← Commit history

Set visibility: public

Ray ·e75b3133c2 ·1mo ago ·parent a3499e6
1 file changed +15−12
page.json+15−12
@@ -32,13 +32,13 @@         "number": "1",         "name": "C1+",         "type": "passive",-        "description": "Positive lead of the C1 charge-pump flying capacitor. Connect an external 0.1 \u00b5F (VCC=3.3V) or 0.047 \u00b5F (VCC=5V) capacitor between C1+ and C1-."+        "description": "Positive lead of the C1 charge-pump flying capacitor. Connect an external 0.1 µF (VCC=3.3V) or 0.047 µF (VCC=5V) capacitor between C1+ and C1-."       },       {         "number": "2",         "name": "V+",         "type": "power_out",-        "description": "Positive charge-pump output (~+5.4 V typical) for the storage capacitor only. Connect a 0.1 \u00b5F (or 0.33 \u00b5F at 5V) capacitor from V+ to GND."+        "description": "Positive charge-pump output (~+5.4 V typical) for the storage capacitor only. Connect a 0.1 µF (or 0.33 µF at 5V) capacitor from V+ to GND."       },       {         "number": "3",@@ -50,7 +50,7 @@         "number": "4",         "name": "C2+",         "type": "passive",-        "description": "Positive lead of the C2 charge-pump flying capacitor. Connect an external 0.1 \u00b5F (0.33 \u00b5F at 5V) capacitor between C2+ and C2-."+        "description": "Positive lead of the C2 charge-pump flying capacitor. Connect an external 0.1 µF (0.33 µF at 5V) capacitor between C2+ and C2-."       },       {         "number": "5",@@ -62,19 +62,19 @@         "number": "6",         "name": "V-",         "type": "power_out",-        "description": "Negative charge-pump output (~-5.4 V typical) for the storage capacitor only. Connect a 0.1 \u00b5F (or 0.33 \u00b5F at 5V) capacitor from V- to GND."+        "description": "Negative charge-pump output (~-5.4 V typical) for the storage capacitor only. Connect a 0.1 µF (or 0.33 µF at 5V) capacitor from V- to GND."       },       {         "number": "7",         "name": "DOUT2",         "type": "output",-        "description": "RS-232 line driver output (channel 2) to the remote RS-232 system. Swings to approximately \u00b15 V with 3 k\u03a9 load; output resistance 300 \u03a9 min. \u00b115 kV IEC ESD protected."+        "description": "RS-232 line driver output (channel 2) to the remote RS-232 system. Swings to approximately ±5 V with 3 kΩ load; output resistance 300 Ω min. ±15 kV IEC ESD protected."       },       {         "number": "8",         "name": "RIN2",         "type": "input",-        "description": "RS-232 line receiver input (channel 2) from the remote RS-232 system. Accepts \u00b125 V input; input resistance 3-7 k\u03a9. \u00b115 kV IEC ESD protected."+        "description": "RS-232 line receiver input (channel 2) from the remote RS-232 system. Accepts ±25 V input; input resistance 3-7 kΩ. ±15 kV IEC ESD protected."       },       {         "number": "9",@@ -86,13 +86,13 @@         "number": "10",         "name": "DIN2",         "type": "input",-        "description": "Logic-level driver input (channel 2) from the UART/host. Accepts 3.3 V or 5 V CMOS logic; VIH \u2265 2 V (3.3 V VCC)."+        "description": "Logic-level driver input (channel 2) from the UART/host. Accepts 3.3 V or 5 V CMOS logic; VIH ≥ 2 V (3.3 V VCC)."       },       {         "number": "11",         "name": "DIN1",         "type": "input",-        "description": "Logic-level driver input (channel 1) from the UART/host. Accepts 3.3 V or 5 V CMOS logic; VIH \u2265 2 V (3.3 V VCC)."+        "description": "Logic-level driver input (channel 1) from the UART/host. Accepts 3.3 V or 5 V CMOS logic; VIH ≥ 2 V (3.3 V VCC)."       },       {         "number": "12",@@ -104,13 +104,13 @@         "number": "13",         "name": "RIN1",         "type": "input",-        "description": "RS-232 line receiver input (channel 1) from the remote RS-232 system. Accepts \u00b125 V input; input resistance 3-7 k\u03a9. \u00b115 kV IEC ESD protected."+        "description": "RS-232 line receiver input (channel 1) from the remote RS-232 system. Accepts ±25 V input; input resistance 3-7 kΩ. ±15 kV IEC ESD protected."       },       {         "number": "14",         "name": "DOUT1",         "type": "output",-        "description": "RS-232 line driver output (channel 1) to the remote RS-232 system. Swings to approximately \u00b15 V with 3 k\u03a9 load; output resistance 300 \u03a9 min. \u00b115 kV IEC ESD protected."+        "description": "RS-232 line driver output (channel 1) to the remote RS-232 system. Swings to approximately ±5 V with 3 kΩ load; output resistance 300 Ω min. ±15 kV IEC ESD protected."       },       {         "number": "15",@@ -122,7 +122,7 @@         "number": "16",         "name": "VCC",         "type": "power_in",-        "description": "Primary supply voltage. Connect to an external 3.0 V to 5.5 V rail; typical ICC = 300 \u00b5A. Bypass with a \u22651 \u00b5F capacitor to GND to meet IEC 61000-4-2 rating."+        "description": "Primary supply voltage. Connect to an external 3.0 V to 5.5 V rail; typical ICC = 300 µA. Bypass with a ≥1 µF capacitor to GND to meet IEC 61000-4-2 rating."       }     ],     "provenance": {@@ -186,5 +186,8 @@     "docs/trs3232eidr-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file