Loads when you scroll to it. Unloads after 5 minutes in the background.

Symbol & Footprint

Schematic Symbol

Open full view ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.

PCB Footprint

Open full view ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.
Loads when you scroll to it. Unloads after 5 minutes in the background.
Download PDF
Contents

README

markdown

0805L030

LUTE · Resettable Fuses · 0805

0805L030 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0805
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Minimum resistance in initial (un-soldered) state R min 0.3 Ω Initial un-soldered state 3
Maximum resistance after trip or reflow R 1max 1.4 Ω 25 ℃, measured one hour after tripping or reflow soldering at 260 ℃ for 20 s 3
Hold current (maximum current without tripping) I hold 0.3 A 25 ℃ still air 3
Trip current (minimum current to trip) I trip 0.6 A 25 ℃ still air 3
Maximum fault current withstood at rated voltage I max 40 A At rated voltage V max 3
Maximum time to trip at assigned current T trip 0.1 Sec At 8.00 A test current 3
Ambient operating temperature -40 85 ℃ Ambient operating conditions 7
Storage temperature 0 30 ℃ Storage condition, 30%-60%RH 10
Maximum surface temperature in tripped state 125 ℃ Device surface in tripped state 7
Peak reflow temperature Tp 260 ℃ Pb-free reflow peak temperature 10
Time within 5 ℃ of actual peak temperature tp 20 40 Sec Reflow, time within 5 ℃ of peak 10
Power dissipated in tripped state P d 0.5 W Tripped state, 25 ℃ still air 1
Hold current at ambient -40 ℃ I hold 0.42 A Ambient operating temperature -40 ℃ 8
Hold current at ambient -20 ℃ I hold 0.38 A Ambient operating temperature -20 ℃ 8
Hold current at ambient 0 ℃ I hold 0.35 A Ambient operating temperature 0 ℃ 8
Hold current at ambient 25 ℃ I hold 0.3 A Ambient operating temperature 25 ℃ 8
Hold current at ambient 40 ℃ I hold 0.26 A Ambient operating temperature 40 ℃ 8
Hold current at ambient 50 ℃ I hold 0.21 A Ambient operating temperature 50 ℃ 8
Hold current at ambient 60 ℃ I hold 0.18 A Ambient operating temperature 60 ℃ 8
Hold current at ambient 70 ℃ I hold 0.15 A Ambient operating temperature 70 ℃ 8
Hold current at ambient 85 ℃ I hold 0.11 A Ambient operating temperature 85 ℃ 8

CAD (KiCad official)

  • Symbol: 0805L030
  • Footprint: Fuse:Fuse_0805_2012Metric
  • 3D model: 0805 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (13 pp, sha256 3bfb0bd2cb70f6cc, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF