123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519
{
"schema_version": 1,
"type": "component",
"slug": "0805l010-60wr",
"title": "0805L010/60WR",
"brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",
"version": "0.1.2",
"license": "CC-BY-SA-4.0",
"tags": [
"component",
"circuit protection",
"0805l010",
"factory-2.0.0",
"extractor-text"
],
"component": {
"mpn": "0805L010/60WR",
"manufacturer": "LUTE",
"package": "0805",
"pin_count": 2,
"category": "Circuit Protection",
"subcategory": "Resettable Fuses",
"datasheet": "https://datasheet.lcsc.com/datasheet/pdf/20632ce9016fa66bc9d4f91eb7ceaea6.pdf",
"parts": {
"symbol": "0805l010-60wr.kicad_sym",
"footprint": "0805l010-60wr.kicad_mod",
"model_3d": "0805l010-60wr-hero.glb",
"model_3d_step": "0805l010-60wr.step",
"lbr": "0805l010-60wr.lbr",
"model_3d_plain": "0805l010-60wr.glb"
},
"distributor_links": {
"lcsc": "C22435897"
},
"distributor_check": {
"checked_at": "2026-11-20T16:10:23Z",
"source": "Component Ocean /api/assign-pns",
"digikey": {
"pn": null,
"status": "no match"
},
"mouser": {
"pn": null,
"status": "no match"
}
},
"pins": [
{
"number": "1",
"name": "1",
"type": "passive",
"description": "Terminal 1 of an unpolarised fuse; either orientation."
},
{
"number": "2",
"name": "2",
"type": "passive",
"description": "Terminal 2 of an unpolarised fuse; either orientation."
}
],
"provenance": {
"extractor": "extract_pins",
"factory_chain": {
"factory": "2.0.0",
"extractor": "extract_pins",
"primary_model": "two-terminal convention",
"primary_mode": "convention",
"consensus_model": null,
"consensus": "agreed",
"guards": "pin_guards 0.1: passed",
"guard_notes": [
"vision extraction: provenance cannot be text-verified; needs consensus"
],
"pages_sent": 11,
"cost_usd": 0.0033,
"at": "2026-11-20T16:10:17"
},
"datasheet": {
"url": "https://datasheet.lcsc.com/datasheet/pdf/20632ce9016fa66bc9d4f91eb7ceaea6.pdf",
"pages": 11,
"sha256": "e36ae86f7fa4ccdf",
"source_tier": "lcsc",
"citation": "LUTE datasheet, copy hosted by LCSC"
},
"cad": "KiCad official (CC-BY-SA 4.0)",
"pins": {
"total": 2,
"described": 2,
"cites_pages": true,
"refuses_to_fabricate": true
}
},
"viewers": {
"symbol": "viewers/symbol.html",
"footprint": "viewers/footprint.html"
},
"family": {
"base": "0805l010-24xr",
"base_mpn": "0805L010/24XR",
"members": [
{
"slug": "0805l010-15xr",
"mpn": "0805L010/15XR"
},
{
"slug": "0805l010-16xrt",
"mpn": "0805L010/16XRT"
},
{
"slug": "0805l010-24xr",
"mpn": "0805L010/24XR"
},
{
"slug": "0805l010-33ar",
"mpn": "0805L010/33AR"
},
{
"slug": "0805l010-48ar",
"mpn": "0805L010/48AR"
},
{
"slug": "0805l010-60wr",
"mpn": "0805L010/60WR"
},
{
"slug": "0805l010-6xr",
"mpn": "0805L010/6XR"
},
{
"slug": "0805l010-9xr",
"mpn": "0805L010/9XR"
}
],
"siblings": [
"0805L010/15XR",
"0805L010/16XRT",
"0805L010/24XR",
"0805L010/33AR",
"0805L010/48AR",
"0805L010/6XR",
"0805L010/9XR"
],
"old_slug": "0805l010",
"basis": "one family name (0805L010): the parts the cut-base page adom/0805l010 stood for (slug collision split, data/slug_collisions_2026-11-09.json)"
},
"models_3d": [
{
"file": "0805l010-60wr.step",
"role": "plain",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
2,
1.25,
0.45
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "bd29ccc62530d3bcfbbe078f12aac2a99ac75d01c043a2723a4bd36540aac146",
"checked": "2026-11-20",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
}
],
"package_dims": {
"package_code": "0805",
"source_page": 4,
"D": {
"nom_mm": 2.15,
"range_mm": [
2,
2.3
]
},
"E1": {
"nom_mm": 1.35,
"range_mm": [
1.2,
1.5
]
},
"A": {
"nom_mm": 0.65,
"range_mm": [
0.4,
0.9
]
},
"source": "datasheet package drawing, every number found on its page (extract_pins --task dims)",
"model_check": {
"file": "0805l010-60wr.step",
"verdict": "PASS",
"reasons": [
"height within the datasheet's package drawing"
],
"by": "factory/package_fit.py"
}
}
},
"metadata": {
"specs": {
"Manufacturer": "LUTE",
"Package": "0805",
"Category": "Circuit Protection",
"Pins": "2"
},
"characteristics": {
"version": 1,
"source": "datasheet",
"datasheet_sha256": "e36ae86f7fa4ccdf109f2a4cb1550eedfd560229695057f6d0476eb27b3a642c",
"rows": [
{
"name": "Hold current (maximum, device passes without tripping)",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.1,
"conditions": "25°C still air",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Trip current (minimum, device trips)",
"symbol": "I trip",
"kind": "electrical",
"unit": "A",
"min": 0.3,
"typ": null,
"max": null,
"conditions": "25°C still air",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Minimum resistance, initial un-soldered",
"symbol": "R min",
"kind": "electrical",
"unit": "Ω",
"min": 0.75,
"typ": null,
"max": null,
"conditions": "initial, un-soldered state",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Maximum resistance after trip or reflow",
"symbol": "R1max",
"kind": "electrical",
"unit": "Ω",
"min": null,
"typ": null,
"max": 6,
"conditions": "25°C, measured 1 h after tripping or 260°C reflow for 20 s (/60WR: 8.000 Ω)",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Maximum time to trip",
"symbol": "",
"kind": "timing",
"unit": "s",
"min": null,
"typ": null,
"max": 1.5,
"conditions": "at 0.50 A (5× hold current)",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Derated hold current at ambient -40 °C",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.14,
"conditions": "ambient -40 °C",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Derated hold current at ambient -20 °C",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.12,
"conditions": "ambient -20 °C",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Derated hold current at ambient 0 °C",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.11,
"conditions": "ambient 0 °C",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Derated hold current at ambient 25 °C",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.1,
"conditions": "ambient 25 °C",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Derated hold current at ambient 40 °C",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.08,
"conditions": "ambient 40 °C",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Derated hold current at ambient 50 °C",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.07,
"conditions": "ambient 50 °C",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Derated hold current at ambient 60 °C",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.06,
"conditions": "ambient 60 °C",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Derated hold current at ambient 70 °C",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.05,
"conditions": "ambient 70 °C",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Derated hold current at ambient 85 °C",
"symbol": "I hold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.03,
"conditions": "ambient 85 °C",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Resistance change, passive aging",
"symbol": "",
"kind": "tolerance",
"unit": "%",
"min": -5,
"typ": null,
"max": 5,
"conditions": "+85°C, 1000 hours (typical)",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Resistance change, humidity aging",
"symbol": "",
"kind": "tolerance",
"unit": "%",
"min": -5,
"typ": null,
"max": 5,
"conditions": "+85°C, 85% R.H., 168 hours (typical)",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Resistance change, thermal shock",
"symbol": "",
"kind": "tolerance",
"unit": "%",
"min": -33,
"typ": null,
"max": 33,
"conditions": "+85°C to -40°C, 20 times (typical)",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Ambient operating temperature",
"symbol": "TA",
"kind": "recommended_operating",
"unit": "°C",
"min": -40,
"typ": null,
"max": 85,
"conditions": "ambient operating conditions",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Maximum surface temperature in tripped state",
"symbol": "",
"kind": "thermal",
"unit": "°C",
"min": null,
"typ": null,
"max": 125,
"conditions": "device in tripped state",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Storage temperature",
"symbol": "",
"kind": "recommended_operating",
"unit": "°C",
"min": 0,
"typ": null,
"max": 30,
"conditions": "storage at 30%-60% RH",
"source_page": 8,
"source": "datasheet"
},
{
"name": "Reflow peak temperature",
"symbol": "Tp",
"kind": "thermal",
"unit": "°C",
"min": null,
"typ": null,
"max": 260,
"conditions": "reflow; time within 5°C of peak 20-40 s",
"source_page": 8,
"source": "datasheet"
},
{
"name": "Power dissipated in tripped state",
"symbol": "Pd",
"kind": "electrical",
"unit": "W",
"min": null,
"typ": 0.5,
"max": null,
"conditions": "tripped state, 25°C still air",
"source_page": 1,
"source": "datasheet"
}
]
}
},
"variants": [],
"sections": [
"hero",
"viewers",
"readme",
"breadcrumbs",
"info"
],
"discovery_triggers": [
"0805l010"
],
"discovery_pitch": "0805L010 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
"author": {
"name": "Ray"
},
"dependencies": {},
"hero": {
"type": "image",
"path": "docs/hero.png"
},
"files": [
"page.json",
"README.md",
"0805l010-60wr.kicad_sym",
"0805l010-60wr.kicad_mod",
"0805l010-60wr.glb",
"0805l010-60wr.step",
"0805l010-60wr.lbr",
"docs/hero.png",
"docs/0805l010-60wr-datasheet.pdf",
"viewers/symbol.html",
"viewers/footprint.html",
"0805l010-60wr-hero.glb",
"0805l010-60wr-hero.overlay.json"
],
"visibility": "public",