3D Model
Open in new tab ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.
Symbol & Footprint
Schematic Symbol
Open full view ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
PCB Footprint
Open full view ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
Datasheet
Open in new tab ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
README
markdown0805L020
LUTE · Resettable Fuses · 0805
0805L020 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Trip current (minimum) | I trip | 0.5 | A | 25°C still air; minimum current at which the device trips | 2 | ||
| Maximum fault current | I max | 40 | A | at rated voltage (V max) | 2 | ||
| Maximum time to trip | T trip | 0.02 | s | at 8.00 A assigned current | 2 | ||
| Minimum initial resistance | R min | 0.5 | Ω | initial, un-soldered state | 2 | ||
| Maximum resistance after trip or reflow | R 1max | 3.5 | Ω | 25°C, measured one hour after tripping or 260°C reflow for 20 s | 2 | ||
| Ambient operating temperature | -40 | 85 | °C | ambient operating conditions | 5 | ||
| Storage temperature | 0 | 30 | °C | storage condition, 30%-60% RH | 7 | ||
| Maximum surface temperature in tripped state | 125 | °C | device in tripped state | 5 | |||
| Hold current | I hold | 0.2 | A | 25°C still air; maximum current device passes without tripping | 2 | ||
| Power dissipated when tripped | P d | 0.5 | W | tripped state, 25°C still air | 2 | ||
| Hold current at -40 °C ambient | I hold | 0.28 | A | ambient operating temperature -40 °C | 6 | ||
| Hold current at -20 °C ambient | I hold | 0.25 | A | ambient operating temperature -20 °C | 6 | ||
| Hold current at 0 °C ambient | I hold | 0.23 | A | ambient operating temperature 0 °C | 6 | ||
| Hold current at 25 °C ambient | I hold | 0.2 | A | ambient operating temperature 25 °C | 6 | ||
| Hold current at 40 °C ambient | I hold | 0.17 | A | ambient operating temperature 40 °C | 6 | ||
| Hold current at 50 °C ambient | I hold | 0.14 | A | ambient operating temperature 50 °C | 6 | ||
| Hold current at 60 °C ambient | I hold | 0.12 | A | ambient operating temperature 60 °C | 6 | ||
| Hold current at 70 °C ambient | I hold | 0.1 | A | ambient operating temperature 70 °C | 6 | ||
| Hold current at 85 °C ambient | I hold | 0.07 | A | ambient operating temperature 85 °C | 6 |
CAD (KiCad official)
- Symbol:
0805L020 - Footprint:
Fuse:Fuse_0805_2012Metric - 3D model: 0805 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (10 pp, sha256
72b500408f6e5c0f, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).