← Commit history
tps51218dscr: specified limits as data (metadata.characteristics, 60 rows from the datasheet)
2 files changed
+794
README.md+67@@ -29,6 +29,73 @@ TPS51218DSCR from Texas Instruments, in a WSON-10-EP(3x3). Pinout and pin descri | Category | Power Management (PMIC) | | Pins | 11 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Input voltage range VBST | VBST | -0.3 | | 37 | V | | 2 |+| Input voltage range VBST (note 3, with respect to SW) | VBST | -0.3 | | 7 | V | with respect to SW terminal | 2 |+| Input voltage range SW | SW | -5 | | 30 | V | | 2 |+| Input voltage range V5IN, EN, TRIP, VFB, RF | V5IN, EN, TRIP, VFB, RF | -0.3 | | 7 | V | | 2 |+| Output voltage range DRVH | DRVH | -5 | | 37 | V | | 2 |+| Output voltage range DRVH (note 3, with respect to SW) | DRVH | -0.3 | | 7 | V | with respect to SW terminal | 2 |+| Output voltage range DRVH pulse | DRVH | -2.5 | | 7 | V | pulse width < 20 ns | 2 |+| Output voltage range DRVL | DRVL | -0.5 | | 7 | V | | 2 |+| Output voltage range DRVL pulse | DRVL | -2.5 | | 7 | V | pulse width < 20 ns | 2 |+| Output voltage range PGOOD | PGOOD | -0.3 | | 7 | V | | 2 |+| Junction temperature range | TJ | | | 150 | °C | | 2 |+| Storage temperature range | TSTG | -55 | | 150 | °C | | 2 |+| Supply voltage | V5IN | 4.5 | | 6.5 | V | | 3 |+| Input voltage range VBST | VBST | -0.1 | | 34.5 | V | | 3 |+| Input voltage range SW | SW | -1 | | 28 | V | | 3 |+| Input voltage range SW (note 1) | SW | -4 | | 28 | V | applied for less than 30% of the repetitive period | 3 |+| Input voltage range VBST (note 2, with respect to SW) | VBST | -0.1 | | 6.5 | V | with respect to SW terminal | 3 |+| Input voltage range EN, TRIP, VFB, RF | EN, TRIP, VFB, RF | -0.1 | | 6.5 | V | | 3 |+| Output voltage range DRVH | DRVH | -1 | | 34.5 | V | | 3 |+| Output voltage range DRVH (note 1) | DRVH | -4 | | 34.5 | V | applied for less than 30% of the repetitive period | 3 |+| Output voltage range DRVH (note 2, with respect to SW) | DRVH | -0.1 | | 6.5 | V | with respect to SW terminal | 3 |+| Output voltage range DRVL | DRVL | -0.3 | | 6.5 | V | | 3 |+| Output voltage range PGOOD | PGOOD | -0.1 | | 6.5 | V | | 3 |+| Operating free-air temperature | TA | -40 | | 85 | °C | | 3 |+| V5IN supply current | IV5IN | | 320 | 500 | μA | TA = 25°C, No Load, VEN = 5 V, VVFB = 0.735 V | 4 |+| VFB regulation voltage | VVFB | 0.7005 | 0.704 | 0.7075 | V | TA = 25°C, skip mode | 4 |+| VFB regulation voltage | VVFB | 0.6984 | 0.704 | 0.7096 | V | TA = 0°C to 85°C, skip mode | 4 |+| VFB regulation voltage | VVFB | 0.697 | 0.704 | 0.711 | V | TA = –40°C to 85°C, skip mode | 4 |+| VFB input current | IVFB | | 0.01 | 0.2 | μA | VVFB = 0.735 V, TA = 25°C, skip mode | 4 |+| Output discharge current from SW pin | IDischg | | 5 | 13 | mA | VEN = 0 V, VSW = 0.5 V | 4 |+| DRVH resistance (source) | RDRVH | | 1.5 | 3 | Ω | Source, IDRVH = –50 mA | 4 |+| DRVH resistance (sink) | RDRVH | | 0.7 | 1.8 | Ω | Sink, IDRVH = 50 mA | 4 |+| DRVL resistance (source) | RDRVL | | 1 | 2.2 | Ω | Source, IDRVL = –50 mA | 4 |+| DRVL resistance (sink) | RDRVL | | 0.5 | 1.2 | Ω | Sink, IDRVL = 50 mA | 4 |+| Dead time DRVH-off to DRVL-on | tD | 7 | 17 | 30 | ns | DRVH-off to DRVL-on | 4 |+| Dead time DRVL-off to DRVH-on | tD | 10 | 22 | 35 | ns | DRVL-off to DRVH-on | 4 |+| Minimum off-time | tOFF(min) | 150 | 260 | 400 | ns | TA = 25°C | 4 |+| PG threshold, PG in from lower | VTHPG | 92.5 | 95 | 97.5 | % | PG in from lower | 4 |+| PG threshold, PG in from higher | VTHPG | 107.5 | 110 | 112.5 | % | PG in from higher | 4 |+| PG delay | tPGDEL | 0.8 | 1 | 1.2 | ms | Delay for PG in | 4 |+| Switching frequency | fSW | 266 | 290 | 314 | kHz | RRF = 470 kΩ, TA = 25°C | 4 |+| Switching frequency | fSW | 312 | 340 | 368 | kHz | RRF = 200 kΩ, TA = 25°C | 4 |+| Switching frequency | fSW | 349 | 380 | 411 | kHz | RRF = 100 kΩ, TA = 25°C | 4 |+| Switching frequency | fSW | 395 | 430 | 465 | kHz | RRF = 39 kΩ, TA = 25°C | 4 |+| TRIP source current | ITRIP | 9 | 10 | 11 | μA | VTRIP = 1V, TA = 25°C | 5 |+| Current limit threshold setting range VTRIP-GND voltage | VTRIP | 0.2 | | 3 | V | VTRIP-GND voltage range | 5 |+| Current limit threshold | VOCL | 355 | 375 | 395 | mV | VTRIP = 3.0 V | 5 |+| Current limit threshold | VOCL | 185 | 200 | 215 | mV | VTRIP = 1.6 V | 5 |+| Current limit threshold | VOCL | 17 | 25 | 33 | mV | VTRIP = 0.2 V | 5 |+| Negative current limit threshold | VOCLN | -395 | -375 | -355 | mV | VTRIP = 3.0 V | 5 |+| Negative current limit threshold | VOCLN | -215 | -200 | -185 | mV | VTRIP = 1.6 V | 5 |+| Negative current limit threshold | VOCLN | -33 | -25 | -17 | mV | VTRIP = 0.2 V | 5 |+| Adaptive zero cross adjustable range | VAZCADJ | 3 | | 15 | mV | Positive | 5 |+| Adaptive zero cross adjustable range | VAZCADJ | -15 | | -3 | mV | Negative | 5 |+| OVP trip threshold | VOVP | 115 | 120 | 125 | % | OVP detect | 5 |+| Output UVP trip threshold | VUVP | 65 | 70 | 75 | % | UVP detect | 5 |+| Output UVP propagation delay time | tUVPDEL | 0.8 | 1 | 1.2 | ms | | 5 |+| Output UVP enable delay time | tUVPEN | 1 | 1.2 | 1.4 | ms | From Enable to UVP workable | 5 |+| V5IN UVLO threshold, wake up | VUVV5IN | 4.2 | 4.38 | 4.5 | V | Wake up | 5 |+| V5IN UVLO threshold, shutdown | VUVV5IN | 3.7 | 3.93 | 4.1 | V | Shutdown | 5 |+ ## CAD (KiCad official) - Symbol: `TPS51218DSCR`
page.json+727@@ -160,6 +160,733 @@ "Package": "WSON-10-EP(3x3)", "Category": "Power Management (PMIC)", "Pins": "11"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "a4e19df548ae6c94",+ "rows": [+ {+ "name": "Input voltage range VBST",+ "symbol": "VBST",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 37,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Input voltage range VBST (note 3, with respect to SW)",+ "symbol": "VBST",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 7,+ "conditions": "with respect to SW terminal",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Input voltage range SW",+ "symbol": "SW",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -5,+ "typ": null,+ "max": 30,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Input voltage range V5IN, EN, TRIP, VFB, RF",+ "symbol": "V5IN, EN, TRIP, VFB, RF",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 7,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Output voltage range DRVH",+ "symbol": "DRVH",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -5,+ "typ": null,+ "max": 37,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Output voltage range DRVH (note 3, with respect to SW)",+ "symbol": "DRVH",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 7,+ "conditions": "with respect to SW terminal",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Output voltage range DRVH pulse",+ "symbol": "DRVH",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -2.5,+ "typ": null,+ "max": 7,+ "conditions": "pulse width < 20 ns",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Output voltage range DRVL",+ "symbol": "DRVL",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.5,+ "typ": null,+ "max": 7,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Output voltage range DRVL pulse",+ "symbol": "DRVL",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -2.5,+ "typ": null,+ "max": 7,+ "conditions": "pulse width < 20 ns",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Output voltage range PGOOD",+ "symbol": "PGOOD",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 7,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Junction temperature range",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature range",+ "symbol": "TSTG",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -55,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage",+ "symbol": "V5IN",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 4.5,+ "typ": null,+ "max": 6.5,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Input voltage range VBST",+ "symbol": "VBST",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -0.1,+ "typ": null,+ "max": 34.5,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Input voltage range SW",+ "symbol": "SW",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -1,+ "typ": null,+ "max": 28,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Input voltage range SW (note 1)",+ "symbol": "SW",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -4,+ "typ": null,+ "max": 28,+ "conditions": "applied for less than 30% of the repetitive period",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Input voltage range VBST (note 2, with respect to SW)",+ "symbol": "VBST",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -0.1,+ "typ": null,+ "max": 6.5,+ "conditions": "with respect to SW terminal",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Input voltage range EN, TRIP, VFB, RF",+ "symbol": "EN, TRIP, VFB, RF",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -0.1,+ "typ": null,+ "max": 6.5,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Output voltage range DRVH",+ "symbol": "DRVH",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -1,+ "typ": null,+ "max": 34.5,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Output voltage range DRVH (note 1)",+ "symbol": "DRVH",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -4,+ "typ": null,+ "max": 34.5,+ "conditions": "applied for less than 30% of the repetitive period",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Output voltage range DRVH (note 2, with respect to SW)",+ "symbol": "DRVH",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -0.1,+ "typ": null,+ "max": 6.5,+ "conditions": "with respect to SW terminal",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Output voltage range DRVL",+ "symbol": "DRVL",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6.5,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Output voltage range PGOOD",+ "symbol": "PGOOD",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -0.1,+ "typ": null,+ "max": 6.5,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Operating free-air temperature",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "V5IN supply current",+ "symbol": "IV5IN",+ "kind": "electrical",+ "unit": "μA",+ "min": null,+ "typ": 320,+ "max": 500,+ "conditions": "TA = 25°C, No Load, VEN = 5 V, VVFB = 0.735 V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "VFB regulation voltage",+ "symbol": "VVFB",+ "kind": "electrical",+ "unit": "V",+ "min": 0.7005,+ "typ": 0.704,+ "max": 0.7075,+ "conditions": "TA = 25°C, skip mode",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "VFB regulation voltage",+ "symbol": "VVFB",+ "kind": "electrical",+ "unit": "V",+ "min": 0.6984,+ "typ": 0.704,+ "max": 0.7096,+ "conditions": "TA = 0°C to 85°C, skip mode",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "VFB regulation voltage",+ "symbol": "VVFB",+ "kind": "electrical",+ "unit": "V",+ "min": 0.697,+ "typ": 0.704,+ "max": 0.711,+ "conditions": "TA = –40°C to 85°C, skip mode",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "VFB input current",+ "symbol": "IVFB",+ "kind": "electrical",+ "unit": "μA",+ "min": null,+ "typ": 0.01,+ "max": 0.2,+ "conditions": "VVFB = 0.735 V, TA = 25°C, skip mode",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Output discharge current from SW pin",+ "symbol": "IDischg",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 5,+ "max": 13,+ "conditions": "VEN = 0 V, VSW = 0.5 V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "DRVH resistance (source)",+ "symbol": "RDRVH",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 1.5,+ "max": 3,+ "conditions": "Source, IDRVH = –50 mA",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "DRVH resistance (sink)",+ "symbol": "RDRVH",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 0.7,+ "max": 1.8,+ "conditions": "Sink, IDRVH = 50 mA",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "DRVL resistance (source)",+ "symbol": "RDRVL",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 1,+ "max": 2.2,+ "conditions": "Source, IDRVL = –50 mA",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "DRVL resistance (sink)",+ "symbol": "RDRVL",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 0.5,+ "max": 1.2,+ "conditions": "Sink, IDRVL = 50 mA",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Dead time DRVH-off to DRVL-on",+ "symbol": "tD",+ "kind": "timing",+ "unit": "ns",+ "min": 7,+ "typ": 17,+ "max": 30,+ "conditions": "DRVH-off to DRVL-on",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Dead time DRVL-off to DRVH-on",+ "symbol": "tD",+ "kind": "timing",+ "unit": "ns",+ "min": 10,+ "typ": 22,+ "max": 35,+ "conditions": "DRVL-off to DRVH-on",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Minimum off-time",+ "symbol": "tOFF(min)",+ "kind": "timing",+ "unit": "ns",+ "min": 150,+ "typ": 260,+ "max": 400,+ "conditions": "TA = 25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "PG threshold, PG in from lower",+ "symbol": "VTHPG",+ "kind": "electrical",+ "unit": "%",+ "min": 92.5,+ "typ": 95,+ "max": 97.5,+ "conditions": "PG in from lower",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "PG threshold, PG in from higher",+ "symbol": "VTHPG",+ "kind": "electrical",+ "unit": "%",+ "min": 107.5,+ "typ": 110,+ "max": 112.5,+ "conditions": "PG in from higher",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "PG delay",+ "symbol": "tPGDEL",+ "kind": "timing",+ "unit": "ms",+ "min": 0.8,+ "typ": 1,+ "max": 1.2,+ "conditions": "Delay for PG in",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Switching frequency",+ "symbol": "fSW",+ "kind": "electrical",+ "unit": "kHz",+ "min": 266,+ "typ": 290,+ "max": 314,+ "conditions": "RRF = 470 kΩ, TA = 25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Switching frequency",+ "symbol": "fSW",+ "kind": "electrical",+ "unit": "kHz",+ "min": 312,+ "typ": 340,+ "max": 368,+ "conditions": "RRF = 200 kΩ, TA = 25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Switching frequency",+ "symbol": "fSW",+ "kind": "electrical",+ "unit": "kHz",+ "min": 349,+ "typ": 380,+ "max": 411,+ "conditions": "RRF = 100 kΩ, TA = 25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Switching frequency",+ "symbol": "fSW",+ "kind": "electrical",+ "unit": "kHz",+ "min": 395,+ "typ": 430,+ "max": 465,+ "conditions": "RRF = 39 kΩ, TA = 25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "TRIP source current",+ "symbol": "ITRIP",+ "kind": "electrical",+ "unit": "μA",+ "min": 9,+ "typ": 10,+ "max": 11,+ "conditions": "VTRIP = 1V, TA = 25°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Current limit threshold setting range VTRIP-GND voltage",+ "symbol": "VTRIP",+ "kind": "electrical",+ "unit": "V",+ "min": 0.2,+ "typ": null,+ "max": 3,+ "conditions": "VTRIP-GND voltage range",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Current limit threshold",+ "symbol": "VOCL",+ "kind": "electrical",+ "unit": "mV",+ "min": 355,+ "typ": 375,+ "max": 395,+ "conditions": "VTRIP = 3.0 V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Current limit threshold",+ "symbol": "VOCL",+ "kind": "electrical",+ "unit": "mV",+ "min": 185,+ "typ": 200,+ "max": 215,+ "conditions": "VTRIP = 1.6 V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Current limit threshold",+ "symbol": "VOCL",+ "kind": "electrical",+ "unit": "mV",+ "min": 17,+ "typ": 25,+ "max": 33,+ "conditions": "VTRIP = 0.2 V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Negative current limit threshold",+ "symbol": "VOCLN",+ "kind": "electrical",+ "unit": "mV",+ "min": -395,+ "typ": -375,+ "max": -355,+ "conditions": "VTRIP = 3.0 V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Negative current limit threshold",+ "symbol": "VOCLN",+ "kind": "electrical",+ "unit": "mV",+ "min": -215,+ "typ": -200,+ "max": -185,+ "conditions": "VTRIP = 1.6 V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Negative current limit threshold",+ "symbol": "VOCLN",+ "kind": "electrical",+ "unit": "mV",+ "min": -33,+ "typ": -25,+ "max": -17,+ "conditions": "VTRIP = 0.2 V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Adaptive zero cross adjustable range",+ "symbol": "VAZCADJ",+ "kind": "electrical",+ "unit": "mV",+ "min": 3,+ "typ": null,+ "max": 15,+ "conditions": "Positive",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Adaptive zero cross adjustable range",+ "symbol": "VAZCADJ",+ "kind": "electrical",+ "unit": "mV",+ "min": -15,+ "typ": null,+ "max": -3,+ "conditions": "Negative",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "OVP trip threshold",+ "symbol": "VOVP",+ "kind": "electrical",+ "unit": "%",+ "min": 115,+ "typ": 120,+ "max": 125,+ "conditions": "OVP detect",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Output UVP trip threshold",+ "symbol": "VUVP",+ "kind": "electrical",+ "unit": "%",+ "min": 65,+ "typ": 70,+ "max": 75,+ "conditions": "UVP detect",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Output UVP propagation delay time",+ "symbol": "tUVPDEL",+ "kind": "timing",+ "unit": "ms",+ "min": 0.8,+ "typ": 1,+ "max": 1.2,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Output UVP enable delay time",+ "symbol": "tUVPEN",+ "kind": "timing",+ "unit": "ms",+ "min": 1,+ "typ": 1.2,+ "max": 1.4,+ "conditions": "From Enable to UVP workable",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "V5IN UVLO threshold, wake up",+ "symbol": "VUVV5IN",+ "kind": "electrical",+ "unit": "V",+ "min": 4.2,+ "typ": 4.38,+ "max": 4.5,+ "conditions": "Wake up",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "V5IN UVLO threshold, shutdown",+ "symbol": "VUVV5IN",+ "kind": "electrical",+ "unit": "V",+ "min": 3.7,+ "typ": 3.93,+ "max": 4.1,+ "conditions": "Shutdown",+ "source_page": 5,+ "source": "datasheet"+ }+ ] } }, "variants": [],