main
Name Last commit message Last updated
current-density.png Publish 1.0.0 · John Lauer
heat-flow.png Publish 1.0.0 · John Lauer
README.md Record the coil eFuse thermal screening result · John Lauer
temperature-rise.png Publish 1.0.0 · John Lauer

P7 electrical and thermal review

KiCad 10.0.8 checked the four-layer release board with all five zones filled. It reported zero unconnected items, DRC findings, schematic parity findings and schematic ERC findings. The release archive contains both inner and both outer copper layers.

Current density

Adom Fields screened the saved board at 0.20 mm resolution. The fixed +24 V terminal model applies 1.25 A in total and assigns 0.17 mA to the voltage-divider branch.

Net Modeled load (A) Peak (A/mm²)
/+24V 1.250 53.49
/GND 1.250 13.59
/+3V3 0.350 46.14
/COIL_P 0.432 55.54
/FAN_P 0.432 36.84
/LED_SW 0.832 60.03
/SENS_24V 0.288 59.92

The short LED switch-node bottleneck reaches 60.03 A/mm² against the 60 A/mm² screening threshold. The result warrants measurement on the prototype under full LED load. Total modeled copper loss is 0.086 W.

Current density plot

Temperature rise

The board-only screen applies 2.60 W across the PoE module's modeled leads. It reports a rise of 81.4 °C at its reference lead in still air and 62.3 °C in moving air. The still-air mesh maximum is +228.1 °C at PS1 pin 4, an intentionally unconnected internal-connection pin. The model deposits heat in that pad and omits convection from the module body, so the local peak is unsuitable as a prediction of module temperature.

At the design load of 21.48 W, the Silvertel curves indicate approximately 1.9 W to 2.5 W of converter dissipation. Silvertel measured its hottest component, Q3, at 64.7 °C with 30 °C chamber ambient, 56.26 V input and 29.7 W output. The dock layout follows the manufacturer's recommendation to spread heat from both output rails into outer copper pours using plated vias. The dock enclosure's full-load testing is pending. Silvertel thermal characterization

The coil eFuse U11 also exceeds AI Flow's automatic 5.58 °C screening allowance. Its modeled rise is 32.2 °C in still air and 15.2 °C in moving air. Thermal validation of the coil and PoE stages under dock load is pending.

Heat flow · Temperature rise