← Commit history

Initial commit: component/tps3600d50pw

Ray ·407e8fca9b ·1mo ago
2 files changed +286
README.mdadded+50
@@ -0,0 +1,50 @@+# TPS3600D50PW++**Texas Instruments** · Supervisor And Reset ICs · TSSOP-14++TPS3600D50PW from Texas Instruments, in a TSSOP-14. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model); symbol, footprint, and 3D from KiCad-official CAD.++## Pinout++| Pin | Name | Type | Function |+|---|---|---|---|+| 1 | VOUT | power_out | Supply output that the supervisor monitors; RESET stays active while VOUT remains below the threshold voltage VIT. |+| 2 | VDD | power_in | Input supply voltage; the TPS3600D50 variant has a 5.0 V nominal supply. |+| 3 | GND | power_in | Ground reference for the device. |+| 4 | MSWITCH | input | Manual switch to force the device into battery-backup mode; connect to GND if not used. |+| 5 | CEIN | input | Chip-enable input passed through a series transmission gate to CEOUT; it goes high-impedance while reset is asserted. |+| 6 | BATTON | output | Logic output and external bypass switch driver output. |+| 7 | PFI | input | Power-fail comparator input; connect to GND if not used. |+| 8 | PFO | output | Power-fail comparator output. |+| 9 | BATTOK | output | Battery status output that transitions high-to-low when the backup battery voltage VBAT falls below the negative-going threshold V(BOK); the battery is checked every 200 ms. |+| 10 | CEOUT | output | Chip-enable output; during disable mode an active pullup connects CEOUT to VOUT. |+| 11 | MR | input | Manual reset input. |+| 12 | WDI | input | Watchdog timer input, with the watchdog timing set to an 800 ms time-out per the features list. |+| 13 | RESET | output | Active-low reset output; asserted during power-on until the supply exceeds the threshold, and again on a brownout or power failure. |+| 14 | VBAT | power_in | Backup-battery input, which can exceed VDD per the features list. |++## Key specifications++| Parameter | Value |+|---|---|+| Manufacturer | Texas Instruments |+| Package | TSSOP-14 |+| Category | Power Management (PMIC) |+| Pins | 14 |++## CAD (KiCad official)++- Symbol: `TPS3600D50PW`+- Footprint: `Package_SO:TSSOP-14_4.4x5mm_P0.65mm`+- 3D model: TSSOP-14 (KiCad packages3D, STEP)+- 3D model files: `tps3600d50pw-etched.step` / `tps3600d50pw-etched.glb` carry the MPN laser-etched on the die in a toggleable `Adom.LaserEtch` group (Fusion-ready); `tps3600d50pw.step` / `tps3600d50pw.glb` are the bare package body.++## Provenance++Data extracted from the manufacturer datasheet, not a distributor listing:++- **Datasheet:** [Texas Instruments datasheet](https://www.ti.com/cn/lit/gpn/tps3600) (28 pp, sha256 `22e4caa11ae7d5c6`, retrieved 2026-10-08, tier: lcsc)+- **Extractor:** parts-factory `2.0.0` / `extract_pins 0.3`, primary `claude-haiku-5-5` (text), consensus `claude-sonnet-5-5` (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.+- **CAD:** KiCad official libraries (CC-BY-SA 4.0).++[Datasheet PDF](docs/tps3600d50pw-datasheet.pdf)
page.jsonadded+236
@@ -0,0 +1,236 @@+{+  "slug": "tps3600d50pw",+  "version": "0.1.0",+  "type": "component",+  "description": "Texas Instruments Supervisor And Reset ICs, TSSOP-14. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+  "tags": [+    "component",+    "power management (pmic)",+    "tps3600d50pw",+    "factory-2.0.0",+    "extractor-text"+  ],+  "dependencies": {},+  "hero": {+    "type": "image",+    "path": "docs/hero.png"+  },+  "files": [+    "page.json",+    "README.md",+    "tps3600d50pw.kicad_sym",+    "tps3600d50pw.kicad_mod",+    "tps3600d50pw.glb",+    "tps3600d50pw.step",+    "tps3600d50pw.lbr",+    "docs/hero.png",+    "docs/tps3600d50pw-datasheet.pdf",+    "viewers/symbol.html",+    "viewers/footprint.html",+    "tps3600d50pw-hero.glb",+    "tps3600d50pw-hero.overlay.json"+  ],+  "component": {+    "mpn": "TPS3600D50PW",+    "manufacturer": "Texas Instruments",+    "package": "TSSOP-14",+    "pin_count": 14,+    "category": "Power Management (PMIC)",+    "subcategory": "Supervisor And Reset ICs",+    "datasheet": "https://www.ti.com/cn/lit/gpn/tps3600",+    "parts": {+      "symbol": "tps3600d50pw.kicad_sym",+      "footprint": "tps3600d50pw.kicad_mod",+      "model_3d": "tps3600d50pw-hero.glb",+      "model_3d_plain": "tps3600d50pw.glb",+      "model_3d_step": "tps3600d50pw-etched.step",+      "model_3d_step_plain": "tps3600d50pw.step",+      "lbr": "tps3600d50pw.lbr"+    },+    "distributor_links": {+      "lcsc": "C1355206",+      "digikey": "2156-TPS3600D50PW-ND",+      "mouser": "595-TPS3600D50PW"+    },+    "distributor_check": {+      "checked_at": "2026-10-08T05:03:39Z",+      "source": "Component Ocean /api/assign-pns",+      "digikey": {+        "pn": "2156-TPS3600D50PW-ND",+        "status": "found",+        "lifecycle": "Active"+      },+      "mouser": {+        "pn": "595-TPS3600D50PW",+        "status": "found"+      }+    },+    "pins": [+      {+        "number": "1",+        "name": "VOUT",+        "type": "power_out",+        "description": "Supply output that the supervisor monitors; RESET stays active while VOUT remains below the threshold voltage VIT."+      },+      {+        "number": "2",+        "name": "VDD",+        "type": "power_in",+        "description": "Input supply voltage; the TPS3600D50 variant has a 5.0 V nominal supply."+      },+      {+        "number": "3",+        "name": "GND",+        "type": "power_in",+        "description": "Ground reference for the device."+      },+      {+        "number": "4",+        "name": "MSWITCH",+        "type": "input",+        "description": "Manual switch to force the device into battery-backup mode; connect to GND if not used."+      },+      {+        "number": "5",+        "name": "CEIN",+        "type": "input",+        "description": "Chip-enable input passed through a series transmission gate to CEOUT; it goes high-impedance while reset is asserted."+      },+      {+        "number": "6",+        "name": "BATTON",+        "type": "output",+        "description": "Logic output and external bypass switch driver output."+      },+      {+        "number": "7",+        "name": "PFI",+        "type": "input",+        "description": "Power-fail comparator input; connect to GND if not used."+      },+      {+        "number": "8",+        "name": "PFO",+        "type": "output",+        "description": "Power-fail comparator output."+      },+      {+        "number": "9",+        "name": "BATTOK",+        "type": "output",+        "description": "Battery status output that transitions high-to-low when the backup battery voltage VBAT falls below the negative-going threshold V(BOK); the battery is checked every 200 ms."+      },+      {+        "number": "10",+        "name": "CEOUT",+        "type": "output",+        "description": "Chip-enable output; during disable mode an active pullup connects CEOUT to VOUT."+      },+      {+        "number": "11",+        "name": "MR",+        "type": "input",+        "description": "Manual reset input."+      },+      {+        "number": "12",+        "name": "WDI",+        "type": "input",+        "description": "Watchdog timer input, with the watchdog timing set to an 800 ms time-out per the features list."+      },+      {+        "number": "13",+        "name": "RESET",+        "type": "output",+        "description": "Active-low reset output; asserted during power-on until the supply exceeds the threshold, and again on a brownout or power failure."+      },+      {+        "number": "14",+        "name": "VBAT",+        "type": "power_in",+        "description": "Backup-battery input, which can exceed VDD per the features list."+      }+    ],+    "provenance": {+      "extractor": "extract_pins 0.3",+      "factory_chain": {+        "factory": "2.0.0",+        "extractor": "extract_pins 0.3",+        "primary_model": "claude-haiku-5-5",+        "primary_mode": "text",+        "consensus_model": "claude-sonnet-5-5",+        "consensus": "agreed",+        "guards": "pin_guards 0.1: passed",+        "guard_notes": [+          "extractor flagged: Pin-to-name mapping taken from the Terminal Functions table on page 6 (NAME/NO. columns); the page 1; The datasheet lists VBAT as I and VOUT as O; they are typed here as power_in and power_out because t; The datasheet does not state the active level of MR or the power-fail output PFO polarity beyond the"+        ],+        "pages_sent": 8,+        "cost_usd": 0.0514,+        "at": "2026-10-08T05:03:23"+      },+      "datasheet": {+        "url": "https://www.ti.com/cn/lit/gpn/tps3600",+        "pages": 28,+        "sha256": "22e4caa11ae7d5c6",+        "source_tier": "lcsc"+      },+      "cad": "KiCad official (CC-BY-SA 4.0)",+      "pins": {+        "total": 14,+        "described": 14,+        "cites_pages": true,+        "refuses_to_fabricate": true+      }+    },+    "viewers": {+      "symbol": "viewers/symbol.html",+      "footprint": "viewers/footprint.html"+    },+    "models_3d": [+      {+        "file": "tps3600d50pw.step",+        "role": "plain",+        "up": "Z",+        "units": "mm",+        "origin": "footprint origin = pad-pattern centre",+        "seat": "z = 0",+        "extents_mm": [+          6.4,+          5,+          1+        ],+        "zmin_mm": 0,+        "centre_offset_mm": 0,+        "footprint_binding": "identity",+        "sha256": "3ee5786aae56190997aa793ba3cfc003fd616782770e29719b4562f012982245",+        "checked": "2026-10-08",+        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"+      },+      {+        "file": "tps3600d50pw-etched.step",+        "role": "eda",+        "up": "Z",+        "units": "mm",+        "origin": "footprint origin = pad-pattern centre",+        "seat": "z = 0",+        "extents_mm": [+          6.4,+          5,+          1+        ],+        "zmin_mm": 0,+        "centre_offset_mm": 0,+        "footprint_binding": "identity",+        "sha256": "e0e4897742c3d9d00c0a7446dc9bb77e23cd6fccfa43ca2997134b1bd5b7b49c",+        "checked": "2026-10-08",+        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"+      }+    ]+  },+  "visibility": "public",+  "org": "adom",+  "author": {+    "name": "Ray",+    "email": "[email protected]"+  }+}\ No newline at end of file