3D Model
Open in new tab ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.
Symbol & Footprint
Schematic Symbol
Open full view ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
PCB Footprint
Open full view ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
Datasheet
Open in new tab ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
README
markdown0603L004
LUTE · Resettable Fuses · 0603
0603L004 from LUTE, in a 0603. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0603 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Hold current | I hold | 0.04 | A | 25°C still air; maximum current without tripping | 1 | ||
| Trip current | I trip | 0.12 | A | 25°C still air; minimum current at which device trips | 1 | ||
| Maximum fault current | I max | 20 | A | at rated voltage (V max) | 1 | ||
| Power dissipated when tripped | P d | 0.5 | W | tripped state, 25°C still air | 1 | ||
| Maximum time to trip | T trip | 1 | s | at 0.20 A | 1 | ||
| Minimum initial resistance | R min | 4 | Ω | initial, un-soldered state | 1 | ||
| Maximum resistance after trip or reflow | R 1max | 40 | Ω | 25°C, measured one hour after tripping or reflow soldering at 260°C for 20 s | 1 | ||
| Resistance change, passive aging | -5 | 5 | % | +85°C, 1000 hours; typical | 4 | ||
| Resistance change, humidity aging | -5 | 5 | % | +85°C, 85% R.H., 168 hours; typical | 4 | ||
| Resistance change, thermal shock | -33 | 33 | % | +85°C to -40°C, 20 times; typical | 4 | ||
| Ambient operating temperature | TA | -40 | 85 | °C | ambient operating conditions | 4 | |
| Maximum surface temperature in tripped state | 125 | °C | device in tripped state | 4 | |||
| Storage temperature | TSTORE | 0 | 30 | °C | storage condition, 30%-60% RH | 6 |
CAD (KiCad official)
- Symbol:
0603L004 - Footprint:
Fuse:Fuse_0603_1608Metric - 3D model: 0603 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256
9b801c861db9e4a6, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).