← Commit history

Set visibility: public

Ray ·57bc0ddb2f · ·parent f0bd115
1 file changed +24−21
page.json+24−21
@@ -38,67 +38,67 @@         "number": "1",         "name": "M2",         "type": "input",-        "description": "Mode Input pin; selects output mode configuration; internally pulled low with 1\u03bcA"+        "description": "Mode Input pin; selects output mode configuration; internally pulled low with 1μA"       },       {         "number": "2",         "name": "M1",         "type": "input",-        "description": "Mode Input pin; selects voltage or current output mode; internally pulled low with 1\u03bcA"+        "description": "Mode Input pin; selects voltage or current output mode; internally pulled low with 1μA"       },       {         "number": "3",         "name": "VIN",         "type": "power_in",-        "description": "Noninverting Signal Input for operational amplifier; voltage range (V\u2212)+3V to (V+)\u22123V"+        "description": "Noninverting Signal Input for operational amplifier; voltage range (V−)+3V to (V+)−3V"       },       {         "number": "4",         "name": "SET",         "type": "input",-        "description": "Input for Gain Setting and Inverting Input for operational amplifier; voltage range (V\u2212)+3V to (V+)\u22123V"+        "description": "Input for Gain Setting and Inverting Input for operational amplifier; voltage range (V−)+3V to (V+)−3V"       },       {         "number": "5",         "name": "IMON",         "type": "output",-        "description": "Current Monitor Output; provides 1/10 copy of output current; output swing (V\u2212)+3V to (V+)\u22123V"+        "description": "Current Monitor Output; provides 1/10 copy of output current; output swing (V−)+3V to (V+)−3V"       },       {         "number": "6",         "name": "IAOUT",         "type": "output",-        "description": "Instrumentation Amplifier Signal Output current; output swing (V\u2212)+3V to (V+)\u22123V"+        "description": "Instrumentation Amplifier Signal Output current; output swing (V−)+3V to (V+)−3V"       },       {         "number": "7",-        "name": "IAIN\u2212",+        "name": "IAIN−",         "type": "input",-        "description": "Instrumentation Amplifier Inverting Input; voltage range (V\u2212)+3V to (V+)\u22123V"+        "description": "Instrumentation Amplifier Inverting Input; voltage range (V−)+3V to (V+)−3V"       },       {         "number": "8",         "name": "IAIN+",         "type": "input",-        "description": "Instrumentation Amplifier Noninverting Input; voltage range (V\u2212)+3V to (V+)\u22123V"+        "description": "Instrumentation Amplifier Noninverting Input; voltage range (V−)+3V to (V+)−3V"       },       {         "number": "9",         "name": "RG1",         "type": "passive",-        "description": "Instrumentation Amplifier Gain Resistor connection point; external resistor determines IA gain per IAOUT=2(IAIN+\u2212IAIN\u2212)/RGAIN"+        "description": "Instrumentation Amplifier Gain Resistor connection point; external resistor determines IA gain per IAOUT=2(IAIN+−IAIN−)/RGAIN"       },       {         "number": "10",         "name": "RG2",         "type": "passive",-        "description": "Instrumentation Amplifier Gain Resistor connection point; external resistor determines IA gain per IAOUT=2(IAIN+\u2212IAIN\u2212)/RGAIN"+        "description": "Instrumentation Amplifier Gain Resistor connection point; external resistor determines IA gain per IAOUT=2(IAIN+−IAIN−)/RGAIN"       },       {         "number": "11",-        "name": "V\u2212",+        "name": "V−",         "type": "power_in",-        "description": "Negative Power Supply; operating voltage range \u00b15V to \u00b122V; must connect exposed thermal pad to this pin"+        "description": "Negative Power Supply; operating voltage range ±5V to ±22V; must connect exposed thermal pad to this pin"       },       {         "number": "12",@@ -110,7 +110,7 @@         "number": "13",         "name": "DRV",         "type": "output",-        "description": "Operational Amplifier Output; voltage swing (V\u2212)+3V to (V+)\u22123V; short-circuit current \u00b115mA to \u00b124mA depending on mode"+        "description": "Operational Amplifier Output; voltage swing (V−)+3V to (V+)−3V; short-circuit current ±15mA to ±24mA depending on mode"       },       {         "number": "14",@@ -122,37 +122,37 @@         "number": "15",         "name": "V+",         "type": "power_in",-        "description": "Positive Power Supply; operating voltage range \u00b15V to \u00b122V; absolute maximum +44V"+        "description": "Positive Power Supply; operating voltage range ±5V to ±22V; absolute maximum +44V"       },       {         "number": "16",         "name": "DGND",         "type": "power_in",-        "description": "Ground for Digital I/O; must be within (V\u2212) \u2264 DGND \u2264 (V+)\u22127V; carries digital output sink current"+        "description": "Ground for Digital I/O; must be within (V−) ≤ DGND ≤ (V+)−7V; carries digital output sink current"       },       {         "number": "17",         "name": "EFCM",         "type": "output",-        "description": "Error Flag for Common-Mode Over-Range, Active Low; open-drain output with internal 1\u03bcA pull-up; indicates IA input exceeds linear range"+        "description": "Error Flag for Common-Mode Over-Range, Active Low; open-drain output with internal 1μA pull-up; indicates IA input exceeds linear range"       },       {         "number": "18",         "name": "EFLD",         "type": "output",-        "description": "Error Flag for Load Error, Active Low; open-drain output with internal 1\u03bcA pull-up; indicates short-circuit or open-load condition"+        "description": "Error Flag for Load Error, Active Low; open-drain output with internal 1μA pull-up; indicates short-circuit or open-load condition"       },       {         "number": "19",         "name": "EFOT",         "type": "output",-        "description": "Error Flag for Over-Temperature, Active Low; open-drain output with internal 1\u03bcA pull-up; activates at +140\u00b0C, resets at +125\u00b0C"+        "description": "Error Flag for Over-Temperature, Active Low; open-drain output with internal 1μA pull-up; activates at +140°C, resets at +125°C"       },       {         "number": "20",         "name": "OD",         "type": "input",-        "description": "Output Disable, Disabled Low; digital input disables DRV output when driven low; internally pulled high with 1\u03bcA"+        "description": "Output Disable, Disabled Low; digital input disables DRV output when driven low; internally pulled high with 1μA"       },       {         "number": "21",@@ -239,5 +239,8 @@     "docs/xtr300airgwr-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file