by John Lauer
Wi-Fi HaLow gate controller with isolated opener commands, position sensing, and a solar-battery input.
main
John Lauer
Publish 1.0.0
768468c
Prototype bench plan
- Connect a current-limited bench supply at MC1 and MC2. Check the protected rail at 9, 12, 24, and 30 V. Compare the battery telemetry with the input meter. Exercise reverse input and brownout on the bench.
- Use dummy opener inputs to test the default 500 ms open pulse, configuration of the spare output, simultaneous commands, startup, radio loss during a pulse, and reset. Verify both contacts open when control power is removed.
- Use dry switches and known cable lengths to check both wetted position inputs. Check open and closed transitions, contact bounce, and disconnected wire behavior.
- Drive the isolated fault input from a documented, compatible status source on the bench. Record assertion and recovery levels. Verify the controller reports active status and inhibits pulses while the fault remains active.
- Measure 3.3 V near the radio under transmit loading. Check temperature at the regulator and rail links at the maximum intended enclosure ambient.
- Use a conducted setup to characterize the RF feed and antenna match, and verify the selected antenna and module configuration against the manufacturer's integration guidance.
- Before installing, confirm the actual opener's command behavior and signal ratings. Verify its independent safety devices, including when the controller is unpowered or disconnected.
# Prototype bench plan
1. Connect a current-limited bench supply at MC1 and MC2. Check the protected rail at 9, 12, 24, and 30 V. Compare the battery telemetry with the input meter. Exercise reverse input and brownout on the bench.
2. Use dummy opener inputs to test the default 500 ms open pulse, configuration of the spare output, simultaneous commands, startup, radio loss during a pulse, and reset. Verify both contacts open when control power is removed.
3. Use dry switches and known cable lengths to check both wetted position inputs. Check open and closed transitions, contact bounce, and disconnected wire behavior.
4. Drive the isolated fault input from a documented, compatible status source on the bench. Record assertion and recovery levels. Verify the controller reports active status and inhibits pulses while the fault remains active.
5. Measure 3.3 V near the radio under transmit loading. Check temperature at the regulator and rail links at the maximum intended enclosure ambient.
6. Use a conducted setup to characterize the RF feed and antenna match, and verify the selected antenna and module configuration against the manufacturer's integration guidance.
7. Before installing, confirm the actual opener's command behavior and signal ratings. Verify its independent safety devices, including when the controller is unpowered or disconnected.