component
TPS2363PFBR
Public Made by Adomby adom
Texas Instruments Supervisor And Reset ICs, TQFP-48(7x7). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.
main
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465
{
"schema_version": 1,
"type": "component",
"slug": "tps2363pfbr",
"title": "TPS2363PFBR",
"brief": "Texas Instruments Supervisor And Reset ICs, TQFP-48(7x7). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",
"version": "0.1.0",
"license": "CC-BY-SA-4.0",
"tags": [
"component",
"power management (pmic)",
"tps2363pfbr",
"factory-2.0.0",
"extractor-text"
],
"component": {
"mpn": "TPS2363PFBR",
"manufacturer": "Texas Instruments",
"package": "TQFP-48(7x7)",
"pin_count": 48,
"category": "Power Management (PMIC)",
"subcategory": "Supervisor And Reset ICs",
"datasheet": "https://www.ti.com/cn/lit/gpn/tps2363",
"parts": {
"symbol": "tps2363pfbr.kicad_sym",
"footprint": "tps2363pfbr.kicad_mod",
"model_3d": "tps2363pfbr-hero.glb",
"model_3d_plain": "tps2363pfbr.glb",
"model_3d_step": "tps2363pfbr-etched.step",
"model_3d_step_plain": "tps2363pfbr.step",
"lbr": "tps2363pfbr.lbr"
},
"distributor_links": {
"lcsc": "C2678216",
"digikey": "296-50070-2-ND",
"mouser": "595-TPS2363PFBR"
},
"distributor_check": {
"checked_at": "2026-10-11T09:18:55Z",
"source": "Component Ocean /api/assign-pns",
"digikey": {
"pn": "296-50070-2-ND",
"status": "found",
"lifecycle": "Active"
},
"mouser": {
"pn": "595-TPS2363PFBR",
"status": "found"
}
},
"pins": [
{
"number": "1",
"name": "FAULTA",
"type": "output",
"description": "Active-low open-drain fault output for slot A (filtered) that must be pulled up to AUXINA with a 100-kΩ resistor."
},
{
"number": "2",
"name": "FILTERA",
"type": "input",
"description": "An external capacitor from this pin to ground sets the time a main or AUX fault may persist before slot A main power is turned off."
},
{
"number": "3",
"name": "G12A",
"type": "output",
"description": "Gate drive for the 12-V P-channel FET of slot A; a capacitor from this pin to OUT12A sets the slew rate to limit inrush current."
},
{
"number": "4",
"name": "GPIA1",
"type": "input",
"description": "Filtered general-purpose input for a mechanical switch, read through the SMBus status register, with an internal 100-kΩ pull-down; connect to ground if unused."
},
{
"number": "5",
"name": "SH12A",
"type": "power_in",
"description": "12-V supply input and high side of the slot A 12-V sense resistor, requiring a 0.1 µF bypass capacitor to ground and Kelvin-aware layout."
},
{
"number": "6",
"name": "PGOODA",
"type": "output",
"description": "Active-low open-drain power-good output for slot A that must be pulled up to AUXINA with a 100-kΩ resistor."
},
{
"number": "7",
"name": "GPIA2",
"type": "input",
"description": "Filtered general-purpose input for a mechanical switch, read through the SMBus status register; available only on the TPS2363 and left unconnected if not used."
},
{
"number": "8",
"name": "SL12A",
"type": "input",
"description": "Low side of the slot A 12-V sense resistor; an over-current condition exists when the voltage across the sense resistor exceeds the current-limit threshold, and a Kelvin connection is required."
},
{
"number": "9",
"name": "FORCEONA",
"type": "input",
"description": "Active-low input that forces slot A on even during a fault for diagnostics, disableable via SMBus FORCEON INHIB bits, and overridden by thermal shutdown."
},
{
"number": "10",
"name": "OUT12A",
"type": "bidirectional",
"description": "12-V channel output used to monitor slot A voltage for power good, with a 1.2-kΩ bleed-down active when main power is off and power-off readable below 100 mV via SMBus."
},
{
"number": "11",
"name": "AUXINA",
"type": "power_in",
"description": "3.3-V auxiliary supply input for PCI Express, SMBus and internal logic that requires a 0.1 µF bypass capacitor and must be tied to 3.3 V if no AUX supply is used."
},
{
"number": "12",
"name": "SH33A",
"type": "power_in",
"description": "3.3-V supply input and high side of the slot A 3.3-V sense resistor, requiring a 0.1 µF bypass capacitor to ground."
},
{
"number": "13",
"name": "SL33A",
"type": "input",
"description": "Low side of the slot A 3.3-V sense resistor; an over-current condition exists when the voltage across the sense resistor exceeds the current-limit threshold, and a Kelvin connection is required."
},
{
"number": "14",
"name": "G33A",
"type": "output",
"description": "Gate drive for the 3.3-V N-channel FET of slot A; a capacitor from this pin to ground sets the slew rate to limit inrush current."
},
{
"number": "15",
"name": "VAUXA",
"type": "power_out",
"description": "VAUX output to slot A that is current limited to 400 mA by default, or 800 mA when the AUXHIA pin is pulled up."
},
{
"number": "16",
"name": "OUT33A",
"type": "bidirectional",
"description": "3.3-V channel output used to monitor slot A voltage for power good, with a 1.2-kΩ bleed-down active when main power is off and power-off readable below 100 mV via SMBus."
},
{
"number": "17",
"name": "GND",
"type": "power_in",
"description": "Ground reference pin."
},
{
"number": "18",
"name": "AUXHIA",
"type": "input",
"description": "Selects 800 mA VAUX current for slot A when pulled up to AUXINA through a 10-kΩ maximum resistor; NC or ground selects the default 400 mA, and an internal 40-kΩ pull-down is present."
},
{
"number": "19",
"name": "AUXHIB",
"type": "input",
"description": "Selects 800 mA VAUX current for slot B when pulled up to AUXINB through a 10-kΩ maximum resistor; NC or ground selects the default 400 mA, and an internal 40-kΩ pull-down is present."
},
{
"number": "20",
"name": "RFILTER",
"type": "input",
"description": "A 110-kΩ resistor from this pin to ground improves fault timer accuracy for both slots."
},
{
"number": "21",
"name": "OUT33B",
"type": "bidirectional",
"description": "3.3-V channel output used to monitor slot B voltage for power good, with a 1.2-kΩ bleed-down active when main power is off and power-off readable below 100 mV via SMBus."
},
{
"number": "22",
"name": "VAUXB",
"type": "power_out",
"description": "VAUX output to slot B that is current limited to 400 mA by default, or 800 mA when the AUXHIB pin is pulled up."
},
{
"number": "23",
"name": "G33B",
"type": "output",
"description": "Gate drive for the 3.3-V N-channel FET of slot B; a capacitor from this pin to ground sets the slew rate to limit inrush current."
},
{
"number": "24",
"name": "SL33B",
"type": "input",
"description": "Low side of the slot B 3.3-V sense resistor; an over-current condition exists when the voltage across the sense resistor exceeds the current-limit threshold, and a Kelvin connection is required."
},
{
"number": "25",
"name": "SH33B",
"type": "power_in",
"description": "3.3-V supply input and high side of the slot B 3.3-V sense resistor, requiring a 0.1 µF bypass capacitor to ground."
},
{
"number": "26",
"name": "AUXINB",
"type": "power_in",
"description": "3.3-V auxiliary supply input for PCI Express, SMBus and internal logic that requires a 0.1 µF bypass capacitor and must be tied to 3.3 V if no AUX supply is used."
},
{
"number": "27",
"name": "OUT12B",
"type": "bidirectional",
"description": "12-V channel output used to monitor slot B voltage for power good, with a 1.2-kΩ bleed-down active when main power is off and power-off readable below 100 mV via SMBus."
},
{
"number": "28",
"name": "FORCEONB",
"type": "input",
"description": "Active-low input that forces slot B on even during a fault for diagnostics, disableable via SMBus FORCEON INHIB bits, and overridden by thermal shutdown."
},
{
"number": "29",
"name": "SL12B",
"type": "input",
"description": "Low side of the slot B 12-V sense resistor; an over-current condition exists when the voltage across the sense resistor exceeds the current-limit threshold, and a Kelvin connection is required."
},
{
"number": "30",
"name": "GPIB2",
"type": "input",
"description": "Filtered general-purpose input for a mechanical switch, read through the SMBus status register; available only on the TPS2363 and left unconnected if not used."
},
{
"number": "31",
"name": "PGOODB",
"type": "output",
"description": "Active-low open-drain power-good output for slot B that must be pulled up to AUXINB with a 100-kΩ resistor."
},
{
"number": "32",
"name": "SH12B",
"type": "power_in",
"description": "12-V supply input and high side of the slot B 12-V sense resistor, requiring a 0.1 µF bypass capacitor to ground."
},
{
"number": "33",
"name": "GND",
"type": "power_in",
"description": "Ground reference pin."
},
{
"number": "34",
"name": "G12B",
"type": "output",
"description": "Gate drive for the 12-V P-channel FET of slot B; a capacitor from this pin to OUT12B sets the slew rate to limit inrush current."
},
{
"number": "35",
"name": "FILTERB",
"type": "input",
"description": "An external capacitor from this pin to ground sets the time a main or AUX fault may persist before slot B main power is turned off."
},
{
"number": "36",
"name": "FAULTB",
"type": "output",
"description": "Active-low open-drain fault output for slot B (filtered) that must be pulled up to AUXINB with a 100-kΩ resistor."
},
{
"number": "37",
"name": "INT",
"type": "output",
"description": "Active-low open-drain interrupt output asserted on a fault, which must be pulled up to 3.3 V or AUXIN through an external 10-kΩ resistor at the end of the bus."
},
{
"number": "38",
"name": "GPIB1",
"type": "input",
"description": "Filtered general-purpose input for a mechanical switch, read through the SMBus status register, with an internal 100-kΩ pull-down; connect to ground if unused."
},
{
"number": "39",
"name": "A2",
"type": "input",
"description": "SMBus address select input internally pulled up to 3.3 V or AUXIN through 40 kΩ, read at initialization only, and tied to ground for a zero."
},
{
"number": "40",
"name": "A1",
"type": "input",
"description": "SMBus address select input internally pulled up to 3.3 V or AUXIN through 40 kΩ, read at initialization only, and tied to ground for a zero."
},
{
"number": "41",
"name": "A0",
"type": "input",
"description": "SMBus address select input internally pulled up to 3.3 V or AUXIN through 40 kΩ, read at initialization only, and tied to ground for a zero."
},
{
"number": "42",
"name": "AUXENB",
"type": "input",
"description": "Active-high, level-sensitive enable for the slot B VAUX output; taking it low clears a VAUX fault, and it should be connected to ground when using the SMBus interface."
},
{
"number": "43",
"name": "ONB",
"type": "input",
"description": "Active-high enable for the slot B main 12-V and 3.3-V outputs; taking it low clears a main-supply fault, and it should be connected to ground when using the SMBus interface."
},
{
"number": "44",
"name": "ONA",
"type": "input",
"description": "Active-high enable for the slot A main 12-V and 3.3-V outputs; taking it low clears a main-supply fault, and it should be connected to ground when using the SMBus interface."
},
{
"number": "45",
"name": "AUXENA",
"type": "input",
"description": "Active-high, level-sensitive enable for the slot A VAUX output; taking it low clears a VAUX fault, and it should be connected to ground when using the SMBus interface."
},
{
"number": "46",
"name": "GND",
"type": "power_in",
"description": "Ground reference pin."
},
{
"number": "47",
"name": "SCL",
"type": "input",
"description": "SMBus clock input that must be pulled up to 3.3 V or AUXIN through an external 10-kΩ resistor at the end of the bus."
},
{
"number": "48",
"name": "SDA",
"type": "bidirectional",
"description": "SMBus data input/output and address input that must be pulled up to 3.3 V or AUXIN through an external 10-kΩ resistor at the end of the bus."
}
],
"provenance": {
"extractor": "extract_pins 0.3",
"factory_chain": {
"factory": "2.0.0",
"extractor": "extract_pins 0.3",
"primary_model": "claude-haiku-5-5",
"primary_mode": "text",
"consensus_model": "claude-sonnet-5-5",
"consensus": "agreed",
"guards": "pin_guards 0.1: passed",
"guard_notes": [
"extractor flagged: Pin numbers for the A and B channel signals are paired in the terminal table (for example FAULTA/B =; The datasheet lists the supply, sense, and AUX pins as type I. I assigned power_in or power_out base; FAULT, PGOOD and INT are open-drain outputs. The allowed type set has no open-drain class, so they a",
"19/48 pins cited to the wrong page (name found elsewhere): ['4:GPIA1@p7', '7:GPIA2@p7', '21:OUT33B@p8', '22:VAUXB@p7']"
],
"pages_sent": 16,
"cost_usd": 0.127,
"at": "2026-10-11T09:18:30"
},
"datasheet": {
"url": "https://www.ti.com/cn/lit/gpn/tps2363",
"pages": 47,
"sha256": "0022f32de279ab1d",
"source_tier": "lcsc"
},
"cad": "KiCad official (CC-BY-SA 4.0)",
"pins": {
"total": 48,
"described": 48,
"cites_pages": true,
"refuses_to_fabricate": true
}
},
"viewers": {
"symbol": "viewers/symbol.html",
"footprint": "viewers/footprint.html"
},
"models_3d": [
{
"file": "tps2363pfbr.step",
"role": "plain",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
9,
9,
1.1
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "14ca7676e4932e92f0eca0c6d56ce3018cd28a2531204a70ab7bbacb3eeb3cf5",
"checked": "2026-10-11",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
},
{
"file": "tps2363pfbr-etched.step",
"role": "eda",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
9,
9,
1.1
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "e3234212f408fc7018cf3852ab6c1940281257142ef7e647e06acf6172b74954",
"checked": "2026-10-11",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
}
]
},
"metadata": {
"specs": {
"Manufacturer": "Texas Instruments",
"Package": "TQFP-48(7x7)",
"Category": "Power Management (PMIC)",
"Pins": "48"
}
},
"variants": [],
"sections": [
"hero",
"viewers",
"readme",
"breadcrumbs",
"info"
],
"discovery_triggers": [
"tps2363pfbr"
],
"discovery_pitch": "TPS2363PFBR (Texas Instruments) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
"author": {
"name": "Ray",
"email": "[email protected]"
},
"dependencies": {},
"hero": {
"type": "image",
"path": "docs/hero.png"
},
"files": [
"page.json",
"README.md",
"tps2363pfbr.kicad_sym",
"tps2363pfbr.kicad_mod",
"tps2363pfbr.glb",
"tps2363pfbr.step",
"tps2363pfbr.lbr",
"docs/hero.png",
"docs/tps2363pfbr-datasheet.pdf",
"viewers/symbol.html",
"viewers/footprint.html",
"tps2363pfbr-hero.glb",
"tps2363pfbr-hero.overlay.json"
],
"visibility": {
"public": true
}
}