main
John Lauer Add symbol, footprint, Fusion and Altium libraries, viewers, provenance, README ab389b2 6h ago
[
 {"number":"1","name":"IN+","type":"passive","group":"Primary side","description":"Input current positive pin: one end of the 0.7 mOhm internal conductor (SBOSA24D p.4, Table 5-1; RIN p.8). Current flowing from IN+ to IN- gives a positive output change. This pin is on the primary (high-voltage) side of the isolation barrier."},
 {"number":"2","name":"IN-","type":"passive","group":"Primary side","description":"Input current negative pin: the other end of the internal conductor (p.4, Table 5-1). Primary (high-voltage) side of the isolation barrier."},
 {"number":"8","name":"VS","type":"power_in","group":"Supply","description":"Power supply, 3.0 V to 5.5 V (p.4; p.5 recommended operating conditions). Decouple to GND with 0.1 uF placed close to the pin (p.35)."},
 {"number":"3","name":"GND","type":"power_in","group":"Supply","description":"Ground of the isolated low-voltage side (p.4, Table 5-1)."},
 {"number":"6","name":"VOUT","type":"output","group":"Analog output","description":"Output voltage: VOUT = VREF + S x IIN, linear from 100 mV to VS - 100 mV (p.4; p.24 Eq. 18 to 21). B1A: S = 25 mV/A, zero-current output 1.65 V."},
 {"number":"5","name":"VREF","type":"output","group":"Analog output","description":"Zero-current output voltage reference (1.65 V on BxA parts), for ratiometric or differential measurement of VOUT. Leave floating if not used (p.4; p.9)."},
 {"number":"9","name":"VOC","type":"input","group":"Overcurrent","description":"Overcurrent threshold input: VOC = S x IOC / 2.5, 0.3 V to VS, 120 kOhm input impedance. Connect to VS if not used (p.4; p.9; p.25)."},
 {"number":"7","name":"OC","type":"open_collector","group":"Overcurrent","description":"Overcurrent output, open-drain, active low. Needs a pull-up. Connect to GND if not used (p.4, Table 5-1)."},
 {"number":"4","name":"ALERT","type":"open_collector","group":"Overcurrent","description":"Sensor diagnostics output: open-drain, active low, 8 kHz PWM whose duty cycle reports thermal and sensor alerts (p.4; p.9; p.28). Connect to GND if not used."},
 {"number":"10","name":"NC","type":"no_connect","group":"Reserved","description":"Reserved. The datasheet allows it to be connected to GND or left floating (p.4, Table 5-1). Typed no-connect; tying it to GND is permitted by TI but will need an ERC waiver."}
]