123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540541542543544545546547548549550551552553554555556557558559560561562563564565566567568569570571572573574575576577578579580581582583584585586587588589590591592593594595596597598
{
"schema_version": 1,
"type": "component",
"slug": "0805l050-30ar",
"title": "0805L050/30AR",
"brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",
"version": "0.1.1",
"license": "CC-BY-SA-4.0",
"tags": [
"component",
"circuit protection",
"0805l050",
"factory-2.0.0",
"extractor-text"
],
"component": {
"mpn": "0805L050/30AR",
"manufacturer": "LUTE",
"package": "0805",
"pin_count": 2,
"category": "Circuit Protection",
"subcategory": "Resettable Fuses",
"datasheet": "https://datasheet.lcsc.com/datasheet/pdf/c80e82a7873dca07a5ed9267db659cb9.pdf",
"parts": {
"symbol": "0805l050-30ar.kicad_sym",
"footprint": "0805l050-30ar.kicad_mod",
"model_3d": "0805l050-30ar-hero.glb",
"model_3d_step": "0805l050-30ar.step",
"lbr": "0805l050-30ar.lbr",
"model_3d_plain": "0805l050-30ar.glb"
},
"distributor_links": {
"lcsc": "C19193039"
},
"distributor_check": {
"checked_at": "2026-11-20T16:54:54Z",
"source": "Component Ocean /api/assign-pns",
"digikey": {
"pn": null,
"status": "no match"
},
"mouser": {
"pn": null,
"status": "no match"
}
},
"pins": [
{
"number": "1",
"name": "1",
"type": "passive",
"description": "Terminal 1 of an unpolarised fuse; either orientation."
},
{
"number": "2",
"name": "2",
"type": "passive",
"description": "Terminal 2 of an unpolarised fuse; either orientation."
}
],
"provenance": {
"extractor": "extract_pins",
"factory_chain": {
"factory": "2.0.0",
"extractor": "extract_pins",
"primary_model": "two-terminal convention",
"primary_mode": "convention",
"consensus_model": null,
"consensus": "agreed",
"guards": "pin_guards 0.1: passed",
"guard_notes": [
"vision extraction: provenance cannot be text-verified; needs consensus"
],
"pages_sent": 10,
"cost_usd": 0.0031,
"at": "2026-11-20T16:54:48"
},
"datasheet": {
"url": "https://datasheet.lcsc.com/datasheet/pdf/c80e82a7873dca07a5ed9267db659cb9.pdf",
"pages": 10,
"sha256": "21e79b52aaa8e9ea",
"source_tier": "lcsc",
"citation": "LUTE datasheet, copy hosted by LCSC"
},
"cad": "KiCad official (CC-BY-SA 4.0)",
"pins": {
"total": 2,
"described": 2,
"cites_pages": true,
"refuses_to_fabricate": true
}
},
"viewers": {
"symbol": "viewers/symbol.html",
"footprint": "viewers/footprint.html"
},
"family": {
"base": "0805l050-24xr",
"base_mpn": "0805L050/24XR",
"members": [
{
"slug": "0805l050-12xr",
"mpn": "0805L050/12XR"
},
{
"slug": "0805l050-15xr",
"mpn": "0805L050/15XR"
},
{
"slug": "0805l050-16xr",
"mpn": "0805L050/16XR"
},
{
"slug": "0805l050-24xr",
"mpn": "0805L050/24XR"
},
{
"slug": "0805l050-30ar",
"mpn": "0805L050/30AR"
},
{
"slug": "0805l050-33ar",
"mpn": "0805L050/33AR"
},
{
"slug": "0805l050-6xr",
"mpn": "0805L050/6XR"
}
],
"siblings": [
"0805L050/12XR",
"0805L050/15XR",
"0805L050/16XR",
"0805L050/24XR",
"0805L050/33AR",
"0805L050/6XR"
],
"old_slug": "0805l050",
"basis": "one family name (0805L050): the parts the cut-base page adom/0805l050 stood for (slug collision split, data/slug_collisions_2026-11-09.json)"
},
"models_3d": [
{
"file": "0805l050-30ar.step",
"role": "plain",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
2,
1.25,
0.45
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "bd29ccc62530d3bcfbbe078f12aac2a99ac75d01c043a2723a4bd36540aac146",
"checked": "2026-11-20",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
}
],
"package_dims": {
"package_code": "0805",
"source_page": 4,
"D": {
"nom_mm": 2.1,
"range_mm": [
2,
2.2
]
},
"E1": {
"nom_mm": 1.35,
"range_mm": [
1.2,
1.5
]
},
"A": {
"nom_mm": 0.8,
"range_mm": [
0.5,
1.1
]
},
"source": "datasheet package drawing, every number found on its page (extract_pins --task dims)",
"model_check": {
"file": "0805l050-30ar.step",
"verdict": "PASS",
"reasons": [
"height within the datasheet's package drawing"
],
"by": "factory/package_fit.py"
}
}
},
"metadata": {
"specs": {
"Manufacturer": "LUTE",
"Package": "0805",
"Category": "Circuit Protection",
"Pins": "2"
},
"characteristics": {
"version": 1,
"source": "datasheet",
"datasheet_sha256": "21e79b52aaa8e9ead8f6ff764d7bfbed9e664190b0e90d7b103a5dcf4f847522",
"rows": [
{
"name": "Hold current, 25 °C still air (0805L050 family)",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.5,
"conditions": "0805L050/6XR, /12XR, /15XR, /16XR, /24XR, /30AR; maximum current passed without tripping, 25 °C still air",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Trip current, 25 °C still air",
"symbol": "I trip",
"kind": "electrical",
"unit": "A",
"min": 1,
"typ": null,
"max": null,
"conditions": "0805L050 family; minimum current at which device trips, 25 °C still air",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Maximum voltage, 0805L050/6XR",
"symbol": "V max",
"kind": "absolute_maximum",
"unit": "Vdc",
"min": null,
"typ": null,
"max": 6,
"conditions": "0805L050/6XR; rated voltage (at rated current I max)",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Maximum voltage, 0805L050/12XR",
"symbol": "V max",
"kind": "absolute_maximum",
"unit": "Vdc",
"min": null,
"typ": null,
"max": 12,
"conditions": "0805L050/12XR; rated voltage (at rated current I max)",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Maximum voltage, 0805L050/15XR",
"symbol": "V max",
"kind": "absolute_maximum",
"unit": "Vdc",
"min": null,
"typ": null,
"max": 15,
"conditions": "0805L050/15XR; rated voltage (at rated current I max)",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Maximum voltage, 0805L050/16XR",
"symbol": "V max",
"kind": "absolute_maximum",
"unit": "Vdc",
"min": null,
"typ": null,
"max": 16,
"conditions": "0805L050/16XR; rated voltage (at rated current I max)",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Maximum voltage, 0805L050/24XR",
"symbol": "V max",
"kind": "absolute_maximum",
"unit": "Vdc",
"min": null,
"typ": null,
"max": 24,
"conditions": "0805L050/24XR; rated voltage (at rated current I max)",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Maximum voltage, 0805L050/30AR",
"symbol": "V max",
"kind": "absolute_maximum",
"unit": "Vdc",
"min": null,
"typ": null,
"max": 30,
"conditions": "0805L050/30AR; rated voltage (at rated current I max)",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Maximum fault current",
"symbol": "I max",
"kind": "absolute_maximum",
"unit": "A",
"min": null,
"typ": null,
"max": 40,
"conditions": "0805L050 family; at rated voltage V max",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Power dissipated in tripped state, 6XR/12XR/15XR/16XR",
"symbol": "P d typ.",
"kind": "electrical",
"unit": "W",
"min": null,
"typ": 0.5,
"max": null,
"conditions": "0805L050/6XR, /12XR, /15XR, /16XR; typical, tripped state, 25 °C still air",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Power dissipated in tripped state, 24XR/30AR",
"symbol": "P d typ.",
"kind": "electrical",
"unit": "W",
"min": null,
"typ": 0.8,
"max": null,
"conditions": "0805L050/24XR, /30AR; typical, tripped state, 25 °C still air",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Maximum time to trip at assigned current",
"symbol": "T trip",
"kind": "timing",
"unit": "s",
"min": null,
"typ": null,
"max": 0.1,
"conditions": "0805L050 family; at 8.00 A (time to trip, max)",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Minimum initial resistance (un-soldered)",
"symbol": "R min",
"kind": "electrical",
"unit": "Ω",
"min": 0.1,
"typ": null,
"max": null,
"conditions": "0805L050 family; initial state before soldering",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Hold current derated at -40 °C ambient",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.68,
"conditions": "0805L050; ambient operating temperature -40 °C (derating table)",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Hold current derated at -20 °C ambient",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.62,
"conditions": "0805L050; ambient operating temperature -20 °C (derating table)",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Hold current derated at 0 °C ambient",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.55,
"conditions": "0805L050; ambient operating temperature 0 °C (derating table)",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Hold current derated at 25 °C ambient",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.5,
"conditions": "0805L050; ambient operating temperature 25 °C (derating table)",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Hold current derated at 40 °C ambient",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.4,
"conditions": "0805L050; ambient operating temperature 40 °C (derating table)",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Hold current derated at 50 °C ambient",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.37,
"conditions": "0805L050; ambient operating temperature 50 °C (derating table)",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Hold current derated at 60 °C ambient",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.33,
"conditions": "0805L050; ambient operating temperature 60 °C (derating table)",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Hold current derated at 70 °C ambient",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.29,
"conditions": "0805L050; ambient operating temperature 70 °C (derating table)",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Hold current derated at 85 °C ambient",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.23,
"conditions": "0805L050; ambient operating temperature 85 °C (derating table)",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Resistance change after passive aging",
"symbol": "",
"kind": "tolerance",
"unit": "%",
"min": -5,
"typ": null,
"max": 5,
"conditions": "+85 °C, 1000 hours; typical",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Resistance change after humidity aging",
"symbol": "",
"kind": "tolerance",
"unit": "%",
"min": -5,
"typ": null,
"max": 5,
"conditions": "+85 °C, 85 % R.H., 168 hours; typical",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Resistance change after thermal shock",
"symbol": "",
"kind": "tolerance",
"unit": "%",
"min": -33,
"typ": null,
"max": 33,
"conditions": "+85 °C to -40 °C, 20 times; typical",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Ambient operating temperature",
"symbol": "TA",
"kind": "recommended_operating",
"unit": "°C",
"min": -40,
"typ": null,
"max": 85,
"conditions": "Ambient operating conditions",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Maximum surface temperature in tripped state",
"symbol": "TSURF",
"kind": "thermal",
"unit": "°C",
"min": null,
"typ": null,
"max": 125,
"conditions": "Device in tripped state",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Storage temperature",
"symbol": "TSTORE",
"kind": "recommended_operating",
"unit": "°C",
"min": 0,
"typ": null,
"max": 30,
"conditions": "Storage condition, sealed packaging",
"source_page": 7,
"source": "datasheet"
},
{
"name": "Reflow peak temperature",
"symbol": "TP",
"kind": "thermal",
"unit": "°C",
"min": null,
"typ": null,
"max": 260,
"conditions": "Lead-free reflow; time within 5 °C of peak 20-40 s",
"source_page": 7,
"source": "datasheet"
}
]
}
},
"variants": [],
"sections": [
"hero",
"viewers",
"readme",
"breadcrumbs",
"info"
],
"discovery_triggers": [
"0805l050"
],
"discovery_pitch": "0805L050 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
"author": {
"name": "Ray"
},
"dependencies": {},
"hero": {
"type": "image",
"path": "docs/hero.png"
},
"files": [
"page.json",
"README.md",
"0805l050-30ar.kicad_sym",
"0805l050-30ar.kicad_mod",
"0805l050-30ar.glb",
"0805l050-30ar.step",
"0805l050-30ar.lbr",
"docs/hero.png",
"docs/0805l050-30ar-datasheet.pdf",
"viewers/symbol.html",
"viewers/footprint.html",
"0805l050-30ar-hero.glb",
"0805l050-30ar-hero.overlay.json"
],
"visibility": "public",
"description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",
"org": "adom"
}