CFR-25JT-52-220K

YAGEO · Through Hole Resistors · R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal

CFR-25JT-52-220K from YAGEO, in a R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model); symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised resistor; either orientation.
2 2 passive Terminal 2 of an unpolarised resistor; either orientation.

Key specifications

Parameter Value
Manufacturer YAGEO
Package R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal
Category Resistors
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Resistance tolerance -5 5 % Tolerance code J = ±5% 2
Temperature coefficient of resistance TCR -700 0 ppm/°C CFR-25, resistance 100K ~ 1MΩ 4
Maximum working voltage 250 V CFR-25 column 3
Maximum overload voltage 500 V CFR-25 column 3
Voltage proof on insulation 500 V CFR-25 column 3
Resistance range (minimum) 1 Ω E24 series value 3
Resistance range (maximum) 10 MΩ E24 series value 3
Operating temperature range -55 155 °C Operating Temp. Range 3
Short time overload, resistance change ΔR -0.75 0.75 % IEC 60115-1 4.13, 2.5 times RCWV for 5 sec. 4
Short time overload, resistance change offset ΔR 0.05 Ω IEC 60115-1 4.13, 2.5 times RCWV for 5 sec. 4
Periodic-pulse overload, resistance change ΔR -1 1 % IEC 60115-1 4.39, 4 times RCWV (or Umax., whichever less), 10,000 cycles (1 Sec. on, 25 Sec. off) 4
Periodic-pulse overload, resistance change offset ΔR 0.05 Ω IEC 60115-1 4.39, 4 times RCWV (or Umax., whichever less), 10,000 cycles (1 Sec. on, 25 Sec. off) 4
Damp heat steady state, resistance change ΔR -3 3 % IEC 60115-1 4.24, 40±2°C, 90-95% RH for 56 days, loaded with 0.1 times RCWV (or Umax., whichever less) 4
Damp heat steady state, resistance change offset ΔR 0.05 Ω IEC 60115-1 4.24, 40±2°C, 90-95% RH for 56 days, loaded with 0.1 times RCWV (or Umax., whichever less) 4
Endurance at 70°C, resistance change ΔR -3 3 % IEC 60115-1 4.25, 70±2°C at RCWV (or Umax., whichever less) for 1,000 Hr. (1.5 Hr. on, 0.5 Hr. off) 4
Endurance at 70°C, resistance change offset ΔR 0.05 Ω IEC 60115-1 4.25, 70±2°C at RCWV (or Umax., whichever less) for 1,000 Hr. (1.5 Hr. on, 0.5 Hr. off) 4
Temperature cycling, resistance change ΔR -1 1 % IEC 60115-1 4.19, -55°C ➔ Room Temp. ➔ +155°C ➔ Room Temp. (5 cycles) 4
Temperature cycling, resistance change offset ΔR 0.05 Ω IEC 60115-1 4.19, -55°C ➔ Room Temp. ➔ +155°C ➔ Room Temp. (5 cycles) 4
Resistance to soldering heat, resistance change ΔR -1 1 % IEC 60115-1 4.18, 260±3°C for 10±1 Sec., immersed to a point 3±0.5mm from the body 4
Resistance to soldering heat, resistance change offset ΔR 0.05 Ω IEC 60115-1 4.18, 260±3°C for 10±1 Sec., immersed to a point 3±0.5mm from the body 4
Insulation resistance 1000 MΩ IEC 60115-1 4.6, In V-Block for 60 sec. 4
Solderability, minimum coverage 95 % IEC 60115-1 4.17, 245±5°C for 3±0.5 Sec. 4
Robustness of terminations, minimum direct load 2.5 Kg IEC 60115-1 4.16, direct load for 10 Sec. in the direction of the terminal leads 4

CAD (KiCad official)

  • Symbol: CFR-25JT-52-220K
  • Footprint: Resistor_THT:R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal
  • 3D model: R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: YAGEO datasheet (16 pp, sha256 76319a6451937e77, retrieved 2026-11-06, tier: lcsc)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).