Made with kicad-footprint-generator 10.0 · KiCad file format 20260206
0805L020
LUTE · Resettable Fuses · 0805
0805L020 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Resistance after tripping or reflow (R1max) | R 1max | 3.5 | Ω | 25℃, measured one hour after tripping or reflow soldering at 260℃ for 20 s; same value for all 0805L020 variants | 2 | ||
| Minimum initial resistance (un-soldered) | R min | 0.5 | Ω | Initial un-soldered state; same value for all 0805L020 variants | 2 | ||
| Trip current | I trip | 0.5 | A | 25℃ still air; minimum current at which the device trips | 2 | ||
| Hold current | I hold | 0.2 | A | 25℃ still air; maximum current the device passes without tripping | 2 | ||
| Maximum fault current | I max | 40 | A | At rated voltage (V max) of the specific variant; same value for all 0805L020 variants | 2 | ||
| Maximum time to trip | T trip | 0.02 | s | At 8.00 A test current; same value for all 0805L020 variants | 2 | ||
| Power dissipated in tripped state | P d | 0.5 | W | Tripped state, 25℃ still air | 2 | ||
| Hold current at ambient -40℃ | I hold | 0.28 | A | Temperature derating table, ambient -40℃ | 8 | ||
| Hold current at ambient -20℃ | I hold | 0.25 | A | Temperature derating table, ambient -20℃ | 8 | ||
| Hold current at ambient 0℃ | I hold | 0.23 | A | Temperature derating table, ambient 0℃ | 8 | ||
| Hold current at ambient 25℃ | I hold | 0.2 | A | Temperature derating table, ambient 25℃ | 8 | ||
| Hold current at ambient 40℃ | I hold | 0.17 | A | Temperature derating table, ambient 40℃ | 8 | ||
| Hold current at ambient 50℃ | I hold | 0.14 | A | Temperature derating table, ambient 50℃ | 8 | ||
| Hold current at ambient 60℃ | I hold | 0.12 | A | Temperature derating table, ambient 60℃ | 8 | ||
| Hold current at ambient 70℃ | I hold | 0.1 | A | Temperature derating table, ambient 70℃ | 8 | ||
| Hold current at ambient 85℃ | I hold | 0.07 | A | Temperature derating table, ambient 85℃ | 8 | ||
| Ambient operating temperature | TA | -40 | 85 | °C | Ambient operating conditions for the 0805L series | 7 | |
| Maximum surface temperature in tripped state | 125 | °C | Device in the tripped state | 7 | |||
| Storage temperature | TSTORE | 0 | 30 | °C | Storage condition, 30%-60%RH, sealed packaging | 10 |
CAD (KiCad official)
- Symbol:
0805L020 - Footprint:
Fuse:Fuse_0805_2012Metric - 3D model: 0805 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (13 pp, sha256
3bfb0bd2cb70f6cc, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).