3D Model
Open in new tab ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.
Symbol & Footprint
Schematic Symbol
Open full view ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
PCB Footprint
Open full view ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
Datasheet
Open in new tab ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
README
markdown0603L012
LUTE · Resettable Fuses · 0603
0603L012 from LUTE, in a 0603. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0603 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Hold current | I hold | 0.12 | A | 25℃ still air; maximum current device passes without tripping (same for all 0603L012 voltage variants) | 2 | ||
| Trip current | I trip | 0.36 | A | 25℃ still air; minimum current at which device trips | 2 | ||
| Time to trip (max) | 0.2 | s | at 0.80 A trip-test current | 2 | |||
| Minimum initial resistance | R min | 0.7 | Ω | initial un-soldered state | 2 | ||
| Maximum resistance after trip or reflow | R1max | 6 | Ω | 25℃, measured one hour after tripping or reflow soldering at 260℃ for 20 s | 2 | ||
| Power dissipated in tripped state | Pd | 0.7 | W | typical, tripped state, 25℃ still air | 2 | ||
| Passive aging resistance change | -5 | 5 | % | +85℃, 1000 hours; typical | 5 | ||
| Humidity aging resistance change | -5 | 5 | % | +85℃, 85% R.H., 168 hours; typical | 5 | ||
| Thermal shock resistance change | -33 | 33 | % | +85℃ to -40℃, 20 times; typical | 5 | ||
| Ambient operating temperature | TA | -40 | 85 | °C | ambient operating conditions | 5 | |
| Maximum surface temperature in tripped state | 125 | °C | device in tripped state | 5 | |||
| Storage temperature | TSTORE | 0 | 30 | °C | storage condition, 30%-60% RH | 7 | |
| Hold current derating at -40℃ | I hold | 0.19 | A | ambient operating temperature -40℃ (0603L012) | 6 | ||
| Hold current derating at -20℃ | I hold | 0.17 | A | ambient operating temperature -20℃ (0603L012) | 6 | ||
| Hold current derating at 0℃ | I hold | 0.15 | A | ambient operating temperature 0℃ (0603L012) | 6 | ||
| Hold current derating at 25℃ | I hold | 0.12 | A | ambient operating temperature 25℃ (0603L012) | 6 | ||
| Hold current derating at 40℃ | I hold | 0.1 | A | ambient operating temperature 40℃ (0603L012) | 6 | ||
| Hold current derating at 50℃ | I hold | 0.09 | A | ambient operating temperature 50℃ (0603L012) | 6 | ||
| Hold current derating at 60℃ | I hold | 0.08 | A | ambient operating temperature 60℃ (0603L012) | 6 | ||
| Hold current derating at 70℃ | I hold | 0.06 | A | ambient operating temperature 70℃ (0603L012) | 6 | ||
| Hold current derating at 85℃ | I hold | 0.05 | A | ambient operating temperature 85℃ (0603L012) | 6 |
CAD (KiCad official)
- Symbol:
0603L012 - Footprint:
Fuse:Fuse_0603_1608Metric - 3D model: 0603 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (10 pp, sha256
cbbadcaddb0d0e0b, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).