/poster.jpg" src="videos/board32-results-review/analysis-review.mp4"></video>++[Capture provenance](../videos/board32-results-review/capture.json).
docs/completion-plan.md+4−2
@@ -11,7 +11,7 @@ Continue the custom electronic load through AIFlow, firmware/control-panel and m - [Finished-copper dependency](finished-copper-review.md): private 3rdPartyFab guide lists 0.5 oz without resolving starting versus finished copper. The user clarification is pending. Minimum finished surface and barrel copper require confirmation. At 17.5 µm, five nets fail the unchanged density limit. Do not adopt a stackup by assuming an answer. - Candidate 35 µm / 1.51 mm dielectric refinement passes six current screens at 0.1 mm, with maximum 58.14 A/mm². `checkpoints/stackup-v85/stackup-refinement-review.json` binds inputs. It does not replace the formal specification; board-only thermal still fails. -Current task-owned editor holds adopted Board32 at `C:/Users/john/adom-projects/adom-custom-electronic-load/review/ic-land-candidate/ic-land-candidate.kicad_pcb`. PCB HWND2565810,3D HWND5376044,PID32928. Formal live binding is synchronized to Board32. No recording is active. Rediscover before mutation.+Current task-owned editor holds adopted Board32 at `C:/Users/john/adom-projects/adom-custom-electronic-load/review/ic-land-candidate/ic-land-candidate.kicad_pcb`. PCB HWND2565810,PID32928; 3D viewer is closed at the latest state check. Formal live binding is synchronized to Board32. No recording is active. Rediscover before mutation.  Scaffold fit: adopted board30 uses64×72mm corner spans on the verified8mm medium-pin grid. The earlier board29 60×68mm layout had no valid placement and remains rejected. The revised nominal XY study finds224 placements. Cooling assets now share the PCB-top2.8mm GLB frame in mechanical/sensor-gh-study/assembly-sensor-gh-study.glb. This corrects the prior3.18mm datum discrepancy; actual registration, carrier strength, retention and physical Z seating remain unqualified. Board32 combined GLB canonical overview/side and pad-detail views were inspected in isolated headless Chromium; fan off/on/unknown scene tests pass. Control-panel twin and existing dashboard now use Board32. Physical registration and full fixture seating remain unverified. @@ -24,7 +24,7 @@ Scaffold fit: adopted board30 uses64×72mm corner spans on the verified8mm mediu 3. After supported physical/spec changes, rerun exact-input current and thermal acceptance. Continue fields, net tour, silkscreen, native 3D, finish and export in enforced order. Review-only manufacturing exports already exist; do not present them as released. 4. Complete firmware/calibration and molecule integration. Control panel 0.0.4 drives the digital rotor only from fresh valid hardware RPM; stale/disconnected means unknown/paused. Host tests pass; output remains locked and hardware unflashed. [Fan shutdown review](fan-shutdown-review.md) adds 240 synthetic scheduler/clock-wrap integration cases, all passing. Physical timing, sensor calibration and load accuracy remain unverified. 5. Complete procurement and component provenance. [Cost review](cost/README.md) lists $77.39 in indicative listings, with bulk-tier, internal inventory and unavailable-part exclusions and substantial assembly/process exclusions. Candidate hardware is not an approved BOM.-6. Continue significant-action captures. Inventory is 129 raw native takes, 55 reviewed excerpts (including one explicitly labelled headless review) and 40 storyboard candidates, plus two separately labeled solver-event recordings (one reviewed, one superseded). 38 scenes have synthesized draft narration in `videos/narrated-review`; the latest library-candidate scene has text only; storyboard is `videos/build-storyboard.json`, port 8798. Obtain per-clip feedback before final assembly as required by aiflow-process-video. No final film exists.+6. Continue significant-action captures. Inventory is 129 raw native takes, 56 reviewed excerpts (including two explicitly labelled headless reviews) and 40 storyboard candidates, plus two separately labeled solver-event recordings (one reviewed, one superseded). 38 scenes have synthesized draft narration in `videos/narrated-review`; the latest library-candidate scene has text only; storyboard is `videos/build-storyboard.json`, port 8798. Obtain per-clip feedback before final assembly as required by aiflow-process-video. No final film exists.  ## Tool and delivery boundaries @@ -153,3 +153,5 @@ Board32 gate continuation: Q1/J11 stale schematic footprint properties corrected Hierarchy freshness fix source2784e003197c7d94bceaed2ae55112938ce054e0 directly published to AIFlow after158workspace tests,productioncheck/build and integrations. Ownerissue adom/adom-aiflow#43. Fresh native export hashes11schematic files and matches273/273connectedpins. Tested binary remains the explicit aiflow-interface-baseline-target/debug path; installed/registry not updated. Board32 current figure artifactd7eeb80ef70497e9ce0320e4fe17b69344bb06315fe7c3d1656e3be3e64a0a2c; operating heat derivation corrected to selectedSBR diode and0.5%shunt tolerance without changing spec/limits.  Board32 has advanced through Models, Test Plan, Placement, Routing, Thermal Vias, Pours, Outline and Current. Current stepThermal fails unchanged limits. Read-only placement command/source d985e4ac858ea5a6ca257ee423e1b4288e9787fe verified104poses across stable native revision with zero placement findings. Via-plan review retains7D1/3shunt vias and the separately documented Q1 case-sink exception; optional fourth shunt via was not added. No PCB geometry changed. Full thermal and physical qualification remain unresolved.129native rawtakes/55reviewed excerpts; all eight new static verification takes rejected for the action film. No recording active. Exact-menu net framing still not visually verified, follow-up adom/kicad-bridge#121; shared bridge preserved.++Board32 continuation: TSP3500 TO-220 pressure data do not fit the retained case-temperature budget with the assumed sink; no substitution made. `docs/thermal-bench-capture.md` and the fail-closed capture checker prepare real thermal/fan-fault measurements. Twelve synthetic unit tests pass, but the unmeasured acquisition template correctly remains blocked. A reviewed15.9second headless results insert brings the excerpt inventory to56;129native raw takes remain unchanged.
docs/thermal-bench-capture.mdadded+27
@@ -0,0 +1,27 @@+# Measured cooling and fan-fault capture++No assembled-unit measurement is present. The STM32 bring-up image remains output locked. This procedure prepares evidence collection for a later reviewed bench build; it does not authorize flashing, enabling an unqualified assembly, or manufacturing release.++Use an independent case-temperature reference at the defined Q1 case location, an ambient reference, and a current measurement with sufficient bandwidth to observe shutdown. Record enable, tachometer and fault-injection timing on a common timebase. Keep the sensor location, attachment, instrument identities, calibration dates, uncertainty calculations and acquisition settings with the trace. Case temperature inferred only from the existing NTC is insufficient to qualify that NTC's attachment and lag.++Identify the exact PCB, firmware binary, MOSFET, isolator, grease application, clamp, sink, fan, duct and sensor mounting. Photograph the assembly and record its serial identifier. Establish the approved operating condition and stopping criteria before applying load. The unchanged design limits are 40 °C assumed ambient and 55 °C actual case ceiling; instrument under-reading and lag consume the available margin. The 5.5 W Q1 heat allowance is a guard condition, not a new 5.5 W customer setting.++Collect separate traces for fan loss, obstructed airflow with continuing tach pulses, tach open/short/noise, sensor open/short, communications loss, and power/reset transitions. Use the reviewed acquisition plan to define each fault's deadline, observation duration, current-off criterion and sample-gap limit. Do not infer a hardware deadline from the host scheduler test: it excludes actual MCU scheduling, I2C latency and analog current decay. Retain the temperature transient after shutdown until the acquisition plan's observation condition is met.++`tools/check_thermal_capture.py` reviews the recorded samples. Its CSV columns are:++```text+time_s,case_c,ambient_c,current_a,load_enabled,fan_rpm+```++Copy `qualification/thermal-capture.template.json` for each trace. Fill the missing entries from the actual setup and reviewed plan; file paths resolve relative to the manifest. Run:++```sh+python3 tools/check_thermal_capture.py qualification/your-capture.json --out qualification/your-review.json+```++The checker rejects missing evidence, non-finite samples, backwards time, excessive sample gaps, absent pre-fault load, excessive case temperature including stated uncertainty, residual current, late shutdown and later restart. It uses both enable deassertion and measured current decay. The timing bound includes uncertainty on both timestamps. It hashes the inputs and evidence files. Synthetic traces cannot become eligible hardware evidence.++A `sample-check-pass` covers only the supplied sampled trace and asserted uncertainty. It cannot independently verify calibration documents, test severity, instrument bandwidth, sensor placement, between-sample peaks or a complete qualification matrix. Ambient and RPM are retained observations, not proof of the specified ambient or installed airflow. A reviewer must establish those conditions and adequate measurement coverage separately. The checker does not update AIFlow gates, change firmware qualification, or approve the assembly.++The checked-in readiness report intentionally says **blocked** because no hardware capture or acquisition uncertainty is available. Twelve unit tests exercise the checker using temporary synthetic data; those tests are software evidence only.
docs/thermal-interface-alternatives.md+8
@@ -7,3 +7,11 @@ Wakefield 175-6-220P has a published drawing (18.034 × 12.7 mm, 3.5814 mm hole, Boyd 4169G provides a fully dimensioned 19.30 × 13.97 × 1.57 mm alumina option with a 3.68 mm hole. Its greater thickness changes sink height, fastener engagement and the thermal calculation. It is not interchangeable with the present 0.635 mm AlN assumption. [Manufacturer catalog, printed page 100](https://info.boydcorp.com/hubfs/Thermal/Air-Cooling/Boyd-Board-Level-Heatsinks-Catalog.pdf).  Next selection must bind an exact orderable insulator drawing, the contact area and pressure, compatible grease if required, fastener preload and tolerance stack. Recompute cooling and recheck assembled geometry together. No BOM, thermal limit or acceptance is changed by this review.++## Board32 screening update++At 5.5 W, 40 °C ambient and the unchanged 55 °C case ceiling, the total case-to-ambient budget is 2.727 K/W. With the study's assumed 1.5 K/W forced-air sink, only 1.227 K/W remains for the complete interface and spreading path. This is a calculation, not proof of installed airflow.++Henkel SIL PAD TSP 3500 at 0.254 mm has manufacturer TO-220 reference results of 2.02 K/W at 50 psi and 1.37 K/W at 200 psi. Even the latter gives 55.79 °C in the simple all-heat-through-sink calculation before additional spreading allowance. It is therefore not adopted for this budget. At the nominal contact area, 200 psi would imply about 179 N clamp force; the existing fastener study does not establish that preload. These are reference values dependent on surfaces and pressure, not guaranteed assembly specifications. [Manufacturer technical sheet](https://datasheets.tdx.henkel.com/BERGQUIST-SIL-PAD-TSP-3500-en_GL.pdf).++The reproducible pressure sweep is in `checkpoints/board32-interface-alternatives/tsp3500-review.json`. No board, operating limit, or acceptance gate changed.
qualification/thermal-capture-readiness.jsonadded+19
@@ -0,0 +1,19 @@+{+  "status": "blocked",+  "eligibleHardwareEvidence": false,+  "issues": [+    "Missing acquisition input: capture",+    "Missing acquisition input: firmware_sha256",+    "Missing acquisition input: assembly_id",+    "Missing acquisition input: acquisition_plan",+    "Missing acquisition input: calibration_evidence",+    "Missing acquisition input: case_uncertainty_c",+    "Missing acquisition input: current_uncertainty_a",+    "Missing acquisition input: time_uncertainty_s",+    "Missing acquisition input: maximum_sample_gap_s",+    "Missing acquisition input: fault_time_s",+    "Missing acquisition input: required_observation_end_s",+    "Missing acquisition input: shutdown_deadline_s",+    "Missing acquisition input: off_current_limit_a"+  ]+}
qualification/thermal-capture.template.jsonadded+19
@@ -0,0 +1,19 @@+{+  "capture": null,+  "firmware_sha256": null,+  "assembly_id": null,+  "acquisition_plan": null,+  "calibration_evidence": null,+  "case_uncertainty_c": null,+  "current_uncertainty_a": null,+  "time_uncertainty_s": null,+  "maximum_sample_gap_s": null,+  "fault_time_s": null,+  "required_observation_end_s": null,+  "shutdown_deadline_s": null,+  "off_current_limit_a": null,+  "schemaVersion": 1,+  "origin": "unmeasured",+  "board_sha256": "ea37ce6db20bae331bf41b6638fe9149a17c484e01bc2a0d7fd34917203b7fc3",+  "note": "Future acquisition template. No prototype measurement exists. Do not populate with synthetic data or use to unlock firmware."+}
tests/test_thermal_capture.pyadded+67
@@ -0,0 +1,67 @@+import copy+import importlib.util+import json+from pathlib import Path+import tempfile+import unittest++spec = importlib.util.spec_from_file_location('thermal_capture', Path(__file__).resolve().parents[1] / 'tools/check_thermal_capture.py')+checker = importlib.util.module_from_spec(spec); spec.loader.exec_module(checker)++class ThermalCaptureTests(unittest.TestCase):+    def setUp(self):+        self.tmp = tempfile.TemporaryDirectory(); self.addCleanup(self.tmp.cleanup)+        self.root = Path(self.tmp.name)+        (self.root / 'plan.md').write_text('Synthetic unit-test acquisition plan; never hardware evidence.')+        (self.root / 'calibration.md').write_text('Synthetic unit-test evidence; never actual calibration.')+        self.manifest = {'capture': 'capture.csv', 'origin': 'synthetic',+            'board_sha256': 'a'*64, 'firmware_sha256': 'b'*64, 'assembly_id': 'synthetic-test',+            'acquisition_plan': 'plan.md', 'calibration_evidence': 'calibration.md',+            'case_uncertainty_c': 0.5, 'current_uncertainty_a': 0.001,+            'time_uncertainty_s': 0.001, 'maximum_sample_gap_s': 0.011,+            'fault_time_s': 0.015, 'required_observation_end_s': 0.06,+            'shutdown_deadline_s': 0.03, 'off_current_limit_a': 0.01}+        self.rows = [[i/100, 52, 40, 1 if i < 3 else 0, 1 if i < 3 else 0, 6000 if i < 2 else 0] for i in range(8)]+    def run_review(self):+        (self.root / 'manifest.json').write_text(json.dumps(self.manifest))+        (self.root / 'capture.csv').write_text('time_s,case_c,ambient_c,current_a,load_enabled,fan_rpm\n' + '\n'.join(','.join(map(str,r)) for r in self.rows))+        return checker.review(self.root / 'manifest.json')+    def test_synthetic_is_never_qualification(self):+        r=self.run_review();self.assertEqual(r['status'],'fail');self.assertFalse(r['eligibleHardwareEvidence'])+        self.assertEqual(len(r['issues']),1);self.assertAlmostEqual(r['observedShutdownUpperLatencyS'],0.017)+    def test_missing_inputs_block(self):+        self.manifest['case_uncertainty_c']=None+        self.assertEqual(self.run_review()['status'],'blocked')+    def test_uncertain_overtemperature_fails(self):+        self.rows[3][1]=54.6+        self.assertTrue(any('55 C' in s for s in self.run_review()['issues']))+    def test_last_restart_is_not_hidden_by_first_off(self):+        self.rows[6][3]=1;self.rows[6][4]=1+        self.assertTrue(any('deadline' in s for s in self.run_review()['issues']))+    def test_enable_off_but_current_present_fails(self):+        for r in self.rows:r[3]=1+        self.assertTrue(any('No sustained' in s for s in self.run_review()['issues']))+    def test_no_loaded_start_fails(self):+        for r in self.rows:r[3]=0;r[4]=0+        self.assertTrue(any('not exercised' in s for s in self.run_review()['issues']))+    def test_gap_fails(self):+        del self.rows[4]+        self.assertTrue(any('sample gaps' in s for s in self.run_review()['issues']))+    def test_nonmonotonic_fails(self):+        self.rows[4][0]=self.rows[3][0]+        with self.assertRaises(ValueError):self.run_review()+    def test_nan_fails(self):+        self.rows[3][1]='NaN'+        with self.assertRaises(ValueError):self.run_review()+    def test_missing_calibration_fails(self):+        self.manifest['calibration_evidence']='absent.md'+        self.assertTrue(any('Missing evidence' in s for s in self.run_review()['issues']))+    def test_short_capture_fails(self):+        self.rows=self.rows[:5]+        self.assertTrue(any('cover pre-fault' in s for s in self.run_review()['issues']))+    def test_measured_branch_logic_only(self):+        # In-memory branch test, not persisted or claimed as a real measurement.+        self.manifest['origin']='measured-hardware'+        self.assertEqual(self.run_review()['status'],'sample-check-pass')++if __name__=='__main__':unittest.main()
tools/check_thermal_capture.pyadded+129
@@ -0,0 +1,129 @@+"""Review a bench thermal capture without changing AIFlow acceptance or hardware state.++CSV columns: time_s, case_c, ambient_c, current_a, load_enabled, fan_rpm.+This checks recorded samples only; sampling gaps, sensor placement and calibration+remain part of the reviewed acquisition plan. It cannot certify between-sample peaks.+"""+import argparse+import csv+import hashlib+import json+import math+from pathlib import Path+++def finite(value, name):+    if isinstance(value, bool):+        raise ValueError(f'{name}: boolean is not a measurement')+    v = float(value)+    if not math.isfinite(v):+        raise ValueError(f'{name}: non-finite value')+    return v+++def review(manifest_path):+    manifest_path = Path(manifest_path)+    m = json.loads(manifest_path.read_text())+    required = ['capture', 'origin', 'board_sha256', 'firmware_sha256',+                'assembly_id', 'acquisition_plan', 'calibration_evidence',+                'case_uncertainty_c', 'current_uncertainty_a',+                'time_uncertainty_s', 'maximum_sample_gap_s',+                'fault_time_s', 'required_observation_end_s',+                'shutdown_deadline_s', 'off_current_limit_a']+    missing = [k for k in required if m.get(k) is None or m.get(k) == '']+    if missing:+        return {'status': 'blocked', 'eligibleHardwareEvidence': False,+                'issues': ['Missing acquisition input: ' + k for k in missing]}+    issues = []+    if m['origin'] != 'measured-hardware':+        issues.append('Synthetic or unknown origin: not hardware qualification evidence')+    for name in ['board_sha256', 'firmware_sha256']:+        h = m[name]+        if not isinstance(h, str) or len(h) != 64 or any(c not in '0123456789abcdef' for c in h):+            issues.append('Invalid identity: ' + name)+    evidence_hashes = {}+    for key in ['acquisition_plan', 'calibration_evidence']:+        p = manifest_path.parent / m[key]+        if not p.is_file() or not p.stat().st_size:+            issues.append('Missing evidence file: ' + key)+        else:+            evidence_hashes[key] = hashlib.sha256(p.read_bytes()).hexdigest()+    values = {k: finite(m[k], k) for k in required if k.endswith(('_c', '_a', '_s'))}+    for k in ['case_uncertainty_c', 'current_uncertainty_a', 'time_uncertainty_s']:+        if values[k] < 0:+            raise ValueError(k + ' must be nonnegative')+    for k in ['maximum_sample_gap_s', 'shutdown_deadline_s', 'off_current_limit_a']:+        if values[k] <= 0:+            raise ValueError(k + ' must be positive')+    capture = manifest_path.parent / m['capture']+    if not capture.is_file():+        return {'status': 'blocked', 'eligibleHardwareEvidence': False,+                'issues': issues + ['Capture file does not exist']}+    rows = []+    with capture.open(newline='') as f:+        for row in csv.DictReader(f):+            r = {k: finite(row[k], k) for k in ['time_s', 'case_c', 'ambient_c', 'current_a', 'load_enabled', 'fan_rpm']}+            if r['load_enabled'] not in [0, 1] or r['fan_rpm'] < 0:+                raise ValueError('Invalid enable/RPM sample')+            rows.append(r)+    if len(rows) < 2:+        raise ValueError('At least two samples required')+    gaps = [b['time_s'] - a['time_s'] for a, b in zip(rows, rows[1:])]+    if min(gaps) <= 0:+        raise ValueError('Sample times must be strictly increasing')+    if max(gaps) > values['maximum_sample_gap_s'] + 1e-12:+        issues.append('Acquisition contains excessive sample gaps')+    fault = values['fault_time_s']+    end = values['required_observation_end_s']+    deadline = fault + values['shutdown_deadline_s']+    if end <= deadline:+        raise ValueError('Observation end must be after the shutdown deadline')+    if rows[0]['time_s'] >= fault or rows[-1]['time_s'] < end:+        issues.append('Capture does not cover pre-fault and required post-fault window')+    pre = [r for r in rows if r['time_s'] < fault]+    if not any(r['load_enabled'] == 1 and r['current_a'] > values['off_current_limit_a'] for r in pre):+        issues.append('No loaded pre-fault sample; shutdown was not exercised')+    peak = max(r['case_c'] for r in rows) + values['case_uncertainty_c']+    if peak > 55:+        issues.append('Recorded case temperature plus stated uncertainty exceeds unchanged 55 C ceiling')+    def off(r):+        return r['load_enabled'] == 0 and abs(r['current_a']) + values['current_uncertainty_a'] <= values['off_current_limit_a']+    # Accept only a sustained observed off state, including timestamp uncertainty.+    last_on = max((i for i, r in enumerate(rows) if not off(r)), default=-1)+    first = rows[last_on + 1] if last_on + 1 < len(rows) else None+    latency = None+    if first is None:+        issues.append('No sustained observed off state')+    else:+        latency = first['time_s'] - fault + 2 * values['time_uncertainty_s']+        if first['time_s'] < fault:+            issues.append('Sustained off state predates the fault')+        if latency > values['shutdown_deadline_s'] + 1e-12:+            issues.append('Observed shutdown exceeds supplied test-plan deadline including timing uncertainty')+    return {'status': 'fail' if issues else 'sample-check-pass',+            'eligibleHardwareEvidence': not issues and m['origin'] == 'measured-hardware',+            'issues': issues, 'sampleCount': len(rows),+            'maximumSampleGapS': max(gaps), 'peakCaseUpperBoundC': peak,+            'observedShutdownUpperLatencyS': latency,+            'captureSha256': hashlib.sha256(capture.read_bytes()).hexdigest(),+            'manifestSha256': hashlib.sha256(manifest_path.read_bytes()).hexdigest(),+            'evidenceHashes': evidence_hashes,+            'limits': 'Recorded-sample review only. Does not verify sensor placement, uncertainty validity, test severity, between-sample behavior, airflow, calibration contents or reviewer approval. Does not pass AIFlow or unlock firmware.'}+++def main():+    p = argparse.ArgumentParser(description=__doc__)+    p.add_argument('manifest');p.add_argument('--out')+    args = p.parse_args()+    try:+        result = review(args.manifest)+    except (ValueError, KeyError, OSError, TypeError) as e:+        result = {'status': 'invalid', 'eligibleHardwareEvidence': False, 'issues': [str(e)]}+    text = json.dumps(result, indent=2) + '\n'+    if args.out:+        Path(args.out).write_text(text)+    print(text, end='')+    return 0 if result['status'] == 'sample-check-pass' else 2++if __name__ == '__main__':+    raise SystemExit(main())
tools/record_board32_results.mjsadded+20
@@ -0,0 +1,20 @@+// Actual browser capture of published analysis artifacts; not hardware or creation footage.+import fs from 'node:fs';+const {default:puppeteer}=await import('/home/adom/project/adom-video-brand/node_modules/puppeteer-core/lib/esm/puppeteer/puppeteer-core.js');+const out='videos/board32-results-review';fs.mkdirSync(out,{recursive:true});+const browser=await puppeteer.launch({executablePath:'/home/adom/.cache/ms-playwright/chromium-1243/chrome-linux64/chrome',headless:true,args:['--no-sandbox']});let recorder;+const pause=ms=>new Promise(r=>setTimeout(r,ms));+try {+ const page=await browser.newPage();await page.setViewport({width:1920,height:1080,deviceScaleFactor:1});+ const root='https://wiki.adom.inc/adom/adom-custom-electronic-load/render/aiflow/run/timeline/';+ const urls=['board32-current-screen.png','board32-package-thermal.png'].map(p=>root+p);+ await page.goto(urls[0],{waitUntil:'networkidle2',timeout:60000});+ await page.waitForFunction(()=>document.images[0]?.naturalWidth===1920);+ if(fs.existsSync(out+'/analysis-review.webm'))throw Error('Preserve existing take');+ const start=Date.now();recorder=await page.screencast({path:out+'/analysis-review.webm',format:'webm',fps:30,ffmpegPath:'/usr/bin/ffmpeg'});+ await pause(5000);+ await page.goto(urls[1],{waitUntil:'networkidle2',timeout:60000});+ await page.waitForFunction(()=>document.images[0]?.naturalWidth===1920);+ await pause(7000);await recorder.stop();recorder=null;+ fs.writeFileSync(out+'/capture.json',JSON.stringify({method:'Actual isolated headless Chromium screencast of published Board32 result images; analysis review, not native desktop, simulation execution or hardware footage',urls,wallMilliseconds:Date.now()-start,humanApproval:'pending',review:'pending'},null,2)+'\n');+}finally{if(recorder)await recorder.stop();await browser.close();}
videos/board32-results-review/analysis-review.mp4added
⋯ 1 unchanged line ⋯
videos/board32-results-review/capture.jsonadded+13
@@ -0,0 +1,13 @@+{+  "method": "Actual isolated headless Chromium screencast of published Board32 result images; analysis review, not native desktop, simulation execution or hardware footage",+  "urls": [+    "https://wiki.adom.inc/adom/adom-custom-electronic-load/render/aiflow/run/timeline/board32-current-screen.png",+    "https://wiki.adom.inc/adom/adom-custom-electronic-load/render/aiflow/run/timeline/board32-package-thermal.png"+  ],+  "wallMilliseconds": 18068,+  "humanApproval": "pending",+  "review": "Contact sheet inspected: both published quantitative plots are legible, thermal fail annotation retained. Informational insert only; no simulation-execution or hardware claim.",+  "encodedDurationSeconds": 15.866667,+  "frames": 476,+  "acceptedTechnicalReview": true+}
videos/board32-results-review/poster.jpgadded
⋯ 1 unchanged line ⋯
videos/inventory.json+10−1
@@ -1,6 +1,6 @@ {   "rawTakeCount": 129,-  "reviewedExcerptCount": 55,+  "reviewedExcerptCount": 56,   "countingRule": "Unique native raw window filenames; includes rejected takes and excludes derivatives, headless captures and reference projects. reviewedExcerptCount includes separately labelled accepted headless excerpts.",   "takes": [     {@@ -817,6 +817,15 @@       "excerpt": "videos/mmbt-hero-review/hero-review-2x.mp4",       "acceptedTechnicalReview": true,       "humanApproval": "pending"+    },+    {+      "file": "videos/board32-results-review/analysis-review.webm",+      "topic": "Board32 published current and thermal results review",+      "review": "videos/board32-results-review/capture.json",+      "excerpt": "videos/board32-results-review/analysis-review.mp4",+      "acceptedTechnicalReview": true,+      "humanApproval": "pending",+      "editorialRole": "Informational insert; not action or creation footage"     }   ] }