main
Ray
Publish 0.1.0
db0732a
0805L030
LUTE · Resettable Fuses · 0805
0805L030 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Minimum resistance in initial (un-soldered) state | R min | 0.3 | Ω | Initial un-soldered state | 3 | ||
| Maximum resistance after trip or reflow | R 1max | 1.4 | Ω | 25 ℃, measured one hour after tripping or reflow soldering at 260 ℃ for 20 s | 3 | ||
| Hold current (maximum current without tripping) | I hold | 0.3 | A | 25 ℃ still air | 3 | ||
| Trip current (minimum current to trip) | I trip | 0.6 | A | 25 ℃ still air | 3 | ||
| Maximum fault current withstood at rated voltage | I max | 40 | A | At rated voltage V max | 3 | ||
| Maximum time to trip at assigned current | T trip | 0.1 | Sec | At 8.00 A test current | 3 | ||
| Ambient operating temperature | -40 | 85 | ℃ | Ambient operating conditions | 7 | ||
| Storage temperature | 0 | 30 | ℃ | Storage condition, 30%-60%RH | 10 | ||
| Maximum surface temperature in tripped state | 125 | ℃ | Device surface in tripped state | 7 | |||
| Peak reflow temperature | Tp | 260 | ℃ | Pb-free reflow peak temperature | 10 | ||
| Time within 5 ℃ of actual peak temperature | tp | 20 | 40 | Sec | Reflow, time within 5 ℃ of peak | 10 | |
| Power dissipated in tripped state | P d | 0.5 | W | Tripped state, 25 ℃ still air | 1 | ||
| Hold current at ambient -40 ℃ | I hold | 0.42 | A | Ambient operating temperature -40 ℃ | 8 | ||
| Hold current at ambient -20 ℃ | I hold | 0.38 | A | Ambient operating temperature -20 ℃ | 8 | ||
| Hold current at ambient 0 ℃ | I hold | 0.35 | A | Ambient operating temperature 0 ℃ | 8 | ||
| Hold current at ambient 25 ℃ | I hold | 0.3 | A | Ambient operating temperature 25 ℃ | 8 | ||
| Hold current at ambient 40 ℃ | I hold | 0.26 | A | Ambient operating temperature 40 ℃ | 8 | ||
| Hold current at ambient 50 ℃ | I hold | 0.21 | A | Ambient operating temperature 50 ℃ | 8 | ||
| Hold current at ambient 60 ℃ | I hold | 0.18 | A | Ambient operating temperature 60 ℃ | 8 | ||
| Hold current at ambient 70 ℃ | I hold | 0.15 | A | Ambient operating temperature 70 ℃ | 8 | ||
| Hold current at ambient 85 ℃ | I hold | 0.11 | A | Ambient operating temperature 85 ℃ | 8 |
CAD (KiCad official)
- Symbol:
0805L030 - Footprint:
Fuse:Fuse_0805_2012Metric - 3D model: 0805 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (13 pp, sha256
3bfb0bd2cb70f6cc, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).
# 0805L030
**LUTE** · Resettable Fuses · 0805
0805L030 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
## Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
## Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
## Electrical characteristics
Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Minimum resistance in initial (un-soldered) state | R min | 0.3 | | | Ω | Initial un-soldered state | 3 |
| Maximum resistance after trip or reflow | R 1max | | | 1.4 | Ω | 25 ℃, measured one hour after tripping or reflow soldering at 260 ℃ for 20 s | 3 |
| Hold current (maximum current without tripping) | I hold | | | 0.3 | A | 25 ℃ still air | 3 |
| Trip current (minimum current to trip) | I trip | 0.6 | | | A | 25 ℃ still air | 3 |
| Maximum fault current withstood at rated voltage | I max | | | 40 | A | At rated voltage V max | 3 |
| Maximum time to trip at assigned current | T trip | | | 0.1 | Sec | At 8.00 A test current | 3 |
| Ambient operating temperature | | -40 | | 85 | ℃ | Ambient operating conditions | 7 |
| Storage temperature | | 0 | | 30 | ℃ | Storage condition, 30%-60%RH | 10 |
| Maximum surface temperature in tripped state | | | | 125 | ℃ | Device surface in tripped state | 7 |
| Peak reflow temperature | Tp | | | 260 | ℃ | Pb-free reflow peak temperature | 10 |
| Time within 5 ℃ of actual peak temperature | tp | 20 | | 40 | Sec | Reflow, time within 5 ℃ of peak | 10 |
| Power dissipated in tripped state | P d | | 0.5 | | W | Tripped state, 25 ℃ still air | 1 |
| Hold current at ambient -40 ℃ | I hold | | 0.42 | | A | Ambient operating temperature -40 ℃ | 8 |
| Hold current at ambient -20 ℃ | I hold | | 0.38 | | A | Ambient operating temperature -20 ℃ | 8 |
| Hold current at ambient 0 ℃ | I hold | | 0.35 | | A | Ambient operating temperature 0 ℃ | 8 |
| Hold current at ambient 25 ℃ | I hold | | 0.3 | | A | Ambient operating temperature 25 ℃ | 8 |
| Hold current at ambient 40 ℃ | I hold | | 0.26 | | A | Ambient operating temperature 40 ℃ | 8 |
| Hold current at ambient 50 ℃ | I hold | | 0.21 | | A | Ambient operating temperature 50 ℃ | 8 |
| Hold current at ambient 60 ℃ | I hold | | 0.18 | | A | Ambient operating temperature 60 ℃ | 8 |
| Hold current at ambient 70 ℃ | I hold | | 0.15 | | A | Ambient operating temperature 70 ℃ | 8 |
| Hold current at ambient 85 ℃ | I hold | | 0.11 | | A | Ambient operating temperature 85 ℃ | 8 |
## CAD (KiCad official)
- Symbol: `0805L030`
- Footprint: `Fuse:Fuse_0805_2012Metric`
- 3D model: 0805 (KiCad packages3D, STEP)
## Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- **Datasheet:** [LUTE datasheet, copy hosted by LCSC](docs/0805l030-6xr-datasheet.pdf) (13 pp, sha256 `3bfb0bd2cb70f6cc`, retrieved 2026-11-20)
- **Extractor:** parts-factory `2.0.0` / `extract_pins`, primary `two-terminal convention` (convention), consensus `off` (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
- **CAD:** KiCad official libraries (CC-BY-SA 4.0).
[Datasheet PDF](docs/0805l030-6xr-datasheet.pdf)