Key specifications

Parameter Value
Manufacturer LUTE
Package 0805
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Trip current (minimum) I trip 0.5 A 25°C still air; minimum current at which the device trips 2
Maximum fault current I max 40 A at rated voltage (V max) 2
Maximum time to trip T trip 0.02 s at 8.00 A assigned current 2
Minimum initial resistance R min 0.5 Ω initial, un-soldered state 2
Maximum resistance after trip or reflow R 1max 3.5 Ω 25°C, measured one hour after tripping or 260°C reflow for 20 s 2
Ambient operating temperature -40 85 °C ambient operating conditions 5
Storage temperature 0 30 °C storage condition, 30%-60% RH 7
Maximum surface temperature in tripped state 125 °C device in tripped state 5
Hold current I hold 0.2 A 25°C still air; maximum current device passes without tripping 2
Power dissipated when tripped P d 0.5 W tripped state, 25°C still air 2
Hold current at -40 °C ambient I hold 0.28 A ambient operating temperature -40 °C 6
Hold current at -20 °C ambient I hold 0.25 A ambient operating temperature -20 °C 6
Hold current at 0 °C ambient I hold 0.23 A ambient operating temperature 0 °C 6
Hold current at 25 °C ambient I hold 0.2 A ambient operating temperature 25 °C 6
Hold current at 40 °C ambient I hold 0.17 A ambient operating temperature 40 °C 6
Hold current at 50 °C ambient I hold 0.14 A ambient operating temperature 50 °C 6
Hold current at 60 °C ambient I hold 0.12 A ambient operating temperature 60 °C 6
Hold current at 70 °C ambient I hold 0.1 A ambient operating temperature 70 °C 6
Hold current at 85 °C ambient I hold 0.07 A ambient operating temperature 85 °C 6

CAD (KiCad official)

  • Symbol: 0805L020
  • Footprint: Fuse:Fuse_0805_2012Metric
  • 3D model: 0805 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (10 pp, sha256 72b500408f6e5c0f, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).