main
John Lauer
Require a qualified case-temperature bound in firmware and control panel
6d89978
ADC adapter fake-HAL: channel isolation, every-operation failure, saturation and age/wrap passed.
STM32 adapter fake-HAL: pins, endian/address encoding, zero-only DAC, age and sticky faults passed.
Fan adapter fake-HAL: clock refusal, pin/IRQ setup, edge qualification, dual wrap, IRQ-mask restoration, stale edge and delayed poll passed; no hardware timing claim.
load_core: safety policy tests passed (host C build; no MCU/HAL validation)
fan_tach: qualification, RPM, stale input, noise, slow fan, timer wrap and stale-history expiry passed
fan shutdown: 240 synthetic scheduler cases passed; observation <=15ms + poll interval; no hardware timing claim
load_protocol: host safety/framing tests passed; no MCU or USB validation
ADC nominal conversion: divider, ratiometric NTC, invalid reference and saturation tests passed.
{
"status": "diagnostic-software-checks-pass-not-qualified",
"sourceSha256": "b8797cf87f0001e2889f04dcaff5682da683560056ce479dae493310064512ea",
"curveSourceSha256": "66ee0c787b4b689547ec635b045b5e9f0d5d30bc2c672e22ff31d65f11a5caa8",
"adcCodesChecked": 4096,
"validAdcCodes": 3751,
"rejectedAdcCodes": 345,
"manufacturerTableNodes": 30,
"maxNodeErrorC": 0.0,
"monotonicSamples": 10001,
"invalidCases": 8,
"diagnosticFirmwareChanged": true,
"outputLockUnchanged": true,
"limitations": [
"No between-node manufacturer error bound",
"No physical or sensor calibration",
"No installed thermal tracking or trip qualification"
]
}
Measurement cache: conversion age, WAIT expiry, fault latch and clock wrap passed.
Instrument register, readback, signed conversion and transaction-failure tests passed.
..........................................
----------------------------------------------------------------------
Ran 42 tests in 0.117s
OK