main
Ray Publish 0.1.2 f581105
{
  "schema_version": 1,
  "type": "component",
  "slug": "0805l020-6xr",
  "title": "0805L020/6XR",
  "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",
  "version": "0.1.2",
  "license": "CC-BY-SA-4.0",
  "tags": [
    "component",
    "circuit protection",
    "0805l020",
    "factory-2.0.0",
    "extractor-text"
  ],
  "component": {
    "mpn": "0805L020/6XR",
    "manufacturer": "LUTE",
    "package": "0805",
    "pin_count": 2,
    "category": "Circuit Protection",
    "subcategory": "Resettable Fuses",
    "datasheet": "https://datasheet.lcsc.com/datasheet/pdf/9457b6038812528840b8867593922615.pdf",
    "parts": {
      "symbol": "0805l020-6xr.kicad_sym",
      "footprint": "0805l020-6xr.kicad_mod",
      "model_3d": "0805l020-6xr-hero.glb",
      "model_3d_step": "0805l020-6xr.step",
      "lbr": "0805l020-6xr.lbr",
      "model_3d_plain": "0805l020-6xr.glb"
    },
    "distributor_links": {
      "lcsc": "C47345569",
      "mouser": "576-0805L020"
    },
    "distributor_check": {
      "checked_at": "2026-11-20T16:30:37Z",
      "source": "Component Ocean /api/assign-pns",
      "digikey": {
        "pn": null,
        "status": "no match"
      },
      "mouser": {
        "pn": "576-0805L020",
        "status": "found"
      }
    },
    "pins": [
      {
        "number": "1",
        "name": "1",
        "type": "passive",
        "description": "Terminal 1 of an unpolarised fuse; either orientation."
      },
      {
        "number": "2",
        "name": "2",
        "type": "passive",
        "description": "Terminal 2 of an unpolarised fuse; either orientation."
      }
    ],
    "provenance": {
      "extractor": "extract_pins",
      "factory_chain": {
        "factory": "2.0.0",
        "extractor": "extract_pins",
        "primary_model": "two-terminal convention",
        "primary_mode": "convention",
        "consensus_model": null,
        "consensus": "agreed",
        "guards": "pin_guards 0.1: passed",
        "guard_notes": [
          "vision extraction: provenance cannot be text-verified; needs consensus"
        ],
        "pages_sent": 13,
        "cost_usd": 0.004,
        "at": "2026-11-20T16:30:32"
      },
      "datasheet": {
        "url": "https://datasheet.lcsc.com/datasheet/pdf/9457b6038812528840b8867593922615.pdf",
        "pages": 13,
        "sha256": "3bfb0bd2cb70f6cc",
        "source_tier": "lcsc",
        "citation": "LUTE datasheet, copy hosted by LCSC"
      },
      "cad": "KiCad official (CC-BY-SA 4.0)",
      "pins": {
        "total": 2,
        "described": 2,
        "cites_pages": true,
        "refuses_to_fabricate": true
      }
    },
    "viewers": {
      "symbol": "viewers/symbol.html",
      "footprint": "viewers/footprint.html"
    },
    "family": {
      "base": "0805l020-30xr",
      "base_mpn": "0805L020/30XR",
      "members": [
        {
          "slug": "0805l020-15xr",
          "mpn": "0805L020/15XR"
        },
        {
          "slug": "0805l020-16art",
          "mpn": "0805L020/16ART"
        },
        {
          "slug": "0805l020-24xr",
          "mpn": "0805L020/24XR"
        },
        {
          "slug": "0805l020-30xr",
          "mpn": "0805L020/30XR"
        },
        {
          "slug": "0805l020-33xr",
          "mpn": "0805L020/33XR"
        },
        {
          "slug": "0805l020-36xr",
          "mpn": "0805L020/36XR"
        },
        {
          "slug": "0805l020-6xr",
          "mpn": "0805L020/6XR"
        }
      ],
      "siblings": [
        "0805L020/15XR",
        "0805L020/16ART",
        "0805L020/24XR",
        "0805L020/30XR",
        "0805L020/33XR",
        "0805L020/36XR"
      ],
      "old_slug": "0805l020",
      "basis": "one family name (0805L020): the parts the cut-base page adom/0805l020 stood for (slug collision split, data/slug_collisions_2026-11-09.json)"
    },
    "models_3d": [
      {
        "file": "0805l020-6xr.step",
        "role": "plain",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          2,
          1.25,
          0.45
        ],
        "zmin_mm": 0,
        "centre_offset_mm": 0,
        "footprint_binding": "identity",
        "sha256": "bd29ccc62530d3bcfbbe078f12aac2a99ac75d01c043a2723a4bd36540aac146",
        "checked": "2026-11-20",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      }
    ],
    "package_dims": {
      "package_code": "0805",
      "source_page": 5,
      "D": {
        "nom_mm": 2.15,
        "range_mm": [
          2,
          2.3
        ]
      },
      "E1": {
        "nom_mm": 1.35,
        "range_mm": [
          1.2,
          1.5
        ]
      },
      "A": {
        "nom_mm": 0.5,
        "range_mm": [
          0.5,
          null
        ]
      },
      "source": "datasheet package drawing, every number found on its page (extract_pins --task dims)",
      "model_check": {
        "file": "0805l020-6xr.step",
        "verdict": "PASS",
        "reasons": [
          "height within the datasheet's package drawing"
        ],
        "by": "factory/package_fit.py"
      }
    }
  },
  "metadata": {
    "specs": {
      "Manufacturer": "LUTE",
      "Package": "0805",
      "Category": "Circuit Protection",
      "Pins": "2"
    },
    "characteristics": {
      "version": 1,
      "source": "datasheet",
      "datasheet_sha256": "3bfb0bd2cb70f6cc006ce996cc7d816f51c1a908f76d95a653c2323daa150a6e",
      "rows": [
        {
          "name": "Resistance after tripping or reflow (R1max)",
          "symbol": "R 1max",
          "kind": "electrical",
          "unit": "Ω",
          "min": null,
          "typ": null,
          "max": 3.5,
          "conditions": "25℃, measured one hour after tripping or reflow soldering at 260℃ for 20 s; same value for all 0805L020 variants",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Minimum initial resistance (un-soldered)",
          "symbol": "R min",
          "kind": "electrical",
          "unit": "Ω",
          "min": 0.5,
          "typ": null,
          "max": null,
          "conditions": "Initial un-soldered state; same value for all 0805L020 variants",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Trip current",
          "symbol": "I trip",
          "kind": "electrical",
          "unit": "A",
          "min": 0.5,
          "typ": null,
          "max": null,
          "conditions": "25℃ still air; minimum current at which the device trips",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Hold current",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.2,
          "conditions": "25℃ still air; maximum current the device passes without tripping",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Maximum fault current",
          "symbol": "I max",
          "kind": "absolute_maximum",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 40,
          "conditions": "At rated voltage (V max) of the specific variant; same value for all 0805L020 variants",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Maximum time to trip",
          "symbol": "T trip",
          "kind": "timing",
          "unit": "s",
          "min": null,
          "typ": null,
          "max": 0.02,
          "conditions": "At 8.00 A test current; same value for all 0805L020 variants",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Power dissipated in tripped state",
          "symbol": "P d",
          "kind": "electrical",
          "unit": "W",
          "min": null,
          "typ": 0.5,
          "max": null,
          "conditions": "Tripped state, 25℃ still air",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Hold current at ambient -40℃",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.28,
          "conditions": "Temperature derating table, ambient -40℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current at ambient -20℃",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.25,
          "conditions": "Temperature derating table, ambient -20℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current at ambient 0℃",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.23,
          "conditions": "Temperature derating table, ambient 0℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current at ambient 25℃",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.2,
          "conditions": "Temperature derating table, ambient 25℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current at ambient 40℃",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.17,
          "conditions": "Temperature derating table, ambient 40℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current at ambient 50℃",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.14,
          "conditions": "Temperature derating table, ambient 50℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current at ambient 60℃",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.12,
          "conditions": "Temperature derating table, ambient 60℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current at ambient 70℃",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.1,
          "conditions": "Temperature derating table, ambient 70℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current at ambient 85℃",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.07,
          "conditions": "Temperature derating table, ambient 85℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Ambient operating temperature",
          "symbol": "TA",
          "kind": "recommended_operating",
          "unit": "°C",
          "min": -40,
          "typ": null,
          "max": 85,
          "conditions": "Ambient operating conditions for the 0805L series",
          "source_page": 7,
          "source": "datasheet"
        },
        {
          "name": "Maximum surface temperature in tripped state",
          "symbol": "",
          "kind": "thermal",
          "unit": "°C",
          "min": null,
          "typ": null,
          "max": 125,
          "conditions": "Device in the tripped state",
          "source_page": 7,
          "source": "datasheet"
        },
        {
          "name": "Storage temperature",
          "symbol": "TSTORE",
          "kind": "recommended_operating",
          "unit": "°C",
          "min": 0,
          "typ": null,
          "max": 30,
          "conditions": "Storage condition, 30%-60%RH, sealed packaging",
          "source_page": 10,
          "source": "datasheet"
        }
      ]
    }
  },
  "variants": [],
  "sections": [
    "hero",
    "viewers",
    "readme",
    "breadcrumbs",
    "info"
  ],
  "discovery_triggers": [
    "0805l020"
  ],
  "discovery_pitch": "0805L020 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
  "author": {
    "name": "Ray"
  },
  "dependencies": {},
  "hero": {
    "type": "image",
    "path": "docs/hero.png"
  },
  "files": [
    "page.json",
    "README.md",
    "0805l020-6xr.kicad_sym",
    "0805l020-6xr.kicad_mod",
    "0805l020-6xr.glb",
    "0805l020-6xr.step",
    "0805l020-6xr.lbr",
    "docs/hero.png",
    "docs/0805l020-6xr-datasheet.pdf",
    "viewers/symbol.html",
    "viewers/footprint.html",
    "0805l020-6xr-hero.glb",
    "0805l020-6xr-hero.overlay.json"
  ],
  "visibility": "public",
  "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",
  "org": "adom"
}