component
UTC2000T-I
Public Unreviewedby Ray
Microchip Tech Power Management - Specialized, QFN-16-EP(3x3). Datasheet-verified pinout, KiCad symbol/footprint/3D.
3D Model
Open in new tab ↗
Loads on click. Unloads when scrolled away or the tab is hidden.
Symbol & Footprint
Schematic Symbol
Open full view ↗Loads on click. Unloads when scrolled away or the tab is hidden.
PCB Footprint
Open full view ↗Loads on click. Unloads when scrolled away or the tab is hidden.
Datasheet
Open in new tab ↗Loads on click. Unloads when scrolled away or the tab is hidden.
README
markdownUTC2000T-I
Microchip Tech · Power Management - Specialized · QFN-16-EP(3x3)
UTC2000T-I from Microchip Tech, in a QFN-16-EP(3x3). Pinout and pin descriptions extracted from the manufacturer datasheet by ds2sf; symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | OCS# | input | Active-low fault input (Schmitt-triggered, internal ~100 µA pull-up). Asserted by the +5V VBUS power-supply device to notify the UTC2000 of a system fault (typically overcurrent/overvoltage). All digital control outputs revert to their default deasserted state while OCS# is asserted, and FAULT_IND latches high until reset/power cycle. |
| 2 | CFG_SEL | input | Analog configuration-select input sampled at power-on (at Vcfg_samp) to place the device in DFP or UFP mode and select the DFP charging profile (Legacy 500 mA / 900 mA, 1.5 A, or 3.0 A). Voltage thresholds are defined in Table 3-1 (DFP) and Table 3-2 (UFP). |
| 3 | ENABLE | input | Active-high controller enable (Schmitt-triggered digital input). When low, the UTC2000 remains in the Disabled Idle state with default deasserted outputs. If unused, tie to VDD through a 10 kΩ pull-up resistor. |
| 4 | FAULT_IND | output | Active-high fault indicator output (O25, 25 mA sink/source push-pull). Asserted after an OCS# overcurrent event or a VMON overvoltage event; cleared by toggling ENABLE (OCS# case) or by a power cycle (VMON case). |
| 5 | AUDIO_ADAPTER/CONNECTED# | output | Muxed function output. In DFP modes: active-high AUDIO_ADAPTER output (O25) indicating detection of a USB audio adapter (used to toggle a high-speed USB/audio switch). In UFP mode: open-drain active-low CONNECTED# output (OD25) that asserts when a valid USB Type-C connection is detected on the CC pin and VBUS is within range. |
| 6 | CC2 | input | USB Type-C CC2 monitor pin (ADC input). Samples the CC2 line voltage to detect connect/disconnect, Rd/Ra pull-downs, plug orientation, and charging capability. Detection thresholds are defined in Table 3-1 (DFP) and Table 3-2 (UFP). |
| 7 | CC1 | input | USB Type-C CC1 monitor pin (ADC input). Samples the CC1 line voltage to detect connect/disconnect, Rd/Ra pull-downs, plug orientation, and charging capability. Detection thresholds are defined in Table 3-1 (DFP) and Table 3-2 (UFP). |
| 8 | VCONN2_OUT#/LEGACY_IND# | output | Muxed open-drain output (OD25, 25 mA). In DFP modes: active-low VCONN2_OUT# controls the external switch supplying 5 V VCONN to CC2 for active-cable circuitry. In UFP mode: active-low LEGACY_IND# asserts when a valid USB Type-C connection is detected with legacy 500 mA / 900 mA charging capability. |
| 9 | VCONN1_OUT#/1.5A_IND# | output | Muxed open-drain output (OD25, 25 mA). In DFP modes: active-low VCONN1_OUT# controls the external switch supplying 5 V VCONN to CC1 for active-cable circuitry. In UFP mode: active-low 1.5A_IND# asserts when a valid USB Type-C connection is detected with 1.5 A charging capability. |
| 10 | PPC_EN/3.0A_IND# | output | Muxed output. In DFP modes: active-high PPC_EN (O25) enables the external 5 V VBUS port-power controller when a valid USB Type-C connection is detected. In UFP mode: active-low 3.0A_IND# (OD25) asserts when a valid USB Type-C connection is detected with 3.0 A charging capability. |
| 11 | PLUG_ORIENTATION# | output | Open-drain active-low plug-orientation indicator output (OD25, 25 mA). Remains high (unasserted) in the default unconnected state or when an Rd pull-down is detected on CC1. Asserts low when an Rd pull-down is detected on CC2, indicating a flipped plug - used to drive the external USB mux/switch. |
| 12 | VMON | input | VBUS voltage-monitor ADC input. Monitors the USB receptacle VBUS (via an external resistor divider). If VMON exceeds 0.8 V (corresponding to >6.4 V on VBUS), the device enters the fault state and deasserts all outputs. Required in UFP modes; in DFP modes, if unused, tie to GND through a 10 kΩ pull-down resistor. |
| 13 | VSS | power_in | Device ground. The exposed pad on the underside of the QFN package must also be connected to VSS/ground. |
| 14 | NC | unconnected | No connect. Leave unconnected (or tie per Microchip recommendation). |
| 15 | NC | unconnected | No connect. Leave unconnected (or tie per Microchip recommendation). |
| 16 | VDD | power_in | 5.0 V power input (operating range 4.5 V to 5.5 V). A minimum of one 0.1 µF bypass capacitor placed close to the pin is recommended. The high level of all digital outputs is referenced to VDD. |
| 17 | EP | power_in | Exposed thermal/ground pad on the underside of the QFN-16 package. Must be connected to VSS/ground for proper operation and thermal performance. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | Microchip Tech |
| Package | QFN-16-EP(3x3) |
| Category | Power Management (PMIC) |
| Pins | 17 |
Ordering variants
Same part, different packaging or reel option.
UTC2000T-II/MGUTC2000T-I/MG
CAD (KiCad official)
- Symbol:
UTC2000T-I - Footprint:
Package_DFN_QFN:QFN-16-1EP_3x3mm_P0.5mm_EP1.7x1.7mm - 3D model: QFN-16-EP(3x3) (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: Microchip Tech datasheet (42 pp, sha256
42a771aa3c2bd227, retrieved 2026-08-17, tier: lcsc) - Extractor:
ds2sf(Claude). Every pin and dimension is cited to a datasheet page; it refuses to fabricate. - CAD: KiCad official libraries (CC-BY-SA 4.0).