component
SN74CBT16214CDLR
Public Made by Adomby adom
Texas Instruments Signal Switches / Encoders & Decoders / Multiplexers, SSOP-56-300mil. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.
3D Model
Open in new tab ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.
Symbol & Footprint
Schematic Symbol
Open full view ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
PCB Footprint
Open full view ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
Datasheet
Open in new tab ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
README
markdownSN74CBT16214CDLR
Texas Instruments · Signal Switches / Encoders & Decoders / Multiplexers · SSOP-56-300mil
SN74CBT16214CDLR from Texas Instruments, in a SSOP-56-300mil. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model); symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | S0 | input | Select input that sets the 1-of-3 switch path; TTL-compatible with VIH minimum 2 V, VIL maximum 0.8 V, and a 5.5 V maximum, and should be tied to GND through a pulldown resistor to keep the switch in high-impedance during power up or power down. |
| 2 | 1A | bidirectional | Switch port A of multiplexer channel 1, connected to the selected B port when enabled, high-impedance when disconnected, with undershoot protection to −2 V. |
| 3 | 1B3 | bidirectional | Switch port B3 of channel 1, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 4 | 2A | bidirectional | Switch port A of multiplexer channel 2, connected to the selected B port when enabled, high-impedance when disconnected, with undershoot protection to −2 V. |
| 5 | 2B3 | bidirectional | Switch port B3 of channel 2, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 6 | 3A | bidirectional | Switch port A of multiplexer channel 3, connected to the selected B port when enabled, high-impedance when disconnected, with undershoot protection to −2 V. |
| 7 | 3B3 | bidirectional | Switch port B3 of channel 3, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 8 | GND | power_in | Device ground reference; all voltages are referenced to ground. |
| 9 | 4A | bidirectional | Switch port A of multiplexer channel 4, connected to the selected B port when enabled, high-impedance when disconnected, with undershoot protection to −2 V. |
| 10 | 4B3 | bidirectional | Switch port B3 of channel 4, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 11 | 5A | bidirectional | Switch port A of multiplexer channel 5, connected to the selected B port when enabled, high-impedance when disconnected, with undershoot protection to −2 V. |
| 12 | 5B3 | bidirectional | Switch port B3 of channel 5, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 13 | 6A | bidirectional | Switch port A of multiplexer channel 6, connected to the selected B port when enabled, high-impedance when disconnected, with undershoot protection to −2 V. |
| 14 | 6B3 | bidirectional | Switch port B3 of channel 6, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 15 | 7A | bidirectional | Switch port A of multiplexer channel 7, connected to the selected B port when enabled, high-impedance when disconnected, with undershoot protection to −2 V. |
| 16 | 7B3 | bidirectional | Switch port B3 of channel 7, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 17 | VCC | power_in | Supply voltage; recommended operating range is 4 V to 5.5 V. |
| 18 | 8A | bidirectional | Switch port A of multiplexer channel 8, connected to the selected B port when enabled, high-impedance when disconnected, with undershoot protection to −2 V. |
| 19 | GND | power_in | Device ground reference; all voltages are referenced to ground. |
| 20 | 8B3 | bidirectional | Switch port B3 of channel 8, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 21 | 9A | bidirectional | Switch port A of multiplexer channel 9, connected to the selected B port when enabled, high-impedance when disconnected, with undershoot protection to −2 V. |
| 22 | 9B3 | bidirectional | Switch port B3 of channel 9, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 23 | 10A | bidirectional | Switch port A of multiplexer channel 10, connected to the selected B port when enabled, high-impedance when disconnected, with undershoot protection to −2 V. |
| 24 | 10B3 | bidirectional | Switch port B3 of channel 10, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 25 | 11A | bidirectional | Switch port A of multiplexer channel 11, connected to the selected B port when enabled, high-impedance when disconnected, with undershoot protection to −2 V. |
| 26 | 11B3 | bidirectional | Switch port B3 of channel 11, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 27 | 12A | bidirectional | Switch port A of multiplexer channel 12, connected to the selected B port when enabled, high-impedance when disconnected, with undershoot protection to −2 V. |
| 28 | 12B3 | bidirectional | Switch port B3 of channel 12, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 29 | 12B2 | bidirectional | Switch port B2 of channel 12, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 30 | 12B1 | bidirectional | Switch port B1 of channel 12, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 31 | 11B2 | bidirectional | Switch port B2 of channel 11, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 32 | 11B1 | bidirectional | Switch port B1 of channel 11, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 33 | 10B2 | bidirectional | Switch port B2 of channel 10, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 34 | 10B1 | bidirectional | Switch port B1 of channel 10, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 35 | 9B2 | bidirectional | Switch port B2 of channel 9, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 36 | 9B1 | bidirectional | Switch port B1 of channel 9, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 37 | 8B2 | bidirectional | Switch port B2 of channel 8, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 38 | GND | power_in | Device ground reference; all voltages are referenced to ground. |
| 39 | 8B1 | bidirectional | Switch port B1 of channel 8, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 40 | 7B2 | bidirectional | Switch port B2 of channel 7, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 41 | 7B1 | bidirectional | Switch port B1 of channel 7, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 42 | 6B2 | bidirectional | Switch port B2 of channel 6, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 43 | 6B1 | bidirectional | Switch port B1 of channel 6, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 44 | 5B2 | bidirectional | Switch port B2 of channel 5, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 45 | 5B1 | bidirectional | Switch port B1 of channel 5, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 46 | 4B2 | bidirectional | Switch port B2 of channel 4, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 47 | 4B1 | bidirectional | Switch port B1 of channel 4, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 48 | 3B2 | bidirectional | Switch port B2 of channel 3, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 49 | GND | power_in | Device ground reference; all voltages are referenced to ground. |
| 50 | 3B1 | bidirectional | Switch port B1 of channel 3, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 51 | 2B2 | bidirectional | Switch port B2 of channel 2, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 52 | 2B1 | bidirectional | Switch port B1 of channel 2, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 53 | 1B2 | bidirectional | Switch port B2 of channel 1, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 54 | 1B1 | bidirectional | Switch port B1 of channel 1, connected to A when selected by S0-S2 and high-impedance when disconnected, with undershoot protection to −2 V. |
| 55 | S2 | input | Select input that sets the 1-of-3 switch path; TTL-compatible with VIH minimum 2 V, VIL maximum 0.8 V, and a 5.5 V maximum, and should be tied to GND through a pulldown resistor to keep the switch in high-impedance during power up or power down. |
| 56 | S1 | input | Select input that sets the 1-of-3 switch path; TTL-compatible with VIH minimum 2 V, VIL maximum 0.8 V, and a 5.5 V maximum, and should be tied to GND through a pulldown resistor to keep the switch in high-impedance during power up or power down. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | Texas Instruments |
| Package | SSOP-56-300mil |
| Category | Logic ICs |
| Pins | 56 |
CAD (KiCad official)
- Symbol:
SN74CBT16214CDLR - Footprint:
Package_SO:SSOP-56_7.5x18.5mm_P0.635mm - 3D model: SSOP-56-300mil (KiCad packages3D, STEP)
- 3D model files:
sn74cbt16214cdlr-etched.step/sn74cbt16214cdlr-etched.glbcarry the MPN laser-etched on the die in a toggleableAdom.LaserEtchgroup (Fusion-ready);sn74cbt16214cdlr.step/sn74cbt16214cdlr.glbare the bare package body.
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: Texas Instruments datasheet (17 pp, sha256
6c74cd73ff65d596, retrieved 2026-10-11, tier: lcsc) - Extractor: parts-factory
2.0.0/extract_pins 0.3, primaryclaude-haiku-5-5(text), consensusclaude-sonnet-5-5(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).