main
John Lauer ECAS vs MLCC: a study of moving the buck to polymer capacitors, with its section card 531f515
[
 {
  "cout_scale": 1.0,
  "why": "measured, 25 C",
  "cff": 47,
  "vin": 9,
  "fc_kHz": 30.4,
  "pm": 104.0
 },
 {
  "cout_scale": 1.0,
  "why": "measured, 25 C",
  "cff": 47,
  "vin": 16,
  "fc_kHz": 30.1,
  "pm": 101.1
 },
 {
  "cout_scale": 1.0,
  "why": "measured, 25 C",
  "cff": 68,
  "vin": 9,
  "fc_kHz": 40.9,
  "pm": 114.4
 },
 {
  "cout_scale": 1.0,
  "why": "measured, 25 C",
  "cff": 68,
  "vin": 16,
  "fc_kHz": 40.0,
  "pm": 110.8
 },
 {
  "cout_scale": 0.8,
  "why": "-20 % tolerance",
  "cff": 47,
  "vin": 9,
  "fc_kHz": 43.4,
  "pm": 107.1
 },
 {
  "cout_scale": 0.8,
  "why": "-20 % tolerance",
  "cff": 47,
  "vin": 16,
  "fc_kHz": 42.6,
  "pm": 103.3
 },
 {
  "cout_scale": 0.8,
  "why": "-20 % tolerance",
  "cff": 68,
  "vin": 9,
  "fc_kHz": 96.0,
  "pm": 99.7
 },
 {
  "cout_scale": 0.8,
  "why": "-20 % tolerance",
  "cff": 68,
  "vin": 16,
  "fc_kHz": 78.5,
  "pm": 100.3
 },
 {
  "cout_scale": 0.68,
  "why": "-20 % tolerance and X5R at 85 C (-15 %)",
  "cff": 47,
  "vin": 9,
  "fc_kHz": 62.0,
  "pm": 106.9
 },
 {
  "cout_scale": 0.68,
  "why": "-20 % tolerance and X5R at 85 C (-15 %)",
  "cff": 47,
  "vin": 16,
  "fc_kHz": 58.8,
  "pm": 102.3
 },
 {
  "cout_scale": 0.68,
  "why": "-20 % tolerance and X5R at 85 C (-15 %)",
  "cff": 68,
  "vin": 9,
  "fc_kHz": 205.7,
  "pm": 30.0
 },
 {
  "cout_scale": 0.68,
  "why": "-20 % tolerance and X5R at 85 C (-15 %)",
  "cff": 68,
  "vin": 16,
  "fc_kHz": 127.9,
  "pm": 73.3
 },
 {
  "part": "ecas150",
  "cout_scale": 1.0,
  "cff": 220,
  "vin": 16,
  "fc_kHz": 6.4,
  "pm": 100.8
 },
 {
  "part": "ecas150",
  "cout_scale": 0.8,
  "cff": 220,
  "vin": 16,
  "fc_kHz": 8.7,
  "pm": 110.6
 }
]