by John Lauer
Two-board Molecule interferometer with onboard RP2040, USB-C data, 15 V USB-C PD power and a JST stage interface.
← Commit history
Link the comparison directly and fix evidence source links
2 files changed
+8−8
docs/comparison/README.md+6−6@@ -84,13 +84,13 @@ Each KiCad panel shows the symbol on the left and the footprint on the right. AI  -The four full-command ngspice cases settle near 135.392 mA. The worst simulated startup or shutdown peak is 135.394 mA, about 0.003 mA above its settled current. The results use vendor models for the pass MOSFET, supervisor, error amplifier and Schottky, plus an electrical fit for the laser diode. [Simulation results](../../sim/laser-results.json)+The four full-command ngspice cases settle near 135.392 mA. The worst simulated startup or shutdown peak is 135.394 mA, about 0.003 mA above its settled current. The results use vendor models for the pass MOSFET, supervisor, error amplifier and Schottky, plus an electrical fit for the laser diode. [Simulation results](https://wiki.adom.inc/john/self-mixing-interferometer/files/sim/laser-results.json) ### Photodiode amplifier stability  -This chart plots the reported OPA320 results at four gains. The two monitor polarities give the same phase margin and bandwidth at each gain. Phase margin ranges from 72.6° to 84.0°. Bandwidth ranges from 142 kHz at 150 kΩ to 4.32 MHz at 1 kΩ. The isolated nominal model includes input capacitance and leaves detector shot noise and most board parasitics outside its scope. [TIA simulation data](../../sim/tia-results.json)+This chart plots the reported OPA320 results at four gains. The two monitor polarities give the same phase margin and bandwidth at each gain. Phase margin ranges from 72.6° to 84.0°. Bandwidth ranges from 142 kHz at 150 kΩ to 4.32 MHz at 1 kΩ. The isolated nominal model includes input capacitance and leaves detector shot noise and most board parasitics outside its scope. [TIA simulation data](https://wiki.adom.inc/john/self-mixing-interferometer/files/sim/tia-results.json) ### Current and temperature across the copper @@ -98,13 +98,13 @@ This chart plots the reported OPA320 results at four gains. The two monitor pola  -The released Fields maps show where current concentrates and estimate a peak rise of 55.6 °C in still air for the specified load. The design review records open decoupling findings and an electrolytic temperature estimate near its rating. First-assembly measurements are still due. [Design review](../../design-review/README.md)+The released Fields maps show where current concentrates and estimate a peak rise of 55.6 °C in still air for the specified load. The design review records open decoupling findings and an electrolytic temperature estimate near its rating. First-assembly measurements are still due. [Design review](https://wiki.adom.inc/john/self-mixing-interferometer/files/design-review/README.md) ### Probe access  -The map plots the 13 front-side pad centers from the KiCad board and takes the net names from the project's probe plan. It identifies the power rails, shunt sense, TIA outputs, ADC inputs and sync pad. [Probe plan](../../docs/explorer/probe-map.json)+The map plots the 13 front-side pad centers from the KiCad board and takes the net names from the project's probe plan. It identifies the power rails, shunt sense, TIA outputs, ADC inputs and sync pad. [Probe plan](https://wiki.adom.inc/john/self-mixing-interferometer/files/docs/explorer/probe-map.json) ### Fabrication read-back @@ -113,7 +113,7 @@ The map plots the 13 front-side pad centers from the KiCad board and takes the n | 9 Gerbers and 2 drill files | Read the archive, checked file headers and terminators, and matched each file byte-for-byte against the JLCPCB upload ZIP. | | 49 assembly BOM rows and 134 placements | Matched the BOM and placement reference sets. Each placement's center and side match its footprint in the released KiCad board. | -These checks cover the released digital files. Assembly orientation and the supplier's production preview remain first-order checks. [Fabrication archive](../../self-mixing-interferometer-fab.zip) · [Fabrication notes](../../docs/fabrication.md)+These checks cover the released digital files. Assembly orientation and the supplier's production preview remain first-order checks. [Fabrication archive](https://wiki.adom.inc/john/self-mixing-interferometer/files/self-mixing-interferometer-fab.zip) · [Fabrication notes](https://wiki.adom.inc/john/self-mixing-interferometer/files/docs/fabrication.md) ## What the checks caught @@ -143,4 +143,4 @@ The board made without AI Flow has not had the same outside review, so it may ca Without AI Flow, the AI got to a clean DRC and a good write-up six times faster and with about a thirteenth of the processed tokens and a third of the generated tokens. With AI Flow, it produced a board whose laser driver, amplifiers and copper heat were simulated before ordering, and those checks found real faults. The two runs used different AIs and the AI Flow run had a supervisor, so this is a field report, not a controlled benchmark. A cleaner test would give the same AI the same prompt with and without AI Flow. -[Back to the board](../../README.md)+[Back to the board](https://wiki.adom.inc/john/self-mixing-interferometer)
readme.html+2−2@@ -115,8 +115,8 @@ aiflow-explorer { display: block; margin: 6px 0 24px; } <h2>Compare: with and without AI Flow</h2> <table> <tr>-<td width="104"><a href="https://wiki.adom.inc/john/self-mixing-interferometer/files/docs/comparison" target="_blank" rel="noopener"><img src="https://wiki.adom.inc/john/self-mixing-interferometer/render/docs/comparison/comparison-icon.png?v=66b37def" width="112" alt="The two interferometer boards"></a><br><sub> Board comparison </sub></td>-<td>See what two AI runs built from the same interferometer brief. The side-by-side board views and schematics show how the designs diverged. Inspect the 3D models and the evidence behind the design checks.<br><br><a href="https://wiki.adom.inc/john/self-mixing-interferometer/files/docs/comparison" target="_blank" rel="noopener">Compare the boards</a></td>+<td width="104"><a href="https://wiki.adom.inc/john/self-mixing-interferometer/files/docs/comparison/README.md" target="_blank" rel="noopener"><img src="https://wiki.adom.inc/john/self-mixing-interferometer/render/docs/comparison/comparison-icon.png?v=66b37def" width="112" alt="The two interferometer boards"></a><br><sub> Board comparison </sub></td>+<td>See what two AI runs built from the same interferometer brief. The side-by-side board views and schematics show how the designs diverged. Inspect the 3D models and the evidence behind the design checks.<br><br><a href="https://wiki.adom.inc/john/self-mixing-interferometer/files/docs/comparison/README.md" target="_blank" rel="noopener">Compare the boards</a></td> </tr> </table> </section>