Loads when you scroll to it. Unloads after 5 minutes in the background.

Symbol & Footprint

Schematic Symbol

Open full view ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.

PCB Footprint

Open full view ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.
Loads when you scroll to it. Unloads after 5 minutes in the background.
Download PDF
Contents

README

markdown

0805L050

LUTE · Resettable Fuses · 0805

0805L050 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0805
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Hold current (I hold) I hold 0.5 A 25°C still air; maximum current without tripping; all 0805L050/xXR codes 2
Trip current (I trip) I trip 1 A 25°C still air; minimum current at which device trips; all 0805L050/xXR codes 2
Maximum fault current (I max) I max 40 A at rated voltage (V max); all 0805L050/xXR codes 2
Maximum voltage, 0805L050/6XR V max 6 Vdc 0805L050/6XR; at rated current (I max) 2
Maximum voltage, 0805L050/12XR V max 12 Vdc 0805L050/12XR; at rated current (I max) 2
Maximum voltage, 0805L050/15XR V max 15 Vdc 0805L050/15XR; at rated current (I max) 2
Maximum voltage, 0805L050/24XR V max 24 Vdc 0805L050/24XR; at rated current (I max) 2
Initial minimum resistance (R min) R min 0.1 Ω initial (un-soldered) state; all 0805L050/xXR codes 2
Maximum resistance after trip or reflow (R 1max) R 1max 0.85 Ω 25°C, measured one hour after tripping or 260°C reflow for 20 s; all 0805L050/xXR codes 2
Maximum time to trip T trip 0.1 s at assigned current 8.00 A; Time to Trip (Max.) 2
Power dissipated when tripped, 0805L050/6XR, /12XR, /15XR P d 0.5 W typical, tripped state, 25°C still air 2
Power dissipated when tripped, 0805L050/24XR P d 0.8 W typical, tripped state, 25°C still air; 0805L050/24XR only 2
Hold current derating at -40°C I hold 0.68 A ambient operating temperature -40°C; 0805L050 5
Hold current derating at -20°C I hold 0.62 A ambient operating temperature -20°C; 0805L050 5
Hold current derating at 0°C I hold 0.55 A ambient operating temperature 0°C; 0805L050 5
Hold current derating at 25°C I hold 0.5 A ambient operating temperature 25°C; 0805L050 5
Hold current derating at 40°C I hold 0.4 A ambient operating temperature 40°C; 0805L050 5
Hold current derating at 50°C I hold 0.37 A ambient operating temperature 50°C; 0805L050 5
Hold current derating at 60°C I hold 0.33 A ambient operating temperature 60°C; 0805L050 5
Hold current derating at 70°C I hold 0.29 A ambient operating temperature 70°C; 0805L050 5
Hold current derating at 85°C I hold 0.23 A ambient operating temperature 85°C; 0805L050 5
Resistance change after passive aging -5 5 % +85°C, 1000 hours; typical 4
Resistance change after humidity aging -5 5 % +85°C, 85% R.H., 168 hours; typical 4
Resistance change after thermal shock -33 33 % +85°C to -40°C, 20 times; typical 4
Ambient operating temperature -40 85 °C ambient operating conditions 4
Maximum surface temperature in tripped state 125 °C device in tripped state 4
Storage temperature 0 30 °C storage condition; 30%-60% RH 6

CAD (KiCad official)

  • Symbol: 0805L050
  • Footprint: Fuse:Fuse_0805_2012Metric
  • 3D model: 0805 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256 02a164fafb86ec79, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF