← Commit history
package.json+146−4@@ -1,6 +1,6 @@ { "slug": "tps2421-2ddar",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "Texas Instruments Supervisor and Reset ICs, HSOP-8-EP. Datasheet-verified pinout, KiCad symbol/footprint/3D.", "tags": [@@ -24,6 +24,148 @@ "docs/hero.png", "docs/tps2421-2ddar-datasheet.pdf", "viewers/symbol.html",- "viewers/footprint.html"- ]-}+ "viewers/footprint.html",+ "tps2421-2ddar-etched.step",+ "tps2421-2ddar-etched.glb"+ ],+ "component": {+ "mpn": "TPS2421-2DDAR",+ "manufacturer": "Texas Instruments",+ "package": "HSOP-8-EP",+ "pin_count": 8,+ "category": "Supervisor and Reset ICs",+ "datasheet": "https://www.ti.com/lit/ds/symlink/tps2421-2ddar.pdf",+ "parts": {+ "symbol": "tps2421-2ddar.kicad_sym",+ "footprint": "tps2421-2ddar.kicad_mod",+ "model_3d": "tps2421-2ddar-etched.glb",+ "model_3d_plain": "tps2421-2ddar.glb",+ "model_3d_step": "tps2421-2ddar-etched.step",+ "model_3d_step_plain": "tps2421-2ddar.step",+ "lbr": "tps2421-2ddar.lbr"+ },+ "pins": [+ {+ "number": "1",+ "name": "FLT",+ "type": "output",+ "description": "Fault flag, active-low open-drain. Asserted low when the fault timer expires and the internal pass FET is switched off. Max sink 10 mA, pin rated 0-20 V."+ },+ {+ "number": "2",+ "name": "EN",+ "type": "input",+ "description": "Active-low enable. The device is enabled when EN is pulled low. Input range 0-5 V (abs max 6 V)."+ },+ {+ "number": "3",+ "name": "VIN",+ "type": "power_in",+ "description": "Power input and control-supply voltage; drain of the internal pass MOSFET. Recommended operating range 3-20 V (abs max 25 V)."+ },+ {+ "number": "4",+ "name": "GND",+ "type": "power_in",+ "description": "Device ground reference. All voltages are referenced to this pin. Tie the PowerPad to GND for thermal dissipation."+ },+ {+ "number": "5",+ "name": "ISET",+ "type": "bidirectional",+ "description": "Fault-current programming pin. A resistor RRSET to GND (49.9 kΩ to 200 kΩ) sets the fault current threshold; the hard current limit is 150% of the programmed fault current. Pin voltage rated 0-3 V."+ },+ {+ "number": "6",+ "name": "CT",+ "type": "bidirectional",+ "description": "Fault-timer programming pin. A capacitor CCT to GND (minimum 0.1 nF) sets the duration the fault current may flow before the FET is switched off. Pin voltage rated 0-3 V."+ },+ {+ "number": "7",+ "name": "VOUT",+ "type": "power_out",+ "description": "Source of the internal pass MOSFET; switched output to the load. Continuous output current 0-6 A (abs max 9 A); rated 0-20 V (abs max 25 V)."+ },+ {+ "number": "8",+ "name": "PG",+ "type": "output",+ "description": "Power-Good flag, active-low open-drain. Asserted low when VOUT is within 300 mV of VIN. Max sink 10 mA, pin rated 0-20 V."+ }+ ],+ "provenance": {+ "rebuilt": "component block rebuilt 2026-10-05 from this page's own README pinout table and .kicad_sym (pins cross-checked), no re-extraction",+ "cad": "KiCad official (CC-BY-SA 4.0)",+ "cad_basis": {+ "from": [+ "README CAD section (factory cad_wording)",+ ".kicad_mod model path agrees"+ ],+ "missing": []+ }+ },+ "viewers": {+ "symbol": "viewers/symbol.html",+ "footprint": "viewers/footprint.html"+ },+ "distributor_links": {+ "lcsc": "C128602",+ "digikey": "296-24239-2-ND",+ "mouser": "595-TPS2421-2DDAR"+ },+ "distributor_check": {+ "checked_at": "2026-10-05T19:23:02Z",+ "source": "Component Ocean /api/assign-pns + lcsc_map",+ "digikey": {+ "pn": "296-24239-2-ND",+ "status": "found"+ },+ "mouser": {+ "pn": "595-TPS2421-2DDAR",+ "status": "found"+ }+ },+ "models_3d": [+ {+ "file": "tps2421-2ddar.step",+ "role": "plain",+ "up": "Z",+ "units": "mm",+ "origin": "footprint origin = pad-pattern centre",+ "seat": "z = 0",+ "extents_mm": [+ 6,+ 4.9,+ 1.75+ ],+ "zmin_mm": 0,+ "centre_offset_mm": 0,+ "footprint_binding": "identity",+ "sha256": "aa1f86df473b51d6fffa82d4ff5a0ca030b07835b04d46a38a7b8cb0f27e418e",+ "checked": "2026-10-07",+ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"+ },+ {+ "file": "tps2421-2ddar-etched.step",+ "role": "eda",+ "up": "Z",+ "units": "mm",+ "origin": "footprint origin = pad-pattern centre",+ "seat": "z = 0",+ "extents_mm": [+ 6,+ 4.9,+ 1.75+ ],+ "zmin_mm": 0,+ "centre_offset_mm": 0,+ "footprint_binding": "identity",+ "sha256": "56981a905a3e4162c0494b933295c5ba235ce19b05a2706944dddf9b93d4bf6d",+ "checked": "2026-10-07",+ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"+ }+ ]+ },+ "visibility": "public"+}
page.json+7−7@@ -1,6 +1,6 @@ { "slug": "tps2421-2ddar",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "Texas Instruments Supervisor and Reset ICs, HSOP-8-EP. Datasheet-verified pinout, KiCad symbol/footprint/3D.", "tags": [@@ -25,11 +25,10 @@ "docs/tps2421-2ddar-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html",- "tps2421-2ddar-etched.step"+ "tps2421-2ddar-etched.step",+ "tps2421-2ddar-etched.glb" ],- "visibility": {- "public": true- },+ "visibility": "public", "author": { "name": "Ray" },@@ -171,5 +170,6 @@ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)" } ]- }-}+ },+ "org": "adom"+}