main
Ray tmp100na: component.models_3d pose record per STEP (Z-up, seated z=0, pad-centre origin, identity binding) ccd8093 19h ago
{
  "schema_version": 1,
  "type": "component",
  "slug": "tmp100na",
  "title": "TMP100NA",
  "brief": "Texas Instruments Temperature and Humidity Sensor, SOT-23-6. Pinout extracted from the datasheet, KiCad symbol/footprint/3D.",
  "version": "0.1.0",
  "license": "CC-BY-SA-4.0",
  "tags": [
    "component",
    "sensor",
    "tmp100na"
  ],
  "component": {
    "mpn": "TMP100NA",
    "manufacturer": "Texas Instruments",
    "package": "SOT-23-6",
    "pin_count": 6,
    "category": "Sensor",
    "subcategory": "Temperature and Humidity Sensor",
    "datasheet": "https://www.ti.com/lit/ds/symlink/tmp100.pdf",
    "parts": {
      "symbol": "tmp100na.kicad_sym",
      "footprint": "tmp100na.kicad_mod",
      "model_3d": "tmp100na-etched.glb",
      "model_3d_plain": "tmp100na.glb",
      "model_3d_step": "tmp100na-etched.step",
      "model_3d_step_plain": "tmp100na.step",
      "lbr": "tmp100na.lbr"
    },
    "distributor_links": {},
    "pins": [
      {
        "number": "1",
        "name": "SCL",
        "type": "input",
        "description": "Serial clock input for the I2C/SMBus/Two-Wire interface. Open-drain; requires an external pullup resistor to V+. Supports fast mode (400 kHz) and high-speed mode (up to 2 MHz)."
      },
      {
        "number": "2",
        "name": "GND",
        "type": "power_in",
        "description": "Ground reference. Also serves as the primary thermal path since it is directly connected to the metal lead frame."
      },
      {
        "number": "3",
        "name": "ADD1",
        "type": "input",
        "description": "Address select pin 1. Connect to GND, V+, or leave floating to set one of three logic levels used to encode the I2C slave address. Sampled at power-up and latched."
      },
      {
        "number": "4",
        "name": "V+",
        "type": "power_in",
        "description": "Positive supply voltage input, 2.7 V to 5.5 V. Absolute maximum 7.5 V."
      },
      {
        "number": "5",
        "name": "ADD0",
        "type": "input",
        "description": "Address select pin 0. Connect to GND, V+, or leave floating to set one of three logic levels used to encode the I2C slave address. Sampled at power-up and latched."
      },
      {
        "number": "6",
        "name": "SDA",
        "type": "bidirectional",
        "description": "Serial data line for the I2C/SMBus/Two-Wire interface. Open-drain output; requires an external pullup resistor to V+."
      }
    ],
    "provenance": {
      "extractor": "ds2sf",
      "datasheet": {
        "url": "https://www.ti.com/lit/ds/symlink/tmp100.pdf",
        "pages": 31,
        "sha256": "4099b7e562d93331",
        "source_tier": "mfr"
      },
      "cad": "KiCad official (CC-BY-SA 4.0)",
      "pins": {
        "total": 6,
        "described": 6,
        "cites_pages": true,
        "refuses_to_fabricate": true
      }
    },
    "viewers": {
      "symbol": "viewers/symbol.html",
      "footprint": "viewers/footprint.html"
    },
    "models_3d": [
      {
        "file": "tmp100na.step",
        "role": "plain",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          2.8,
          2.9,
          1.55
        ],
        "zmin_mm": 0.0,
        "centre_offset_mm": 0.0,
        "footprint_binding": "identity",
        "sha256": "c9fe686b4d1b56927a41fa84a9bc1efb61d8a45a123a3db43bcaa05c2891d635",
        "checked": "2026-10-07",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      },
      {
        "file": "tmp100na-etched.step",
        "role": "eda",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          2.8,
          2.9,
          1.55
        ],
        "zmin_mm": 0.0,
        "centre_offset_mm": 0.0,
        "footprint_binding": "identity",
        "sha256": "c9c57afd9cf44be674ab1e11756eb6416225a94b90f03b2400f47e07178a63b0",
        "checked": "2026-10-07",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      }
    ]
  },
  "metadata": {
    "specs": {
      "Manufacturer": "Texas Instruments",
      "Package": "SOT-23-6",
      "Category": "Sensor",
      "Pins": "6"
    }
  },
  "sections": [
    "hero",
    "viewers",
    "readme",
    "breadcrumbs",
    "info"
  ],
  "discovery_triggers": [
    "tmp100na"
  ],
  "discovery_pitch": "TMP100NA (Texas Instruments) component page with datasheet-verified CAD.",
  "author": {
    "name": "Ray",
    "email": "[email protected]"
  },
  "dependencies": {},
  "hero": {
    "type": "image",
    "path": "docs/hero.png"
  },
  "files": [
    "page.json",
    "README.md",
    "tmp100na.kicad_sym",
    "tmp100na.kicad_mod",
    "tmp100na.glb",
    "tmp100na.step",
    "tmp100na.lbr",
    "docs/hero.png",
    "docs/tmp100na-datasheet.pdf",
    "viewers/symbol.html",
    "viewers/footprint.html",
    "tmp100na-etched.step"
  ],
  "visibility": {
    "public": true
  },
  "variants": [
    {
      "mpn": "TMP100NA",
      "kind": "packaging"
    },
    {
      "mpn": "TMP100NAAIDBVR",
      "kind": "packaging"
    },
    {
      "mpn": "TMP100NAAIDBVT",
      "kind": "packaging"
    },
    {
      "mpn": "TMP100NAQDBVR",
      "kind": "packaging"
    }
  ],
  "updated_at": "2026-09-25T11:04:13.401Z"
}