package.json+372−2@@ -1,6 +1,6 @@ { "slug": "0805l050-30ar",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "tags": [@@ -210,5 +210,375 @@ "by": "factory/package_fit.py" } }- }+ },+ "title": "0805L050/30AR",+ "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "LUTE",+ "Package": "0805",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "21e79b52aaa8e9ead8f6ff764d7bfbed9e664190b0e90d7b103a5dcf4f847522",+ "rows": [+ {+ "name": "Hold current, 25 °C still air (0805L050 family)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.5,+ "conditions": "0805L050/6XR, /12XR, /15XR, /16XR, /24XR, /30AR; maximum current passed without tripping, 25 °C still air",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Trip current, 25 °C still air",+ "symbol": "I trip",+ "kind": "electrical",+ "unit": "A",+ "min": 1,+ "typ": null,+ "max": null,+ "conditions": "0805L050 family; minimum current at which device trips, 25 °C still air",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage, 0805L050/6XR",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "0805L050/6XR; rated voltage (at rated current I max)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage, 0805L050/12XR",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 12,+ "conditions": "0805L050/12XR; rated voltage (at rated current I max)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage, 0805L050/15XR",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 15,+ "conditions": "0805L050/15XR; rated voltage (at rated current I max)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage, 0805L050/16XR",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 16,+ "conditions": "0805L050/16XR; rated voltage (at rated current I max)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage, 0805L050/24XR",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 24,+ "conditions": "0805L050/24XR; rated voltage (at rated current I max)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage, 0805L050/30AR",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 30,+ "conditions": "0805L050/30AR; rated voltage (at rated current I max)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "0805L050 family; at rated voltage V max",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Power dissipated in tripped state, 6XR/12XR/15XR/16XR",+ "symbol": "P d typ.",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.5,+ "max": null,+ "conditions": "0805L050/6XR, /12XR, /15XR, /16XR; typical, tripped state, 25 °C still air",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Power dissipated in tripped state, 24XR/30AR",+ "symbol": "P d typ.",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.8,+ "max": null,+ "conditions": "0805L050/24XR, /30AR; typical, tripped state, 25 °C still air",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum time to trip at assigned current",+ "symbol": "T trip",+ "kind": "timing",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 0.1,+ "conditions": "0805L050 family; at 8.00 A (time to trip, max)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Minimum initial resistance (un-soldered)",+ "symbol": "R min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 0.1,+ "typ": null,+ "max": null,+ "conditions": "0805L050 family; initial state before soldering",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at -40 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.68,+ "conditions": "0805L050; ambient operating temperature -40 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at -20 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.62,+ "conditions": "0805L050; ambient operating temperature -20 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at 0 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.55,+ "conditions": "0805L050; ambient operating temperature 0 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at 25 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.5,+ "conditions": "0805L050; ambient operating temperature 25 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at 40 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.4,+ "conditions": "0805L050; ambient operating temperature 40 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at 50 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.37,+ "conditions": "0805L050; ambient operating temperature 50 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at 60 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.33,+ "conditions": "0805L050; ambient operating temperature 60 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at 70 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.29,+ "conditions": "0805L050; ambient operating temperature 70 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at 85 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.23,+ "conditions": "0805L050; ambient operating temperature 85 °C (derating table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Resistance change after passive aging",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85 °C, 1000 hours; typical",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Resistance change after humidity aging",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85 °C, 85 % R.H., 168 hours; typical",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Resistance change after thermal shock",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -33,+ "typ": null,+ "max": 33,+ "conditions": "+85 °C to -40 °C, 20 times; typical",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "Ambient operating conditions",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "TSURF",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "Device in tripped state",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "TSTORE",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 30,+ "conditions": "Storage condition, sealed packaging",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Reflow peak temperature",+ "symbol": "TP",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 260,+ "conditions": "Lead-free reflow; time within 5 °C of peak 20-40 s",+ "source_page": 7,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "0805l050"+ ],+ "discovery_pitch": "0805L050 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+5−5@@ -4,7 +4,7 @@ "slug": "0805l050-30ar", "title": "0805L050/30AR", "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -592,7 +592,7 @@ "0805l050-30ar-hero.glb", "0805l050-30ar-hero.overlay.json" ],- "visibility": {- "public": true- }-}+ "visibility": "public",+ "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "org": "adom"+}