main
John Lauer Use documented hardware dependency category for qualification handoff fb15a22
{
  "kind": "external-dependency",
  "category": "hardware",
  "reason": "Thermal acceptance requires installed low-rise cooling and sensor/lag evidence that is not available from catalog values or CAD. Current candidate is not qualified and the bring-up image is permanently output locked.",
  "dependency": "A reviewed assembled-prototype qualification setup and measured thermal/fault traces, plus verified 3rdPartyFab minimum finished surface/barrel copper. Supplier data must establish the actual TIM/clamp and installed sink assumptions before those can be adopted.",
  "resumeWhen": "Prototype availability, the finished-copper specification, or supported supplier/interface data is supplied; recheck current run and continue the corresponding design or measurement task. No cooling-size choice is required.",
  "attemptedRemedies": [
    "Completed larger-cooler fan and harness routing with component/probe clearance checks.",
    "Downloaded and inspected exact manufacturer sink CAD privately; checked top-entry tool paths against fins and proposed through-base bores.",
    "Computed unchanged-limit thermal margin and documented missing low-rise/orientation/obstruction conditions.",
    "Kept physical capture template unmeasured and firmware output locked; did not fabricate calibration.",
    "Completed independent control-session reconnect repair, host tests, disconnected panel review and source publication.",
    "Reconciled current electrical BOM and 17 previously unpriced inventory groups; no orders or stock mutations.",
    "Recorded and reviewed two additional model inspection clips; narration failure handed to TTS owner."
  ],
  "evidenceFiles": [
    "mechanical/passive-assembly-study/top-access-fin-review.json",
    "mechanical/passive-assembly-study/thermal-margin.json",
    "qualification/thermal-capture-readiness.json",
    "docs/cooling-evidence-request.md",
    "docs/finished-copper-review.md",
    "checkpoints/panel-reconnect/panel-review.json",
    "docs/cost/inventory-2026-10-12/review.json"
  ],
  "availableWork": [],
  "recordedAt": "2026-10-12T04:15:12.287738+00:00",
  "engineeringComplete": false
}