123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334
{
"schema_version": 1,
"type": "component",
"slug": "0215001-mxp",
"title": "0215001.MXP",
"brief": "Littelfuse Disposable Fuses, D5.2xL20mm. Pinout settled in review by an AI reviewer against the manufacturer's datasheet, KiCad symbol/footprint/3D.",
"version": "0.1.1",
"license": "CC-BY-SA-4.0",
"tags": [
"component",
"circuit protection",
"0215001.mxp",
"factory-2.0.0",
"extractor-text"
],
"component": {
"mpn": "0215001.MXP",
"land_source": "datasheet",
"land_note": "LAND CHOICE (task master 2026-11-17): 0215001.MXP is a 5 x 20 mm cartridge fuse with no leads; the land is a pair of Littelfuse 111 PCB fuse clips (111 501, ordering PN 01110501Z). Littelfuse 111 Series datasheet (rev. GD 01/31/23) 'Recommended Mounting Dimensions' for 111 501/111 506: two holes per clip 5.0 +.076/-.025 apart across the fuse axis, hole dia 1.17 (.046 in); clip-to-clip 'B' = .74 in for 5x20 (Table 1) = 18.8 mm along the fuse axis. Pad copper is not printed: 2.2 mm round pads (derived, 0.5 mm annular ring on the 1.17 drill). KiCad Fuseholder_Clip-5x20mm_Littelfuse_111_Inline_P20.00x5.00mm puts each clip's two holes along the fuse axis (pads at 0/5 and 15/20), which does not match this drawing, so the land is explicit. Body = the cartridge only (fuse sheet: 20 +/-0.5 long, 5.2 dia); height 6.86 = Table 1 'A' .27 in, the fuse top with the fuse in place. Page note: cartridge fuse, no leads; land is a pair of Littelfuse 111 PCB clips; use a holder instead if preferred.",
"manufacturer": "Littelfuse",
"package": "D5.2xL20mm",
"pin_count": 2,
"category": "Circuit Protection",
"subcategory": "Disposable Fuses",
"datasheet": "https://www.littelfuse.com/assetdocs/fuse-215-datasheet?assetguid=990F7193-D9A2-48E4-B760-2B43514249CF",
"parts": {
"symbol": "0215001-mxp.kicad_sym",
"footprint": "0215001-mxp.kicad_mod",
"model_3d": "0215001-mxp-hero.glb",
"model_3d_step": "0215001-mxp.step",
"lbr": "0215001-mxp.lbr",
"model_3d_plain": "0215001-mxp.glb"
},
"distributor_links": {
"lcsc": "C142715",
"digikey": "F1696-ND",
"mouser": "576-0215001.MXP"
},
"distributor_check": {
"checked_at": "2026-11-17T16:08:38Z",
"source": "Component Ocean /api/assign-pns",
"digikey": {
"pn": "F1696-ND",
"status": "found"
},
"mouser": {
"pn": "576-0215001.MXP",
"status": "found"
}
},
"pins": [
{
"number": "1",
"name": "1",
"type": "passive",
"description": "Fuse end cap (non-polar; Littelfuse prints no terminal names)"
},
{
"number": "2",
"name": "2",
"type": "passive",
"description": "Fuse end cap (non-polar; Littelfuse prints no terminal names)"
}
],
"provenance": {
"extractor": "ds2sf",
"datasheet": {
"url": "https://www.littelfuse.com/assetdocs/fuse-215-datasheet?assetguid=990F7193-D9A2-48E4-B760-2B43514249CF",
"pages": 4,
"sha256": "6ea4fed8f791e769",
"source_tier": "mfr"
},
"cad": "Adom_Gen derived land; symbol and 3D generated",
"pins": {
"total": 2,
"described": 2,
"cites_pages": true,
"refuses_to_fabricate": true
}
},
"viewers": {
"symbol": "viewers/symbol.html",
"footprint": "viewers/footprint.html"
},
"models_3d": [
{
"file": "0215001-mxp.step",
"role": "plain",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "body on z = 0, through-hole leads below",
"extents_mm": [
20,
5.2,
5.2
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "2eede412f9995aef0fad9dd9e7ef1053a93cf365f7669e5c0d95adb7e7cc0f69",
"checked": "2026-11-17",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
},
{
"file": "0215001-mxp-etched.step",
"role": "eda",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "body on z = 0, through-hole leads below",
"extents_mm": [
20,
5.2,
5.2
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "2eede412f9995aef0fad9dd9e7ef1053a93cf365f7669e5c0d95adb7e7cc0f69",
"checked": "2026-11-17",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
}
]
},
"metadata": {
"specs": {
"Manufacturer": "Littelfuse",
"Package": "D5.2xL20mm",
"Category": "Circuit Protection",
"Pins": "2"
},
"appearance": {
"contacts": {
"quote": "Leads: Tin–plated Copper",
"page": 2,
"doc": "ds.pdf",
"material": "Copper",
"plating": "tin"
},
"version": 1,
"datasheet_sha256": "6ea4fed8f791e7697f49e1c76c71065a72a87f92652b79b6565833ac9c7c5651"
},
"characteristics": {
"version": 1,
"source": "datasheet",
"datasheet_sha256": "6ea4fed8f791e7697f49e1c76c71065a72a87f92652b79b6565833ac9c7c5651",
"rows": [
{
"name": "Opening time at 150% of rating",
"symbol": "",
"kind": "electrical",
"unit": "minutes",
"min": 60,
"typ": null,
"max": null,
"conditions": "150% of ampere rating, 1A-3.15A",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Opening time at 210% of rating",
"symbol": "",
"kind": "electrical",
"unit": "minutes",
"min": null,
"typ": null,
"max": 30,
"conditions": "210% of ampere rating, 1A-3.15A",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Opening time at 275% of rating",
"symbol": "",
"kind": "electrical",
"unit": "sec",
"min": 0.75,
"typ": null,
"max": 80,
"conditions": "275% of ampere rating, 1A-3.15A",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Opening time at 400% of rating",
"symbol": "",
"kind": "electrical",
"unit": "sec",
"min": 0.095,
"typ": null,
"max": 5,
"conditions": "400% of ampere rating, 1A-3.15A",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Opening time at 1000% of rating",
"symbol": "",
"kind": "electrical",
"unit": "sec",
"min": 0.01,
"typ": null,
"max": 0.15,
"conditions": "1000% of ampere rating, 1A-3.15A",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Maximum voltage drop at rated current",
"symbol": "",
"kind": "electrical",
"unit": "mV",
"min": null,
"typ": null,
"max": 350,
"conditions": "At rated current",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Maximum power dissipation",
"symbol": "",
"kind": "electrical",
"unit": "W",
"min": null,
"typ": null,
"max": 2.5,
"conditions": "At 1.5In",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Operating temperature",
"symbol": "",
"kind": "recommended_operating",
"unit": "°C",
"min": -55,
"typ": null,
"max": 125,
"conditions": "",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Voltage rating",
"symbol": "",
"kind": "recommended_operating",
"unit": "V",
"min": null,
"typ": null,
"max": 250,
"conditions": "",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Ampere rating",
"symbol": "",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": 1,
"max": null,
"conditions": "Amp code 001.",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Nominal cold resistance",
"symbol": "",
"kind": "electrical",
"unit": "Ohms",
"min": null,
"typ": 0.1515,
"max": null,
"conditions": "",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Nominal melting I2t",
"symbol": "",
"kind": "electrical",
"unit": "A2 sec",
"min": null,
"typ": 1.52,
"max": null,
"conditions": "I2t test at 10x rated current",
"source_page": 2,
"source": "datasheet"
}
]
}
},
"variants": [],
"sections": [
"hero",
"viewers",
"readme",
"breadcrumbs",
"info"
],
"discovery_triggers": [
"0215001.mxp"
],
"discovery_pitch": "0215001.MXP (Littelfuse) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
"author": {
"name": "Ray"
},
"dependencies": {},
"hero": {
"type": "image",
"path": "docs/hero.png"
},
"files": [
"page.json",
"README.md",
"0215001-mxp.kicad_sym",
"0215001-mxp.kicad_mod",
"0215001-mxp.glb",
"0215001-mxp.step",
"0215001-mxp.lbr",
"docs/hero.png",
"docs/0215001-mxp-datasheet.pdf",
"viewers/symbol.html",
"viewers/footprint.html",
"0215001-mxp-hero.glb",
"0215001-mxp-hero.overlay.json"
],
"visibility": "public",
"description": "Littelfuse Disposable Fuses, D5.2xL20mm. Pinout settled in review by an AI reviewer against the manufacturer's datasheet, KiCad symbol/footprint/3D.",
"org": "adom"
}