Made with kicad-footprint-generator 10.0 · KiCad file format 20260206
0805L010
LUTE · Resettable Fuses · 0805
0805L010 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Hold current (maximum, device passes without tripping) | I hold | 0.1 | A | 25°C still air | 1 | ||
| Trip current (minimum, device trips) | I trip | 0.3 | A | 25°C still air | 1 | ||
| Minimum resistance, initial un-soldered | R min | 0.75 | Ω | initial, un-soldered state | 1 | ||
| Maximum resistance after trip or reflow | R1max | 6 | Ω | 25°C, measured 1 h after tripping or 260°C reflow for 20 s (/60WR: 8.000 Ω) | 1 | ||
| Maximum time to trip | 1.5 | s | at 0.50 A (5× hold current) | 1 | |||
| Derated hold current at ambient -40 °C | I hold | 0.14 | A | ambient -40 °C | 6 | ||
| Derated hold current at ambient -20 °C | I hold | 0.12 | A | ambient -20 °C | 6 | ||
| Derated hold current at ambient 0 °C | I hold | 0.11 | A | ambient 0 °C | 6 | ||
| Derated hold current at ambient 25 °C | I hold | 0.1 | A | ambient 25 °C | 6 | ||
| Derated hold current at ambient 40 °C | I hold | 0.08 | A | ambient 40 °C | 6 | ||
| Derated hold current at ambient 50 °C | I hold | 0.07 | A | ambient 50 °C | 6 | ||
| Derated hold current at ambient 60 °C | I hold | 0.06 | A | ambient 60 °C | 6 | ||
| Derated hold current at ambient 70 °C | I hold | 0.05 | A | ambient 70 °C | 6 | ||
| Derated hold current at ambient 85 °C | I hold | 0.03 | A | ambient 85 °C | 6 | ||
| Resistance change, passive aging | -5 | 5 | % | +85°C, 1000 hours (typical) | 6 | ||
| Resistance change, humidity aging | -5 | 5 | % | +85°C, 85% R.H., 168 hours (typical) | 6 | ||
| Resistance change, thermal shock | -33 | 33 | % | +85°C to -40°C, 20 times (typical) | 6 | ||
| Ambient operating temperature | TA | -40 | 85 | °C | ambient operating conditions | 6 | |
| Maximum surface temperature in tripped state | 125 | °C | device in tripped state | 6 | |||
| Storage temperature | 0 | 30 | °C | storage at 30%-60% RH | 8 | ||
| Reflow peak temperature | Tp | 260 | °C | reflow; time within 5°C of peak 20-40 s | 8 | ||
| Power dissipated in tripped state | Pd | 0.5 | W | tripped state, 25°C still air | 1 |
CAD (KiCad official)
- Symbol:
0805L010 - Footprint:
Fuse:Fuse_0805_2012Metric - 3D model: 0805 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (11 pp, sha256
e36ae86f7fa4ccdf, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).