main
John Lauer TP5: GND probe pad beside TP3 for the probing workcell; probing guide with the TP5 loop video and scope plots; molecule… 61f1679
{
 "asset": "3d/L_Abracon_AMPLH5030S.step",
 "part": {
  "manufacturer": "Abracon",
  "mpn": "AMPLH5030S-150MT",
  "series": "AMPLH5030S"
 },
 "classification": "AI-created",
 "source": {
  "url": "https://abracon.com/datasheets/AMPLH5030S.pdf",
  "revision": "Initial Release 2/27/2024",
  "page": 3,
  "figure": "Mechanical Specifications (top/front/bottom views) and Recommended Land Pattern",
  "retrieved": "2026-09-29",
  "sha256": "9ea47350f1f287dfa808ca5700dc0df65391eb55fbb616694f76aeb71a4ea861"
 },
 "dimensions_mm": {
  "body": [
   5.6,
   5.2,
   2.8
  ],
  "electrode_bottom": [
   1.3,
   3.0
  ],
  "tolerances": "body X +/-0.30, Y +/-0.20, Z +/-0.20; electrode +/-0.30"
 },
 "simplifications": [
  "square body edges (no draft/radius)",
  "electrodes as 0.05 mm underside slabs + 0.6 mm end-face wrap",
  "no ink marking"
 ],
 "generator": {
  "script": "tools/make_amplh5030s_step.py",
  "sha256": "8be95051cdd004ee62cb9c2eb7c4a71b686deb2b02c3f97ca7d86a2820e2333e",
  "kernel": "OpenCascade via cadquery-ocp 8.0.1 (local install; made before John's rule to use the shared step2glb OCCT service; the service's create-chip is chipsmith-based, which John ruled out)"
 },
 "output_sha256": {
  "step": "b143fd390c2aca7d1bff5943f4f4b163d828645709de6cc90c0445f1a6079a8e",
  "glb": "dc8ddaa6350a498674c2eddcedea86e52057b0fc536f15b2f8b9d207fa2c6221"
 },
 "checks": {
  "step2glb_features": "bbox 5.66 x 5.20 x 2.80 mm, floor z=0, long axis x (pad axis), pin1 unknown (non-polar part)",
  "step2glb_convert": "5 meshes, 2 materials (body 0.18 grey, electrodes 0.80 tin)",
  "render": "3d/L_Abracon_AMPLH5030S-iso.png inspected",
  "native_kicad_3d": "pending (models step)"
 },
 "redistribution": "independently generated from published datasheet dimensions; no manufacturer CAD used"
}