← Commit history

tps53127rger: specified limits as data (metadata.characteristics, 60 rows from the datasheet)

Ray ·e9552405bc ·16d ago ·parent 3c09edb
2 files changed +795−1
README.md+67
@@ -43,6 +43,73 @@ TPS53127RGER from Texas Instruments, in a VQFN-24-EP(4x4). Pinout and pin descri | Category | Power Management (PMIC) | | Pins | 25 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| VIN supply input voltage | VIN | 4.5 |  | 24 | V |  | 4 |+| V5FILT supply input voltage | V5FILT | 4.5 |  | 5.5 | V |  | 4 |+| VBST bootstrap voltage | VBST1, VBST2 | -0.1 |  | 30 | V |  | 4 |+| VBST to SW voltage | VBST1 - SW1, VBST2 - SW2 | -0.1 |  | 5.5 | V |  | 4 |+| Output/feedback input voltage | VFB1, VFB2, VO1, VO2 | -0.1 |  | 5.5 | V |  | 4 |+| TRIP input voltage | TRIP1, TRIP2 | -0.1 |  | 0.3 | V |  | 4 |+| Enable input voltage | EN1, EN2 | -0.1 |  | 24 | V |  | 4 |+| Switch node voltage | SW1, SW2 | -1.8 |  | 24 | V |  | 4 |+| DRVH output voltage | DRVH1, DRVH2 | -0.1 |  | 30 | V |  | 4 |+| DRVL, VREG5, SS output voltage | DRVL1, DRVL2, VREG5, SS1, SS2 | -0.1 |  | 5.5 | V |  | 4 |+| PGND voltage | PGND1, PGND2 | -0.1 |  | 0.1 | V |  | 4 |+| Operating free-air temperature | TA | -40 |  | 85 | °C |  | 4 |+| Operating junction temperature | TJ | -40 |  | 125 | °C |  | 4 |+| VIN, EN input voltage absolute maximum | VIN, EN1, EN2 | -0.3 |  | 26 | V |  | 4 |+| VBST absolute maximum | VBST1, VBST2 | -0.3 |  | 32 | V |  | 4 |+| VBST to SW absolute maximum | VBST1 - SW1, VBST2 - SW2 | -0.3 |  | 6 | V |  | 4 |+| Low-voltage input/output absolute maximum | V5FILT, VFB1, VFB2, TRIP1, TRIP2, VO1, VO2 | -0.3 |  | 6 | V |  | 4 |+| SW absolute maximum | SW1, SW2 | -2 |  | 26 | V |  | 4 |+| DRVH absolute maximum | DRVH1, DRVH2 | -1 |  | 32 | V |  | 4 |+| DRVH to SW absolute maximum | DRVH1 - SW1, DRVH2 - SW2 | -0.3 |  | 6 | V |  | 4 |+| DRVL, VREG5, SS absolute maximum | DRVL1, DRVL2, VREG5, SS1, SS2 | -0.3 |  | 6 | V |  | 4 |+| PGND absolute maximum | PGND1, PGND2 | -0.3 |  | 0.3 | V |  | 4 |+| Operating free-air temperature absolute maximum | TA | -40 |  | 85 | °C |  | 4 |+| Junction temperature absolute maximum | TJ | -40 |  | 150 | °C |  | 4 |+| VIN supply current | IIN |  | 450 | 800 | μA | TA = 25°C, VREG5 tied to V5FILT, EN1 = EN2 = 5 V, VFB1 = VFB2 = 0.8 V, SW1 = SW2 = 0.5 V | 5 |+| VIN shutdown current | I(VINSDN) |  | 30 | 60 | μA | TA = 25°C, no load, EN1 = EN2 = 0 V, VREG5 = ON | 5 |+| VFBx threshold voltage | V(VFBTHx) | 748 | 758 | 768 | mV | TA = 25°C, SWinj = OFF | 5 |+| VFBx threshold voltage | V(VFBTHx) | 746.6 |  | 769.4 | mV | TA = 0°C to 70°C, SWinj = OFF | 5 |+| VFBx threshold voltage | V(VFBTHx) | 745 |  | 771 | mV | TA = -40°C to 85°C, SWinj = OFF | 5 |+| VFB input current | I(VFB) | -100 | -10 | 100 | nA | VFBx = 0.8 V, TA = 25°C | 5 |+| VO discharge resistance | R(Dischg) | 40 |  | 80 | Ω | ENx = 0 V, VOx = 0.5 V, TA = 25°C | 5 |+| VREG5 output voltage | V(VREG)5 | 4.6 | 5 | 5.2 | V | TA = 25°C, 5.5 V < VIN < 24 V, 0 < I(VREG5) < 10 mA | 5 |+| DRVH resistance, source | R(DRVH) | 5.5 |  | 11 | Ω | Source, I(DRVHx) = –100 mA | 5 |+| DRVH resistance, sink | R(DRVH) | 2.5 |  | 5 | Ω | Sink, I(DRVHx) = 100 mA | 5 |+| DRVL resistance, source | R(DRVL) | 4 |  | 12 | Ω | Source, I(DRVLx) = –100 mA | 5 |+| DRVL resistance, sink | R(DRVL) | 2 |  | 4 | Ω | Sink, I(DRVLx) = 100 mA | 5 |+| Internal boost diode forward voltage | V(FBST) | 0.7 | 0.8 | 0.9 | V | IF = 10 mA, TA = 25°C | 5 |+| VBST leakage current | I(VBSTLK) | 0.1 |  | 1 | μA | VBSTx = 29 V, SWx = 24 V, TA = 25°C | 5 |+| SS1/SS2 charge current | I(SSC) | -2.5 | -2 | -1.5 | μA | VSS1/VSS2 = 0 V, TA = 25°C | 6 |+| ISSC temperature coefficient | TC(ISSC) | -4 |  | 3 | nA/°C | On the basis of 25°C | 6 |+| SS1/SS2 discharge current | ISSD | 100 |  | 150 | μA | VSS1/VSS2 = 0.5 V | 6 |+| V5FILT UVLO threshold (wake up) | V(UV5VFILT) | 3.7 | 4 | 4.3 | V | Wake up | 6 |+| TRIP source current | I(TRIP) | 8.5 | 10 | 11.5 | μA | V(TRIPx) = 0.1 V, TA = 25°C | 6 |+| OCP compensation offset | VOC(Loff) | -15 | 0 | 15 | mV | V(TRIPx-GND) = 60 mV, TA = 25°C | 6 |+| OCP compensation offset | VOC(Loff) | -20 |  | 20 | mV | V(TRIPx-GND) = 60 mV | 6 |+| Current limit threshold setting range | VR(trip) | 30 |  | 300 | mV | V(TRIPx-GND) voltage | 6 |+| Output OVP trip threshold | VOVP | 110 | 115 | 120 | % | OVP detect | 6 |+| Output UVP trip threshold | VUVP | 65 | 70 | 75 | % | UVP detect | 6 |+| ITRIP temperature coefficient | TC(ITRIP) |  | 4000 |  | ppm/°C | On the basis of 25°C | 6 |+| ENx high-level input voltage | V(ENH) |  | 2 |  | V | EN 1/2 | 6 |+| Thermal shutdown threshold | TSDN |  | 150 |  | °C | Shutdown temperature | 6 |+| DRVHx-low to DRVLx-on dead time | tD | 20 | 50 | 80 | ns |  | 6 |+| DRVLx-low to DRVHx-on dead time | tD | 20 | 40 | 80 | ns |  | 6 |+| Output UVP delay | tUVPDEL | 17 | 30 | 40 | µs |  | 6 |+| UVP enable delay / soft-start time multiplier | tUVPEN | 1.4 | 1.7 | 2 | x (soft-start time) |  | 6 |+| Output OVP propagation delay | tOVPDEL |  | 1.5 |  | µs |  | 6 |+| CH1 on time | tON1L |  | 165 |  | ns | SW1 = 12 V, VO1 = 1.8 V | 6 |+| CH2 on time | tON2L |  | 140 |  | ns | SW2 = 12 V, VO2 = 1.8 V | 6 |+| Junction-to-ambient thermal resistance (RGE) | RθJA |  | 35.4 |  | °C/W |  | 5 |+| Junction-to-case (bottom) thermal resistance (RGE) | RθJC(bot) |  | 3.8 |  | °C/W |  | 5 |+ ## CAD (KiCad official)  - Symbol: `TPS53127RGER`
page.json+728−1
@@ -283,6 +283,733 @@       "Package": "VQFN-24-EP(4x4)",       "Category": "Power Management (PMIC)",       "Pins": "25"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "d7c5b2760d0a2f0e",+      "rows": [+        {+          "name": "VIN supply input voltage",+          "symbol": "VIN",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 4.5,+          "typ": null,+          "max": 24,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "V5FILT supply input voltage",+          "symbol": "V5FILT",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 4.5,+          "typ": null,+          "max": 5.5,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VBST bootstrap voltage",+          "symbol": "VBST1, VBST2",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 30,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VBST to SW voltage",+          "symbol": "VBST1 - SW1, VBST2 - SW2",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 5.5,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Output/feedback input voltage",+          "symbol": "VFB1, VFB2, VO1, VO2",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 5.5,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "TRIP input voltage",+          "symbol": "TRIP1, TRIP2",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 0.3,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Enable input voltage",+          "symbol": "EN1, EN2",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 24,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Switch node voltage",+          "symbol": "SW1, SW2",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -1.8,+          "typ": null,+          "max": 24,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "DRVH output voltage",+          "symbol": "DRVH1, DRVH2",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 30,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "DRVL, VREG5, SS output voltage",+          "symbol": "DRVL1, DRVL2, VREG5, SS1, SS2",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 5.5,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "PGND voltage",+          "symbol": "PGND1, PGND2",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 0.1,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Operating free-air temperature",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Operating junction temperature",+          "symbol": "TJ",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VIN, EN input voltage absolute maximum",+          "symbol": "VIN, EN1, EN2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 26,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VBST absolute maximum",+          "symbol": "VBST1, VBST2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 32,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VBST to SW absolute maximum",+          "symbol": "VBST1 - SW1, VBST2 - SW2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 6,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Low-voltage input/output absolute maximum",+          "symbol": "V5FILT, VFB1, VFB2, TRIP1, TRIP2, VO1, VO2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 6,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "SW absolute maximum",+          "symbol": "SW1, SW2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -2,+          "typ": null,+          "max": 26,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "DRVH absolute maximum",+          "symbol": "DRVH1, DRVH2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -1,+          "typ": null,+          "max": 32,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "DRVH to SW absolute maximum",+          "symbol": "DRVH1 - SW1, DRVH2 - SW2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 6,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "DRVL, VREG5, SS absolute maximum",+          "symbol": "DRVL1, DRVL2, VREG5, SS1, SS2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 6,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "PGND absolute maximum",+          "symbol": "PGND1, PGND2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 0.3,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Operating free-air temperature absolute maximum",+          "symbol": "TA",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Junction temperature absolute maximum",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VIN supply current",+          "symbol": "IIN",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": 450,+          "max": 800,+          "conditions": "TA = 25°C, VREG5 tied to V5FILT, EN1 = EN2 = 5 V, VFB1 = VFB2 = 0.8 V, SW1 = SW2 = 0.5 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "VIN shutdown current",+          "symbol": "I(VINSDN)",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": 30,+          "max": 60,+          "conditions": "TA = 25°C, no load, EN1 = EN2 = 0 V, VREG5 = ON",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "VFBx threshold voltage",+          "symbol": "V(VFBTHx)",+          "kind": "electrical",+          "unit": "mV",+          "min": 748,+          "typ": 758,+          "max": 768,+          "conditions": "TA = 25°C, SWinj = OFF",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "VFBx threshold voltage",+          "symbol": "V(VFBTHx)",+          "kind": "electrical",+          "unit": "mV",+          "min": 746.6,+          "typ": null,+          "max": 769.4,+          "conditions": "TA = 0°C to 70°C, SWinj = OFF",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "VFBx threshold voltage",+          "symbol": "V(VFBTHx)",+          "kind": "electrical",+          "unit": "mV",+          "min": 745,+          "typ": null,+          "max": 771,+          "conditions": "TA = -40°C to 85°C, SWinj = OFF",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "VFB input current",+          "symbol": "I(VFB)",+          "kind": "electrical",+          "unit": "nA",+          "min": -100,+          "typ": -10,+          "max": 100,+          "conditions": "VFBx = 0.8 V, TA = 25°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "VO discharge resistance",+          "symbol": "R(Dischg)",+          "kind": "electrical",+          "unit": "Ω",+          "min": 40,+          "typ": null,+          "max": 80,+          "conditions": "ENx = 0 V, VOx = 0.5 V, TA = 25°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "VREG5 output voltage",+          "symbol": "V(VREG)5",+          "kind": "electrical",+          "unit": "V",+          "min": 4.6,+          "typ": 5,+          "max": 5.2,+          "conditions": "TA = 25°C, 5.5 V < VIN < 24 V, 0 < I(VREG5) < 10 mA",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "DRVH resistance, source",+          "symbol": "R(DRVH)",+          "kind": "electrical",+          "unit": "Ω",+          "min": 5.5,+          "typ": null,+          "max": 11,+          "conditions": "Source, I(DRVHx) = –100 mA",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "DRVH resistance, sink",+          "symbol": "R(DRVH)",+          "kind": "electrical",+          "unit": "Ω",+          "min": 2.5,+          "typ": null,+          "max": 5,+          "conditions": "Sink, I(DRVHx) = 100 mA",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "DRVL resistance, source",+          "symbol": "R(DRVL)",+          "kind": "electrical",+          "unit": "Ω",+          "min": 4,+          "typ": null,+          "max": 12,+          "conditions": "Source, I(DRVLx) = –100 mA",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "DRVL resistance, sink",+          "symbol": "R(DRVL)",+          "kind": "electrical",+          "unit": "Ω",+          "min": 2,+          "typ": null,+          "max": 4,+          "conditions": "Sink, I(DRVLx) = 100 mA",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Internal boost diode forward voltage",+          "symbol": "V(FBST)",+          "kind": "electrical",+          "unit": "V",+          "min": 0.7,+          "typ": 0.8,+          "max": 0.9,+          "conditions": "IF = 10 mA, TA = 25°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "VBST leakage current",+          "symbol": "I(VBSTLK)",+          "kind": "electrical",+          "unit": "μA",+          "min": 0.1,+          "typ": null,+          "max": 1,+          "conditions": "VBSTx = 29 V, SWx = 24 V, TA = 25°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "SS1/SS2 charge current",+          "symbol": "I(SSC)",+          "kind": "electrical",+          "unit": "μA",+          "min": -2.5,+          "typ": -2,+          "max": -1.5,+          "conditions": "VSS1/VSS2 = 0 V, TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "ISSC temperature coefficient",+          "symbol": "TC(ISSC)",+          "kind": "temperature_coefficient",+          "unit": "nA/°C",+          "min": -4,+          "typ": null,+          "max": 3,+          "conditions": "On the basis of 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "SS1/SS2 discharge current",+          "symbol": "ISSD",+          "kind": "electrical",+          "unit": "μA",+          "min": 100,+          "typ": null,+          "max": 150,+          "conditions": "VSS1/VSS2 = 0.5 V",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "V5FILT UVLO threshold (wake up)",+          "symbol": "V(UV5VFILT)",+          "kind": "electrical",+          "unit": "V",+          "min": 3.7,+          "typ": 4,+          "max": 4.3,+          "conditions": "Wake up",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "TRIP source current",+          "symbol": "I(TRIP)",+          "kind": "electrical",+          "unit": "μA",+          "min": 8.5,+          "typ": 10,+          "max": 11.5,+          "conditions": "V(TRIPx) = 0.1 V, TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "OCP compensation offset",+          "symbol": "VOC(Loff)",+          "kind": "electrical",+          "unit": "mV",+          "min": -15,+          "typ": 0,+          "max": 15,+          "conditions": "V(TRIPx-GND) = 60 mV, TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "OCP compensation offset",+          "symbol": "VOC(Loff)",+          "kind": "electrical",+          "unit": "mV",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "V(TRIPx-GND) = 60 mV",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Current limit threshold setting range",+          "symbol": "VR(trip)",+          "kind": "electrical",+          "unit": "mV",+          "min": 30,+          "typ": null,+          "max": 300,+          "conditions": "V(TRIPx-GND) voltage",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Output OVP trip threshold",+          "symbol": "VOVP",+          "kind": "electrical",+          "unit": "%",+          "min": 110,+          "typ": 115,+          "max": 120,+          "conditions": "OVP detect",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Output UVP trip threshold",+          "symbol": "VUVP",+          "kind": "electrical",+          "unit": "%",+          "min": 65,+          "typ": 70,+          "max": 75,+          "conditions": "UVP detect",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "ITRIP temperature coefficient",+          "symbol": "TC(ITRIP)",+          "kind": "temperature_coefficient",+          "unit": "ppm/°C",+          "min": null,+          "typ": 4000,+          "max": null,+          "conditions": "On the basis of 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "ENx high-level input voltage",+          "symbol": "V(ENH)",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": 2,+          "max": null,+          "conditions": "EN 1/2",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Thermal shutdown threshold",+          "symbol": "TSDN",+          "kind": "electrical",+          "unit": "°C",+          "min": null,+          "typ": 150,+          "max": null,+          "conditions": "Shutdown temperature",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "DRVHx-low to DRVLx-on dead time",+          "symbol": "tD",+          "kind": "timing",+          "unit": "ns",+          "min": 20,+          "typ": 50,+          "max": 80,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "DRVLx-low to DRVHx-on dead time",+          "symbol": "tD",+          "kind": "timing",+          "unit": "ns",+          "min": 20,+          "typ": 40,+          "max": 80,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Output UVP delay",+          "symbol": "tUVPDEL",+          "kind": "timing",+          "unit": "µs",+          "min": 17,+          "typ": 30,+          "max": 40,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "UVP enable delay / soft-start time multiplier",+          "symbol": "tUVPEN",+          "kind": "timing",+          "unit": "x (soft-start time)",+          "min": 1.4,+          "typ": 1.7,+          "max": 2,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Output OVP propagation delay",+          "symbol": "tOVPDEL",+          "kind": "timing",+          "unit": "µs",+          "min": null,+          "typ": 1.5,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "CH1 on time",+          "symbol": "tON1L",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 165,+          "max": null,+          "conditions": "SW1 = 12 V, VO1 = 1.8 V",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "CH2 on time",+          "symbol": "tON2L",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 140,+          "max": null,+          "conditions": "SW2 = 12 V, VO2 = 1.8 V",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-ambient thermal resistance (RGE)",+          "symbol": "RθJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 35.4,+          "max": null,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-case (bottom) thermal resistance (RGE)",+          "symbol": "RθJC(bot)",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 3.8,+          "max": null,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -324,4 +1051,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}