main
Download ZIP Propose a change
Made with kicad-footprint-generator 10.0 · KiCad file format 20260206
Name Last commit message Last updated
docs Publish 0.1.0 · Ray
viewers 0805l020-6xr: viewers · Ray
0805l020-6xr-hero.glb Publish 0.1.0 · Ray
0805l020-6xr-hero.overlay.json Publish 0.1.0 · Ray
0805l020-6xr.glb Publish 0.1.0 · Ray
0805l020-6xr.kicad_mod Publish 0.1.0 · Ray
0805l020-6xr.kicad_sym Publish 0.1.0 · Ray
0805l020-6xr.lbr Publish 0.1.0 · Ray
0805l020-6xr.step Publish 0.1.0 · Ray
package.json Publish 0.1.2 · Ray
page.json Publish 0.1.2 · Ray
README.md Publish 0.1.0 · Ray
verification.json Verified: Published by the parts factory: tier lcsc, 2 pins · Ray

0805L020

LUTE · Resettable Fuses · 0805

0805L020 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0805
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Resistance after tripping or reflow (R1max) R 1max 3.5 Ω 25℃, measured one hour after tripping or reflow soldering at 260℃ for 20 s; same value for all 0805L020 variants 2
Minimum initial resistance (un-soldered) R min 0.5 Ω Initial un-soldered state; same value for all 0805L020 variants 2
Trip current I trip 0.5 A 25℃ still air; minimum current at which the device trips 2
Hold current I hold 0.2 A 25℃ still air; maximum current the device passes without tripping 2
Maximum fault current I max 40 A At rated voltage (V max) of the specific variant; same value for all 0805L020 variants 2
Maximum time to trip T trip 0.02 s At 8.00 A test current; same value for all 0805L020 variants 2
Power dissipated in tripped state P d 0.5 W Tripped state, 25℃ still air 2
Hold current at ambient -40℃ I hold 0.28 A Temperature derating table, ambient -40℃ 8
Hold current at ambient -20℃ I hold 0.25 A Temperature derating table, ambient -20℃ 8
Hold current at ambient 0℃ I hold 0.23 A Temperature derating table, ambient 0℃ 8
Hold current at ambient 25℃ I hold 0.2 A Temperature derating table, ambient 25℃ 8
Hold current at ambient 40℃ I hold 0.17 A Temperature derating table, ambient 40℃ 8
Hold current at ambient 50℃ I hold 0.14 A Temperature derating table, ambient 50℃ 8
Hold current at ambient 60℃ I hold 0.12 A Temperature derating table, ambient 60℃ 8
Hold current at ambient 70℃ I hold 0.1 A Temperature derating table, ambient 70℃ 8
Hold current at ambient 85℃ I hold 0.07 A Temperature derating table, ambient 85℃ 8
Ambient operating temperature TA -40 85 °C Ambient operating conditions for the 0805L series 7
Maximum surface temperature in tripped state 125 °C Device in the tripped state 7
Storage temperature TSTORE 0 30 °C Storage condition, 30%-60%RH, sealed packaging 10

CAD (KiCad official)

  • Symbol: 0805L020
  • Footprint: Fuse:Fuse_0805_2012Metric
  • 3D model: 0805 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (13 pp, sha256 3bfb0bd2cb70f6cc, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF