tps51218dscr: specified limits as data (metadata.characteristics, 60 rows from the datasheet)

Ray ·59f2203b0b · ·parent e5cd266
2 files changed +794
README.md+67
@@ -29,6 +29,73 @@ TPS51218DSCR from Texas Instruments, in a WSON-10-EP(3x3). Pinout and pin descri | Category | Power Management (PMIC) | | Pins | 11 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Input voltage range VBST | VBST | -0.3 |  | 37 | V |  | 2 |+| Input voltage range VBST (note 3, with respect to SW) | VBST | -0.3 |  | 7 | V | with respect to SW terminal | 2 |+| Input voltage range SW | SW | -5 |  | 30 | V |  | 2 |+| Input voltage range V5IN, EN, TRIP, VFB, RF | V5IN, EN, TRIP, VFB, RF | -0.3 |  | 7 | V |  | 2 |+| Output voltage range DRVH | DRVH | -5 |  | 37 | V |  | 2 |+| Output voltage range DRVH (note 3, with respect to SW) | DRVH | -0.3 |  | 7 | V | with respect to SW terminal | 2 |+| Output voltage range DRVH pulse | DRVH | -2.5 |  | 7 | V | pulse width < 20 ns | 2 |+| Output voltage range DRVL | DRVL | -0.5 |  | 7 | V |  | 2 |+| Output voltage range DRVL pulse | DRVL | -2.5 |  | 7 | V | pulse width < 20 ns | 2 |+| Output voltage range PGOOD | PGOOD | -0.3 |  | 7 | V |  | 2 |+| Junction temperature range | TJ |  |  | 150 | °C |  | 2 |+| Storage temperature range | TSTG | -55 |  | 150 | °C |  | 2 |+| Supply voltage | V5IN | 4.5 |  | 6.5 | V |  | 3 |+| Input voltage range VBST | VBST | -0.1 |  | 34.5 | V |  | 3 |+| Input voltage range SW | SW | -1 |  | 28 | V |  | 3 |+| Input voltage range SW (note 1) | SW | -4 |  | 28 | V | applied for less than 30% of the repetitive period | 3 |+| Input voltage range VBST (note 2, with respect to SW) | VBST | -0.1 |  | 6.5 | V | with respect to SW terminal | 3 |+| Input voltage range EN, TRIP, VFB, RF | EN, TRIP, VFB, RF | -0.1 |  | 6.5 | V |  | 3 |+| Output voltage range DRVH | DRVH | -1 |  | 34.5 | V |  | 3 |+| Output voltage range DRVH (note 1) | DRVH | -4 |  | 34.5 | V | applied for less than 30% of the repetitive period | 3 |+| Output voltage range DRVH (note 2, with respect to SW) | DRVH | -0.1 |  | 6.5 | V | with respect to SW terminal | 3 |+| Output voltage range DRVL | DRVL | -0.3 |  | 6.5 | V |  | 3 |+| Output voltage range PGOOD | PGOOD | -0.1 |  | 6.5 | V |  | 3 |+| Operating free-air temperature | TA | -40 |  | 85 | °C |  | 3 |+| V5IN supply current | IV5IN |  | 320 | 500 | μA | TA = 25°C, No Load, VEN = 5 V, VVFB = 0.735 V | 4 |+| VFB regulation voltage | VVFB | 0.7005 | 0.704 | 0.7075 | V | TA = 25°C, skip mode | 4 |+| VFB regulation voltage | VVFB | 0.6984 | 0.704 | 0.7096 | V | TA = 0°C to 85°C, skip mode | 4 |+| VFB regulation voltage | VVFB | 0.697 | 0.704 | 0.711 | V | TA = –40°C to 85°C, skip mode | 4 |+| VFB input current | IVFB |  | 0.01 | 0.2 | μA | VVFB = 0.735 V, TA = 25°C, skip mode | 4 |+| Output discharge current from SW pin | IDischg |  | 5 | 13 | mA | VEN = 0 V, VSW = 0.5 V | 4 |+| DRVH resistance (source) | RDRVH |  | 1.5 | 3 | Ω | Source, IDRVH = –50 mA | 4 |+| DRVH resistance (sink) | RDRVH |  | 0.7 | 1.8 | Ω | Sink, IDRVH = 50 mA | 4 |+| DRVL resistance (source) | RDRVL |  | 1 | 2.2 | Ω | Source, IDRVL = –50 mA | 4 |+| DRVL resistance (sink) | RDRVL |  | 0.5 | 1.2 | Ω | Sink, IDRVL = 50 mA | 4 |+| Dead time DRVH-off to DRVL-on | tD | 7 | 17 | 30 | ns | DRVH-off to DRVL-on | 4 |+| Dead time DRVL-off to DRVH-on | tD | 10 | 22 | 35 | ns | DRVL-off to DRVH-on | 4 |+| Minimum off-time | tOFF(min) | 150 | 260 | 400 | ns | TA = 25°C | 4 |+| PG threshold, PG in from lower | VTHPG | 92.5 | 95 | 97.5 | % | PG in from lower | 4 |+| PG threshold, PG in from higher | VTHPG | 107.5 | 110 | 112.5 | % | PG in from higher | 4 |+| PG delay | tPGDEL | 0.8 | 1 | 1.2 | ms | Delay for PG in | 4 |+| Switching frequency | fSW | 266 | 290 | 314 | kHz | RRF = 470 kΩ, TA = 25°C | 4 |+| Switching frequency | fSW | 312 | 340 | 368 | kHz | RRF = 200 kΩ, TA = 25°C | 4 |+| Switching frequency | fSW | 349 | 380 | 411 | kHz | RRF = 100 kΩ, TA = 25°C | 4 |+| Switching frequency | fSW | 395 | 430 | 465 | kHz | RRF = 39 kΩ, TA = 25°C | 4 |+| TRIP source current | ITRIP | 9 | 10 | 11 | μA | VTRIP = 1V, TA = 25°C | 5 |+| Current limit threshold setting range VTRIP-GND voltage | VTRIP | 0.2 |  | 3 | V | VTRIP-GND voltage range | 5 |+| Current limit threshold | VOCL | 355 | 375 | 395 | mV | VTRIP = 3.0 V | 5 |+| Current limit threshold | VOCL | 185 | 200 | 215 | mV | VTRIP = 1.6 V | 5 |+| Current limit threshold | VOCL | 17 | 25 | 33 | mV | VTRIP = 0.2 V | 5 |+| Negative current limit threshold | VOCLN | -395 | -375 | -355 | mV | VTRIP = 3.0 V | 5 |+| Negative current limit threshold | VOCLN | -215 | -200 | -185 | mV | VTRIP = 1.6 V | 5 |+| Negative current limit threshold | VOCLN | -33 | -25 | -17 | mV | VTRIP = 0.2 V | 5 |+| Adaptive zero cross adjustable range | VAZCADJ | 3 |  | 15 | mV | Positive | 5 |+| Adaptive zero cross adjustable range | VAZCADJ | -15 |  | -3 | mV | Negative | 5 |+| OVP trip threshold | VOVP | 115 | 120 | 125 | % | OVP detect | 5 |+| Output UVP trip threshold | VUVP | 65 | 70 | 75 | % | UVP detect | 5 |+| Output UVP propagation delay time | tUVPDEL | 0.8 | 1 | 1.2 | ms |  | 5 |+| Output UVP enable delay time | tUVPEN | 1 | 1.2 | 1.4 | ms | From Enable to UVP workable | 5 |+| V5IN UVLO threshold, wake up | VUVV5IN | 4.2 | 4.38 | 4.5 | V | Wake up | 5 |+| V5IN UVLO threshold, shutdown | VUVV5IN | 3.7 | 3.93 | 4.1 | V | Shutdown | 5 |+ ## CAD (KiCad official)  - Symbol: `TPS51218DSCR`
page.json+727
@@ -160,6 +160,733 @@       "Package": "WSON-10-EP(3x3)",       "Category": "Power Management (PMIC)",       "Pins": "11"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "a4e19df548ae6c94",+      "rows": [+        {+          "name": "Input voltage range VBST",+          "symbol": "VBST",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 37,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range VBST (note 3, with respect to SW)",+          "symbol": "VBST",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 7,+          "conditions": "with respect to SW terminal",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range SW",+          "symbol": "SW",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -5,+          "typ": null,+          "max": 30,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range V5IN, EN, TRIP, VFB, RF",+          "symbol": "V5IN, EN, TRIP, VFB, RF",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 7,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Output voltage range DRVH",+          "symbol": "DRVH",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -5,+          "typ": null,+          "max": 37,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Output voltage range DRVH (note 3, with respect to SW)",+          "symbol": "DRVH",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 7,+          "conditions": "with respect to SW terminal",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Output voltage range DRVH pulse",+          "symbol": "DRVH",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -2.5,+          "typ": null,+          "max": 7,+          "conditions": "pulse width < 20 ns",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Output voltage range DRVL",+          "symbol": "DRVL",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.5,+          "typ": null,+          "max": 7,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Output voltage range DRVL pulse",+          "symbol": "DRVL",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -2.5,+          "typ": null,+          "max": 7,+          "conditions": "pulse width < 20 ns",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Output voltage range PGOOD",+          "symbol": "PGOOD",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 7,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Junction temperature range",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature range",+          "symbol": "TSTG",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Supply voltage",+          "symbol": "V5IN",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 4.5,+          "typ": null,+          "max": 6.5,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range VBST",+          "symbol": "VBST",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 34.5,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range SW",+          "symbol": "SW",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -1,+          "typ": null,+          "max": 28,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range SW (note 1)",+          "symbol": "SW",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -4,+          "typ": null,+          "max": 28,+          "conditions": "applied for less than 30% of the repetitive period",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range VBST (note 2, with respect to SW)",+          "symbol": "VBST",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 6.5,+          "conditions": "with respect to SW terminal",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range EN, TRIP, VFB, RF",+          "symbol": "EN, TRIP, VFB, RF",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 6.5,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output voltage range DRVH",+          "symbol": "DRVH",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -1,+          "typ": null,+          "max": 34.5,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output voltage range DRVH (note 1)",+          "symbol": "DRVH",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -4,+          "typ": null,+          "max": 34.5,+          "conditions": "applied for less than 30% of the repetitive period",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output voltage range DRVH (note 2, with respect to SW)",+          "symbol": "DRVH",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 6.5,+          "conditions": "with respect to SW terminal",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output voltage range DRVL",+          "symbol": "DRVL",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 6.5,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output voltage range PGOOD",+          "symbol": "PGOOD",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 6.5,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Operating free-air temperature",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "V5IN supply current",+          "symbol": "IV5IN",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": 320,+          "max": 500,+          "conditions": "TA = 25°C, No Load, VEN = 5 V, VVFB = 0.735 V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VFB regulation voltage",+          "symbol": "VVFB",+          "kind": "electrical",+          "unit": "V",+          "min": 0.7005,+          "typ": 0.704,+          "max": 0.7075,+          "conditions": "TA = 25°C, skip mode",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VFB regulation voltage",+          "symbol": "VVFB",+          "kind": "electrical",+          "unit": "V",+          "min": 0.6984,+          "typ": 0.704,+          "max": 0.7096,+          "conditions": "TA = 0°C to 85°C, skip mode",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VFB regulation voltage",+          "symbol": "VVFB",+          "kind": "electrical",+          "unit": "V",+          "min": 0.697,+          "typ": 0.704,+          "max": 0.711,+          "conditions": "TA = –40°C to 85°C, skip mode",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VFB input current",+          "symbol": "IVFB",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": 0.01,+          "max": 0.2,+          "conditions": "VVFB = 0.735 V, TA = 25°C, skip mode",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Output discharge current from SW pin",+          "symbol": "IDischg",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 5,+          "max": 13,+          "conditions": "VEN = 0 V, VSW = 0.5 V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "DRVH resistance (source)",+          "symbol": "RDRVH",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 1.5,+          "max": 3,+          "conditions": "Source, IDRVH = –50 mA",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "DRVH resistance (sink)",+          "symbol": "RDRVH",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.7,+          "max": 1.8,+          "conditions": "Sink, IDRVH = 50 mA",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "DRVL resistance (source)",+          "symbol": "RDRVL",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 1,+          "max": 2.2,+          "conditions": "Source, IDRVL = –50 mA",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "DRVL resistance (sink)",+          "symbol": "RDRVL",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.5,+          "max": 1.2,+          "conditions": "Sink, IDRVL = 50 mA",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Dead time DRVH-off to DRVL-on",+          "symbol": "tD",+          "kind": "timing",+          "unit": "ns",+          "min": 7,+          "typ": 17,+          "max": 30,+          "conditions": "DRVH-off to DRVL-on",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Dead time DRVL-off to DRVH-on",+          "symbol": "tD",+          "kind": "timing",+          "unit": "ns",+          "min": 10,+          "typ": 22,+          "max": 35,+          "conditions": "DRVL-off to DRVH-on",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Minimum off-time",+          "symbol": "tOFF(min)",+          "kind": "timing",+          "unit": "ns",+          "min": 150,+          "typ": 260,+          "max": 400,+          "conditions": "TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "PG threshold, PG in from lower",+          "symbol": "VTHPG",+          "kind": "electrical",+          "unit": "%",+          "min": 92.5,+          "typ": 95,+          "max": 97.5,+          "conditions": "PG in from lower",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "PG threshold, PG in from higher",+          "symbol": "VTHPG",+          "kind": "electrical",+          "unit": "%",+          "min": 107.5,+          "typ": 110,+          "max": 112.5,+          "conditions": "PG in from higher",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "PG delay",+          "symbol": "tPGDEL",+          "kind": "timing",+          "unit": "ms",+          "min": 0.8,+          "typ": 1,+          "max": 1.2,+          "conditions": "Delay for PG in",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Switching frequency",+          "symbol": "fSW",+          "kind": "electrical",+          "unit": "kHz",+          "min": 266,+          "typ": 290,+          "max": 314,+          "conditions": "RRF = 470 kΩ, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Switching frequency",+          "symbol": "fSW",+          "kind": "electrical",+          "unit": "kHz",+          "min": 312,+          "typ": 340,+          "max": 368,+          "conditions": "RRF = 200 kΩ, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Switching frequency",+          "symbol": "fSW",+          "kind": "electrical",+          "unit": "kHz",+          "min": 349,+          "typ": 380,+          "max": 411,+          "conditions": "RRF = 100 kΩ, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Switching frequency",+          "symbol": "fSW",+          "kind": "electrical",+          "unit": "kHz",+          "min": 395,+          "typ": 430,+          "max": 465,+          "conditions": "RRF = 39 kΩ, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "TRIP source current",+          "symbol": "ITRIP",+          "kind": "electrical",+          "unit": "μA",+          "min": 9,+          "typ": 10,+          "max": 11,+          "conditions": "VTRIP = 1V, TA = 25°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Current limit threshold setting range VTRIP-GND voltage",+          "symbol": "VTRIP",+          "kind": "electrical",+          "unit": "V",+          "min": 0.2,+          "typ": null,+          "max": 3,+          "conditions": "VTRIP-GND voltage range",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Current limit threshold",+          "symbol": "VOCL",+          "kind": "electrical",+          "unit": "mV",+          "min": 355,+          "typ": 375,+          "max": 395,+          "conditions": "VTRIP = 3.0 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Current limit threshold",+          "symbol": "VOCL",+          "kind": "electrical",+          "unit": "mV",+          "min": 185,+          "typ": 200,+          "max": 215,+          "conditions": "VTRIP = 1.6 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Current limit threshold",+          "symbol": "VOCL",+          "kind": "electrical",+          "unit": "mV",+          "min": 17,+          "typ": 25,+          "max": 33,+          "conditions": "VTRIP = 0.2 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Negative current limit threshold",+          "symbol": "VOCLN",+          "kind": "electrical",+          "unit": "mV",+          "min": -395,+          "typ": -375,+          "max": -355,+          "conditions": "VTRIP = 3.0 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Negative current limit threshold",+          "symbol": "VOCLN",+          "kind": "electrical",+          "unit": "mV",+          "min": -215,+          "typ": -200,+          "max": -185,+          "conditions": "VTRIP = 1.6 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Negative current limit threshold",+          "symbol": "VOCLN",+          "kind": "electrical",+          "unit": "mV",+          "min": -33,+          "typ": -25,+          "max": -17,+          "conditions": "VTRIP = 0.2 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Adaptive zero cross adjustable range",+          "symbol": "VAZCADJ",+          "kind": "electrical",+          "unit": "mV",+          "min": 3,+          "typ": null,+          "max": 15,+          "conditions": "Positive",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Adaptive zero cross adjustable range",+          "symbol": "VAZCADJ",+          "kind": "electrical",+          "unit": "mV",+          "min": -15,+          "typ": null,+          "max": -3,+          "conditions": "Negative",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "OVP trip threshold",+          "symbol": "VOVP",+          "kind": "electrical",+          "unit": "%",+          "min": 115,+          "typ": 120,+          "max": 125,+          "conditions": "OVP detect",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Output UVP trip threshold",+          "symbol": "VUVP",+          "kind": "electrical",+          "unit": "%",+          "min": 65,+          "typ": 70,+          "max": 75,+          "conditions": "UVP detect",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Output UVP propagation delay time",+          "symbol": "tUVPDEL",+          "kind": "timing",+          "unit": "ms",+          "min": 0.8,+          "typ": 1,+          "max": 1.2,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Output UVP enable delay time",+          "symbol": "tUVPEN",+          "kind": "timing",+          "unit": "ms",+          "min": 1,+          "typ": 1.2,+          "max": 1.4,+          "conditions": "From Enable to UVP workable",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "V5IN UVLO threshold, wake up",+          "symbol": "VUVV5IN",+          "kind": "electrical",+          "unit": "V",+          "min": 4.2,+          "typ": 4.38,+          "max": 4.5,+          "conditions": "Wake up",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "V5IN UVLO threshold, shutdown",+          "symbol": "VUVV5IN",+          "kind": "electrical",+          "unit": "V",+          "min": 3.7,+          "typ": 3.93,+          "max": 4.1,+          "conditions": "Shutdown",+          "source_page": 5,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],