Loads when you scroll to it. Unloads after 5 minutes in the background.

Symbol & Footprint

Schematic Symbol

Open full view ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.

PCB Footprint

Open full view ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.
Loads when you scroll to it. Unloads after 5 minutes in the background.
Download PDF
Contents

README

markdown

0805L050

LUTE · Resettable Fuses · 0805

0805L050 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0805
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Hold current (I hold) I hold 0.5 A 25℃ still air; identical in all 0805L050/xxR rows 3
Trip current (I trip) I trip 1 A 25℃ still air; identical in all 0805L050/xxR rows 3
Maximum fault current (I max) I max 40 A at rated voltage V max; identical in all 0805L050/xxR rows 3
Time to trip (max) at 8.00 A T trip 0.1 s at 8.00 A current, 25℃ still air 3
Minimum initial resistance (R min) R min 0.1 Ω initial un-soldered state 3
Maximum resistance after trip or reflow (R 1max) R 1max 0.85 Ω 25℃, measured one hour after tripping or 260℃ reflow for 20 s 3
Hold current vs ambient temperature, -40℃ I hold 0.68 A ambient -40℃, 0805L050 row of thermal derating table 7
Hold current vs ambient temperature, -20℃ I hold 0.62 A ambient -20℃, 0805L050 row of thermal derating table 7
Hold current vs ambient temperature, 0℃ I hold 0.55 A ambient 0℃, 0805L050 row of thermal derating table 7
Hold current vs ambient temperature, 25℃ I hold 0.5 A ambient 25℃, 0805L050 row of thermal derating table 7
Hold current vs ambient temperature, 40℃ I hold 0.4 A ambient 40℃, 0805L050 row of thermal derating table 7
Hold current vs ambient temperature, 50℃ I hold 0.37 A ambient 50℃, 0805L050 row of thermal derating table 7
Hold current vs ambient temperature, 60℃ I hold 0.33 A ambient 60℃, 0805L050 row of thermal derating table 7
Hold current vs ambient temperature, 70℃ I hold 0.29 A ambient 70℃, 0805L050 row of thermal derating table 7
Hold current vs ambient temperature, 85℃ I hold 0.23 A ambient 85℃, 0805L050 row of thermal derating table 7
Ambient operating temperature TA -40 85 ℃ ambient operating conditions 6
Maximum surface temperature in tripped state 125 ℃ device in tripped state 6
Storage temperature TSTORE 0 30 ℃ storage condition, 30%-60% RH 8
Peak reflow temperature (Tp) 260 ℃ Pb-free reflow peak temperature 8
Time within 5℃ of peak reflow temperature (tp) 20 40 s within 5℃ of actual peak temperature in reflow 8
Resistance change, passive aging -5 5 % +85℃, 1000 hours; printed as ±5% typical 6
Resistance change, humidity aging -5 5 % +85℃, 85% R.H., 168 hours; printed as ±5% typical 6
Resistance change, thermal shock -33 33 % +85℃ to -40℃, 20 times; printed as ±33% typical 6

CAD (KiCad official)

  • Symbol: 0805L050
  • Footprint: Fuse:Fuse_0805_2012Metric
  • 3D model: 0805 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (11 pp, sha256 f3e6ec9863d8e836, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF