← Commit history

tps7101qp: specified limits as data (metadata.characteristics, 53 rows from the datasheet)

Ray ·9ba80de0fe ·17d ago ·parent 4344ae5
2 files changed +704−1
README.md+60
@@ -26,6 +26,66 @@ TPS7101QP from Texas Instruments, in a PDIP-8. Pinout and pin descriptions extra | Category | Power Management (PMIC) | | Pins | 8 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Input voltage, TPS7101Q | VI | 2.5 |  | 10 | V | TPS7101Q | 5 |+| High-level input voltage at EN | VIH | 2 |  |  | V |  | 5 |+| Low-level input voltage at EN | VIL |  |  | 0.5 | V |  | 5 |+| Output current range | IO | 0 |  | 500 | mA |  | 5 |+| Operating virtual junction temperature range | TJ | -40 |  | 125 | °C |  | 5 |+| Input voltage range (VI, PG, SENSE, EN) | VI | -0.3 |  | 11 | V | With respect to network terminal ground | 4 |+| Output current | IO |  |  | 2 | A |  | 4 |+| Operating virtual junction temperature range | TJ | -55 |  | 150 | °C |  | 4 |+| Storage temperature range | Tstg | -65 |  | 150 | °C |  | 4 |+| Lead temperature |  |  |  | 260 | °C | 1.6 mm (1/16 inch) from case for 10 seconds | 4 |+| Continuous total power dissipation, P package |  |  |  | 1175 | mW | P package, TA ≤ 25°C (free-air); derate 9.4 mW/°C above 25°C | 4 |+| Continuous total power dissipation, P package |  |  |  | 2738 | mW | P package, TC ≤ 25°C (case); derate 21.9 mW/°C above 25°C | 4 |+| Thermal resistance junction-to-ambient, P package | RθJA |  | 106 |  | °C/W | P package | 5 |+| Thermal resistance junction-to-case, P package | RθJC |  | 46 |  | °C/W | P package | 5 |+| Ground current (active mode) |  |  | 285 | 350 | µA | EN ≤ 0.5 V, VI = VO + 1 V, 25°C | 6 |+| Ground current (active mode) |  |  |  | 460 | µA | EN ≤ 0.5 V, 0 mA ≤ IO ≤ 500 mA, VI ≥ VO + 1 V, –40°C to 125°C | 6 |+| Input current (standby mode) |  |  |  | 0.5 | µA | 2.7 V ≤ VI ≤ 10 V, 25°C | 6 |+| Input current (standby mode) |  |  |  | 2 | µA | EN = VI, 2.7 V ≤ VI ≤ 10 V, –40°C to 125°C | 6 |+| Output current limit |  |  | 1.2 | 2 | A | VO = 0, VI = 10 V, 25°C | 6 |+| Output current limit |  |  |  | 2 | A | VO = 0, VI = 10 V, –40°C to 125°C | 6 |+| Pass-element leakage current in standby mode |  |  |  | 0.5 | µA | 2.7 V ≤ VI ≤ 10 V, 25°C | 6 |+| Pass-element leakage current in standby mode |  |  |  | 1 | µA | EN = VI, 2.7 V ≤ VI ≤ 10 V, –40°C to 125°C | 6 |+| PG leakage current |  |  | 0.02 | 0.5 | µA | Normal operation, VPG = 10 V, 25°C | 6 |+| PG leakage current |  |  |  | 0.5 | µA | Normal operation, VPG = 10 V, –40°C to 125°C | 6 |+| Output voltage temperature coefficient |  |  | 61 | 75 | ppm/°C | –40°C to 125°C | 6 |+| EN logic high (standby mode) |  | 2 |  |  | V | 2.5 V ≤ VI ≤ 6 V, –40°C to 125°C | 6 |+| EN logic high (standby mode) |  | 2.7 |  |  | V | 6 V ≤ VI ≤ 10 V, –40°C to 125°C | 6 |+| EN logic low (active mode) |  |  |  | 0.5 | V | 2.7 V ≤ VI ≤ 10 V, 25°C | 6 |+| EN input current |  | -0.5 |  | 0.5 | µA | 0 V ≤ VI ≤ 10 V, 25°C | 6 |+| Minimum VI for active pass element |  |  | 2.05 | 2.5 | V | 25°C | 6 |+| Minimum VI for active pass element |  |  |  | 2.5 | V | –40°C to 125°C | 6 |+| Minimum VI for valid PG |  |  | 1.06 | 1.5 | V | IPG = 300 µA, 25°C | 6 |+| Minimum VI for valid PG |  |  |  | 1.9 | V | IPG = 300 µA, –40°C to 125°C | 6 |+| Thermal shutdown junction temperature |  |  | 165 |  | °C |  | 6 |+| Reference voltage (measured at FB with OUT connected to FB) |  | 1.143 |  | 1.213 | V | 2.5 V ≤ VI ≤ 10 V, 5 mA ≤ IO ≤ 500 mA, –40°C to 125°C | 7 |+| Reference voltage temperature coefficient |  |  | 61 | 75 | ppm/°C | –40°C to 125°C | 7 |+| Pass-element series resistance |  |  | 0.7 | 1 | Ω | VI = 2.4 V, 50 µA ≤ IO ≤ 150 mA, 25°C | 7 |+| Pass-element series resistance |  |  |  | 1 | Ω | VI = 2.4 V, 50 µA ≤ IO ≤ 150 mA, –40°C to 125°C | 7 |+| Pass-element series resistance |  |  | 0.83 | 1.3 | Ω | VI = 2.4 V, 150 mA ≤ IO ≤ 500 mA, 25°C | 7 |+| Pass-element series resistance |  |  |  | 1.3 | Ω | VI = 2.4 V, 150 mA ≤ IO ≤ 500 mA, –40°C to 125°C | 7 |+| Pass-element series resistance |  |  | 0.52 | 0.85 | Ω | VI = 2.9 V, 50 µA ≤ IO ≤ 500 mA, 25°C | 7 |+| Pass-element series resistance |  |  |  | 0.85 | Ω | VI = 2.9 V, 50 µA ≤ IO ≤ 500 mA, –40°C to 125°C | 7 |+| Input regulation |  |  |  | 25 | mV | VI = 2.5 V to 10 V, 50 µA ≤ IO ≤ 500 mA, –40°C to 125°C | 7 |+| Output regulation |  |  |  | 25 | mV | IO = 5 mA to 500 mA, 2.5 V ≤ VI ≤ 10 V, –40°C to 125°C | 7 |+| Output regulation |  |  |  | 54 | mV | IO = 50 µA to 500 mA, 2.5 V ≤ VI ≤ 10 V, –40°C to 125°C | 7 |+| Ripple rejection |  | 48 | 59 |  | dB | f = 120 Hz, IO = 50 µA, 25°C | 7 |+| Ripple rejection |  | 44 |  |  | dB | f = 120 Hz, IO = 50 µA, –40°C to 125°C | 7 |+| Ripple rejection |  | 45 | 54 |  | dB | f = 120 Hz, IO = 500 mA, 25°C | 7 |+| PG trip-threshold voltage | VPG | 1.101 |  | 1.145 | V | VFB voltage decreasing from above VPG, –40°C to 125°C | 7 |+| PG output low voltage |  |  | 0.1 | 0.4 | V | IPG = 400 µA, VI = 2.13 V, 25°C | 7 |+| PG output low voltage |  |  |  | 0.4 | V | IPG = 400 µA, VI = 2.13 V, –40°C to 125°C | 7 |+| FB input current |  | -10 | 0.1 | 10 | nA | 25°C | 7 |+| FB input current |  | -20 |  | 20 | nA | –40°C to 125°C | 7 |+ ## CAD (KiCad official)  - Symbol: `TPS7101QP`
page.json+644−1
@@ -180,6 +180,649 @@       "Package": "PDIP-8",       "Category": "Power Management (PMIC)",       "Pins": "8"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "6da6cbc880c8f130",+      "rows": [+        {+          "name": "Input voltage, TPS7101Q",+          "symbol": "VI",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 2.5,+          "typ": null,+          "max": 10,+          "conditions": "TPS7101Q",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "High-level input voltage at EN",+          "symbol": "VIH",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 2,+          "typ": null,+          "max": null,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Low-level input voltage at EN",+          "symbol": "VIL",+          "kind": "recommended_operating",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.5,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Output current range",+          "symbol": "IO",+          "kind": "recommended_operating",+          "unit": "mA",+          "min": 0,+          "typ": null,+          "max": 500,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Operating virtual junction temperature range",+          "symbol": "TJ",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range (VI, PG, SENSE, EN)",+          "symbol": "VI",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 11,+          "conditions": "With respect to network terminal ground",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Output current",+          "symbol": "IO",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 2,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Operating virtual junction temperature range",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature range",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Lead temperature",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "1.6 mm (1/16 inch) from case for 10 seconds",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Continuous total power dissipation, P package",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "mW",+          "min": null,+          "typ": null,+          "max": 1175,+          "conditions": "P package, TA ≤ 25°C (free-air); derate 9.4 mW/°C above 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Continuous total power dissipation, P package",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW",+          "min": null,+          "typ": null,+          "max": 2738,+          "conditions": "P package, TC ≤ 25°C (case); derate 21.9 mW/°C above 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Thermal resistance junction-to-ambient, P package",+          "symbol": "RθJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 106,+          "max": null,+          "conditions": "P package",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Thermal resistance junction-to-case, P package",+          "symbol": "RθJC",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 46,+          "max": null,+          "conditions": "P package",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Ground current (active mode)",+          "symbol": "",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": 285,+          "max": 350,+          "conditions": "EN ≤ 0.5 V, VI = VO + 1 V, 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Ground current (active mode)",+          "symbol": "",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 460,+          "conditions": "EN ≤ 0.5 V, 0 mA ≤ IO ≤ 500 mA, VI ≥ VO + 1 V, –40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Input current (standby mode)",+          "symbol": "",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 0.5,+          "conditions": "2.7 V ≤ VI ≤ 10 V, 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Input current (standby mode)",+          "symbol": "",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 2,+          "conditions": "EN = VI, 2.7 V ≤ VI ≤ 10 V, –40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Output current limit",+          "symbol": "",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 1.2,+          "max": 2,+          "conditions": "VO = 0, VI = 10 V, 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Output current limit",+          "symbol": "",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 2,+          "conditions": "VO = 0, VI = 10 V, –40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Pass-element leakage current in standby mode",+          "symbol": "",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 0.5,+          "conditions": "2.7 V ≤ VI ≤ 10 V, 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Pass-element leakage current in standby mode",+          "symbol": "",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "EN = VI, 2.7 V ≤ VI ≤ 10 V, –40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "PG leakage current",+          "symbol": "",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": 0.02,+          "max": 0.5,+          "conditions": "Normal operation, VPG = 10 V, 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "PG leakage current",+          "symbol": "",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 0.5,+          "conditions": "Normal operation, VPG = 10 V, –40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Output voltage temperature coefficient",+          "symbol": "",+          "kind": "temperature_coefficient",+          "unit": "ppm/°C",+          "min": null,+          "typ": 61,+          "max": 75,+          "conditions": "–40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "EN logic high (standby mode)",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": 2,+          "typ": null,+          "max": null,+          "conditions": "2.5 V ≤ VI ≤ 6 V, –40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "EN logic high (standby mode)",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": 2.7,+          "typ": null,+          "max": null,+          "conditions": "6 V ≤ VI ≤ 10 V, –40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "EN logic low (active mode)",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.5,+          "conditions": "2.7 V ≤ VI ≤ 10 V, 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "EN input current",+          "symbol": "",+          "kind": "electrical",+          "unit": "µA",+          "min": -0.5,+          "typ": null,+          "max": 0.5,+          "conditions": "0 V ≤ VI ≤ 10 V, 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Minimum VI for active pass element",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": 2.05,+          "max": 2.5,+          "conditions": "25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Minimum VI for active pass element",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 2.5,+          "conditions": "–40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Minimum VI for valid PG",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": 1.06,+          "max": 1.5,+          "conditions": "IPG = 300 µA, 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Minimum VI for valid PG",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1.9,+          "conditions": "IPG = 300 µA, –40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Thermal shutdown junction temperature",+          "symbol": "",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": 165,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Reference voltage (measured at FB with OUT connected to FB)",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": 1.143,+          "typ": null,+          "max": 1.213,+          "conditions": "2.5 V ≤ VI ≤ 10 V, 5 mA ≤ IO ≤ 500 mA, –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Reference voltage temperature coefficient",+          "symbol": "",+          "kind": "temperature_coefficient",+          "unit": "ppm/°C",+          "min": null,+          "typ": 61,+          "max": 75,+          "conditions": "–40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Pass-element series resistance",+          "symbol": "",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.7,+          "max": 1,+          "conditions": "VI = 2.4 V, 50 µA ≤ IO ≤ 150 mA, 25°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Pass-element series resistance",+          "symbol": "",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "VI = 2.4 V, 50 µA ≤ IO ≤ 150 mA, –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Pass-element series resistance",+          "symbol": "",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.83,+          "max": 1.3,+          "conditions": "VI = 2.4 V, 150 mA ≤ IO ≤ 500 mA, 25°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Pass-element series resistance",+          "symbol": "",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 1.3,+          "conditions": "VI = 2.4 V, 150 mA ≤ IO ≤ 500 mA, –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Pass-element series resistance",+          "symbol": "",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.52,+          "max": 0.85,+          "conditions": "VI = 2.9 V, 50 µA ≤ IO ≤ 500 mA, 25°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Pass-element series resistance",+          "symbol": "",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 0.85,+          "conditions": "VI = 2.9 V, 50 µA ≤ IO ≤ 500 mA, –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Input regulation",+          "symbol": "",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": null,+          "max": 25,+          "conditions": "VI = 2.5 V to 10 V, 50 µA ≤ IO ≤ 500 mA, –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Output regulation",+          "symbol": "",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": null,+          "max": 25,+          "conditions": "IO = 5 mA to 500 mA, 2.5 V ≤ VI ≤ 10 V, –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Output regulation",+          "symbol": "",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": null,+          "max": 54,+          "conditions": "IO = 50 µA to 500 mA, 2.5 V ≤ VI ≤ 10 V, –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Ripple rejection",+          "symbol": "",+          "kind": "electrical",+          "unit": "dB",+          "min": 48,+          "typ": 59,+          "max": null,+          "conditions": "f = 120 Hz, IO = 50 µA, 25°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Ripple rejection",+          "symbol": "",+          "kind": "electrical",+          "unit": "dB",+          "min": 44,+          "typ": null,+          "max": null,+          "conditions": "f = 120 Hz, IO = 50 µA, –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Ripple rejection",+          "symbol": "",+          "kind": "electrical",+          "unit": "dB",+          "min": 45,+          "typ": 54,+          "max": null,+          "conditions": "f = 120 Hz, IO = 500 mA, 25°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "PG trip-threshold voltage",+          "symbol": "VPG",+          "kind": "electrical",+          "unit": "V",+          "min": 1.101,+          "typ": null,+          "max": 1.145,+          "conditions": "VFB voltage decreasing from above VPG, –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "PG output low voltage",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": 0.1,+          "max": 0.4,+          "conditions": "IPG = 400 µA, VI = 2.13 V, 25°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "PG output low voltage",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.4,+          "conditions": "IPG = 400 µA, VI = 2.13 V, –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "FB input current",+          "symbol": "",+          "kind": "electrical",+          "unit": "nA",+          "min": -10,+          "typ": 0.1,+          "max": 10,+          "conditions": "25°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "FB input current",+          "symbol": "",+          "kind": "electrical",+          "unit": "nA",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "–40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -221,4 +864,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}