0805L075

LUTE · Resettable Fuses · 0805

0805L075 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0805
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Trip current (minimum) I trip 1.5 A minimum current at which device trips, 25℃ still air 2
Hold current (maximum) I hold 0.75 A maximum current device passes without tripping, 25℃ still air 2
Initial minimum resistance R min 0.07 Ω initial (un-soldered) state 2
Resistance after trip or reflow (maximum) R 1max 0.385 Ω 25℃, measured one hour after tripping or reflow soldering of 260℃ for 20 sec 2
Maximum fault current I max 40 A at rated voltage (V max) 2
Time to trip (maximum) 0.2 s at 8.00 A fault current 2
Maximum voltage V max 6 Vdc 0805L075/6AR; at rated current (I max) 2
Maximum voltage V max 12 Vdc 0805L075/12AR; at rated current (I max) 2
Maximum voltage V max 16 Vdc 0805L075/16AR; at rated current (I max) 2
Power dissipated in tripped state P d 0.8 W 0805L075/6AR; tripped state, 25℃ still air 2
Power dissipated in tripped state P d 1 W 0805L075/16AR; tripped state, 25℃ still air 2
Maximum surface temperature in tripped state 125 ℃ device in tripped state 4
Ambient operating temperature -40 85 ℃ ambient operating conditions 4
Storage temperature 0 30 ℃ storage condition; 30%-60% RH 6
Resistance change after passive aging -5 5 % +85℃, 1000 hours; printed as ±5% typical 4
Resistance change after humidity aging -5 5 % +85℃, 85% R.H., 168 hours; printed as ±5% typical 4
Resistance change after thermal shock -33 33 % +85℃ to -40℃, 20 times; printed as ±33% typical 4
Hold current at ambient temperature I hold 0.75 A ambient -40℃; 0805L075 family derating table 5
Hold current at ambient temperature I hold 0.9 A ambient -20℃; 0805L075 family derating table 5
Hold current at ambient temperature I hold 0.79 A ambient 0℃; 0805L075 family derating table 5
Hold current at ambient temperature I hold 0.63 A ambient 40℃; 0805L075 family derating table 5
Hold current at ambient temperature I hold 0.57 A ambient 50℃; 0805L075 family derating table 5
Hold current at ambient temperature I hold 0.53 A ambient 60℃; 0805L075 family derating table 5
Hold current at ambient temperature I hold 0.41 A ambient 70℃; 0805L075 family derating table 5
Hold current at ambient temperature I hold 0.34 A ambient 85℃; 0805L075 family derating table 5

CAD (KiCad official)

  • Symbol: 0805L075
  • Footprint: Fuse:Fuse_0805_2012Metric
  • 3D model: 0805 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256 02a164fafb86ec79, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF