main
Ray
Publish 0.1.0
e4831dc
0805L075
LUTE · Resettable Fuses · 0805
0805L075 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Trip current (minimum) | I trip | 1.5 | A | minimum current at which device trips, 25℃ still air | 2 | ||
| Hold current (maximum) | I hold | 0.75 | A | maximum current device passes without tripping, 25℃ still air | 2 | ||
| Initial minimum resistance | R min | 0.07 | Ω | initial (un-soldered) state | 2 | ||
| Resistance after trip or reflow (maximum) | R 1max | 0.385 | Ω | 25℃, measured one hour after tripping or reflow soldering of 260℃ for 20 sec | 2 | ||
| Maximum fault current | I max | 40 | A | at rated voltage (V max) | 2 | ||
| Time to trip (maximum) | 0.2 | s | at 8.00 A fault current | 2 | |||
| Maximum voltage | V max | 6 | Vdc | 0805L075/6AR; at rated current (I max) | 2 | ||
| Maximum voltage | V max | 12 | Vdc | 0805L075/12AR; at rated current (I max) | 2 | ||
| Maximum voltage | V max | 16 | Vdc | 0805L075/16AR; at rated current (I max) | 2 | ||
| Power dissipated in tripped state | P d | 0.8 | W | 0805L075/6AR; tripped state, 25℃ still air | 2 | ||
| Power dissipated in tripped state | P d | 1 | W | 0805L075/16AR; tripped state, 25℃ still air | 2 | ||
| Maximum surface temperature in tripped state | 125 | ℃ | device in tripped state | 4 | |||
| Ambient operating temperature | -40 | 85 | ℃ | ambient operating conditions | 4 | ||
| Storage temperature | 0 | 30 | ℃ | storage condition; 30%-60% RH | 6 | ||
| Resistance change after passive aging | -5 | 5 | % | +85℃, 1000 hours; printed as ±5% typical | 4 | ||
| Resistance change after humidity aging | -5 | 5 | % | +85℃, 85% R.H., 168 hours; printed as ±5% typical | 4 | ||
| Resistance change after thermal shock | -33 | 33 | % | +85℃ to -40℃, 20 times; printed as ±33% typical | 4 | ||
| Hold current at ambient temperature | I hold | 0.75 | A | ambient -40℃; 0805L075 family derating table | 5 | ||
| Hold current at ambient temperature | I hold | 0.9 | A | ambient -20℃; 0805L075 family derating table | 5 | ||
| Hold current at ambient temperature | I hold | 0.79 | A | ambient 0℃; 0805L075 family derating table | 5 | ||
| Hold current at ambient temperature | I hold | 0.63 | A | ambient 40℃; 0805L075 family derating table | 5 | ||
| Hold current at ambient temperature | I hold | 0.57 | A | ambient 50℃; 0805L075 family derating table | 5 | ||
| Hold current at ambient temperature | I hold | 0.53 | A | ambient 60℃; 0805L075 family derating table | 5 | ||
| Hold current at ambient temperature | I hold | 0.41 | A | ambient 70℃; 0805L075 family derating table | 5 | ||
| Hold current at ambient temperature | I hold | 0.34 | A | ambient 85℃; 0805L075 family derating table | 5 |
CAD (KiCad official)
- Symbol:
0805L075 - Footprint:
Fuse:Fuse_0805_2012Metric - 3D model: 0805 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256
02a164fafb86ec79, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).
# 0805L075
**LUTE** · Resettable Fuses · 0805
0805L075 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
## Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
## Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
## Electrical characteristics
Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Trip current (minimum) | I trip | 1.5 | | | A | minimum current at which device trips, 25℃ still air | 2 |
| Hold current (maximum) | I hold | | | 0.75 | A | maximum current device passes without tripping, 25℃ still air | 2 |
| Initial minimum resistance | R min | 0.07 | | | Ω | initial (un-soldered) state | 2 |
| Resistance after trip or reflow (maximum) | R 1max | | | 0.385 | Ω | 25℃, measured one hour after tripping or reflow soldering of 260℃ for 20 sec | 2 |
| Maximum fault current | I max | | | 40 | A | at rated voltage (V max) | 2 |
| Time to trip (maximum) | | | | 0.2 | s | at 8.00 A fault current | 2 |
| Maximum voltage | V max | | | 6 | Vdc | 0805L075/6AR; at rated current (I max) | 2 |
| Maximum voltage | V max | | | 12 | Vdc | 0805L075/12AR; at rated current (I max) | 2 |
| Maximum voltage | V max | | | 16 | Vdc | 0805L075/16AR; at rated current (I max) | 2 |
| Power dissipated in tripped state | P d | | 0.8 | | W | 0805L075/6AR; tripped state, 25℃ still air | 2 |
| Power dissipated in tripped state | P d | | 1 | | W | 0805L075/16AR; tripped state, 25℃ still air | 2 |
| Maximum surface temperature in tripped state | | | | 125 | ℃ | device in tripped state | 4 |
| Ambient operating temperature | | -40 | | 85 | ℃ | ambient operating conditions | 4 |
| Storage temperature | | 0 | | 30 | ℃ | storage condition; 30%-60% RH | 6 |
| Resistance change after passive aging | | -5 | | 5 | % | +85℃, 1000 hours; printed as ±5% typical | 4 |
| Resistance change after humidity aging | | -5 | | 5 | % | +85℃, 85% R.H., 168 hours; printed as ±5% typical | 4 |
| Resistance change after thermal shock | | -33 | | 33 | % | +85℃ to -40℃, 20 times; printed as ±33% typical | 4 |
| Hold current at ambient temperature | I hold | | | 0.75 | A | ambient -40℃; 0805L075 family derating table | 5 |
| Hold current at ambient temperature | I hold | | | 0.9 | A | ambient -20℃; 0805L075 family derating table | 5 |
| Hold current at ambient temperature | I hold | | | 0.79 | A | ambient 0℃; 0805L075 family derating table | 5 |
| Hold current at ambient temperature | I hold | | | 0.63 | A | ambient 40℃; 0805L075 family derating table | 5 |
| Hold current at ambient temperature | I hold | | | 0.57 | A | ambient 50℃; 0805L075 family derating table | 5 |
| Hold current at ambient temperature | I hold | | | 0.53 | A | ambient 60℃; 0805L075 family derating table | 5 |
| Hold current at ambient temperature | I hold | | | 0.41 | A | ambient 70℃; 0805L075 family derating table | 5 |
| Hold current at ambient temperature | I hold | | | 0.34 | A | ambient 85℃; 0805L075 family derating table | 5 |
## CAD (KiCad official)
- Symbol: `0805L075`
- Footprint: `Fuse:Fuse_0805_2012Metric`
- 3D model: 0805 (KiCad packages3D, STEP)
## Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- **Datasheet:** [LUTE datasheet, copy hosted by LCSC](docs/0805l075-16ar-datasheet.pdf) (9 pp, sha256 `02a164fafb86ec79`, retrieved 2026-11-20)
- **Extractor:** parts-factory `2.0.0` / `extract_pins`, primary `two-terminal convention` (convention), consensus `off` (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
- **CAD:** KiCad official libraries (CC-BY-SA 4.0).
[Datasheet PDF](docs/0805l075-16ar-datasheet.pdf)