123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540541542543544545546547548549550551552553554555556557558559560561562563564565566567568569570571572573574575576577578579580581582583584585586587588589590591592593594595596597598599600601602603604605606607608609610611612613614615616617618619620621622623624625626627628629630631632633634635636637638639640641642643644645646647648649650651652653654655656657658659660661662663664665666667668669670671672673674675676677678679680681682683684685686687688689690691692693694695696697698699700701702703704705706707708709710711712713714715716717718719720721722723724725726727728729730731732733734735736737738739740741742743744745746747748749750751752753754755756757758759760761762763764765766767768769770771772773774775776777778779780781782783784785786787788789790791792793794795796797798799800801802803804805806807808809810811812813814815816817818819820821822823824825826827828829830831832833834835836837838839840841842843844845846847848849850851852853854855856857858859860861862863864865866867868869870871872873874875876877878879880881882883884885886887888889890891892893894895896897898899900901902903904905906907908909910911912913914915916917918919920921922923924925926927928929930931932933934935936937938939940941942943944945946947
{
  "slug": "tls850f2tav50atma1",
  "version": "0.1.1",
  "type": "component",
  "description": "Infineon Technologies Linear Voltage Regulators (LDO), TO-263-7. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",
  "tags": [
    "component",
    "power supply chip",
    "tls850f2tav50atma1",
    "factory-2.0.0",
    "extractor-text"
  ],
  "dependencies": {},
  "hero": {
    "type": "image",
    "path": "docs/hero.png"
  },
  "files": [
    "page.json",
    "README.md",
    "tls850f2tav50atma1.kicad_sym",
    "tls850f2tav50atma1.kicad_mod",
    "tls850f2tav50atma1.glb",
    "tls850f2tav50atma1.step",
    "tls850f2tav50atma1.lbr",
    "docs/hero.png",
    "docs/tls850f2tav50atma1-datasheet.pdf",
    "viewers/symbol.html",
    "viewers/footprint.html",
    "tls850f2tav50atma1-hero.glb",
    "tls850f2tav50atma1-hero.overlay.json",
    "tls850f2tav50atma1-etched.glb",
    "tls850f2tav50atma1-etched.step"
  ],
  "component": {
    "mpn": "TLS850F2TAV50ATMA1",
    "manufacturer": "Infineon Technologies",
    "package": "TO-263-7",
    "pin_count": 8,
    "category": "Power Supply Chip",
    "subcategory": "Linear Voltage Regulators (LDO)",
    "datasheet": "https://datasheet.lcsc.com/datasheet/pdf/77188ca588f166b2fa4eb2191650b982.pdf",
    "parts": {
      "symbol": "tls850f2tav50atma1.kicad_sym",
      "footprint": "tls850f2tav50atma1.kicad_mod",
      "model_3d": "tls850f2tav50atma1-hero.glb",
      "model_3d_plain": "tls850f2tav50atma1.glb",
      "model_3d_step": "tls850f2tav50atma1-etched.step",
      "model_3d_step_plain": "tls850f2tav50atma1.step",
      "lbr": "tls850f2tav50atma1.lbr"
    },
    "distributor_links": {
      "lcsc": "C3745764",
      "digikey": "448-TLS850F2TAV50ATMA1TR-ND",
      "mouser": "726-TLS850F2TAV50ATM"
    },
    "distributor_check": {
      "checked_at": "2026-11-02T17:26:39Z",
      "source": "Component Ocean /api/assign-pns",
      "digikey": {
        "pn": "448-TLS850F2TAV50ATMA1TR-ND",
        "status": "found"
      },
      "mouser": {
        "pn": "726-TLS850F2TAV50ATM",
        "status": "found"
      }
    },
    "pins": [
      {
        "number": "1",
        "name": "I",
        "type": "power_in",
        "description": "Regulator input; place a small ceramic capacitor (e.g. 100 nF) to GND close to the IC terminals to compensate line influences."
      },
      {
        "number": "2",
        "name": "EN",
        "type": "input",
        "description": "Enable input with integrated pull-down resistor: a high level enables the IC and a low level disables it."
      },
      {
        "number": "3",
        "name": "RO/WO",
        "type": "output",
        "description": "Open-collector reset/watchdog output with integrated pull-up resistor to Q; leave open if the reset and watchdog functions are not needed."
      },
      {
        "number": "4",
        "name": "GND",
        "type": "power_in",
        "description": "Ground reference pin; connect the heat slug to GND as well."
      },
      {
        "number": "5",
        "name": "RADJ",
        "type": "input",
        "description": "Reset threshold adjustment: connect to GND for the standard value, or to an external voltage divider to adjust the reset threshold (adjustable down to 2.50 V)."
      },
      {
        "number": "6",
        "name": "WI",
        "type": "input",
        "description": "Watchdog trigger input with integrated pull-down resistor, used to serve the watchdog for microcontroller monitoring."
      },
      {
        "number": "7",
        "name": "Q",
        "type": "power_out",
        "description": "Regulated 5 V output; connect output capacitor CQ to GND close to the IC terminals, respecting the capacitance and ESR values in the Functional range on page 7."
      },
      {
        "number": "8",
        "name": "EP",
        "type": "passive",
        "description": "Exposed pad (from the footprint; not named in the datasheet pin table)."
      }
    ],
    "provenance": {
      "extractor": "extract_pins 0.3",
      "factory_chain": {
        "factory": "2.0.0",
        "extractor": "extract_pins 0.3",
        "primary_model": "claude-haiku-5-5",
        "primary_mode": "text",
        "consensus_model": "claude-sonnet-5-5",
        "consensus": "agreed",
        "guards": "pin_guards 0.1: passed",
        "guard_notes": [
          "extractor flagged: The heat slug is listed in the Pin definitions table (page 5) without a printed pin number, so it is"
        ],
        "pages_sent": 7,
        "cost_usd": 0.0133,
        "at": "2026-11-02T17:26:28"
      },
      "datasheet": {
        "url": "https://datasheet.lcsc.com/datasheet/pdf/77188ca588f166b2fa4eb2191650b982.pdf",
        "pages": 35,
        "sha256": "a3b92c0e0eb12d70",
        "source_tier": "mfr"
      },
      "cad": "KiCad official (CC-BY-SA 4.0)",
      "pins": {
        "total": 8,
        "described": 8,
        "cites_pages": true,
        "refuses_to_fabricate": true
      }
    },
    "viewers": {
      "symbol": "viewers/symbol.html",
      "footprint": "viewers/footprint.html"
    },
    "models_3d": [
      {
        "file": "tls850f2tav50atma1.step",
        "role": "plain",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          15.0,
          10.0,
          4.42
        ],
        "zmin_mm": 0.0,
        "centre_offset_mm": 0.0,
        "footprint_binding": "identity",
        "sha256": "34b8121b216e7b6490402befe573a69b06919acafd33d6e8da88bd238574da52",
        "checked": "2026-11-02",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      },
      {
        "file": "tls850f2tav50atma1-etched.step",
        "role": "eda",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          15.0,
          10.0,
          4.42
        ],
        "zmin_mm": 0.0,
        "centre_offset_mm": 0.0,
        "footprint_binding": "identity",
        "sha256": "9181a89c4345c6f521b5720b0c304fac293d6631f9948ab71e1bcd2515f44cdd",
        "checked": "2026-11-02",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      }
    ]
  },
  "title": "TLS850F2TAV50ATMA1",
  "brief": "Infineon Technologies Linear Voltage Regulators (LDO), TO-263-7. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",
  "metadata": {
    "specs": {
      "Manufacturer": "Infineon Technologies",
      "Package": "TO-263-7",
      "Category": "Power Supply Chip",
      "Pins": "8"
    },
    "appearance": {
      "housing": {
        "quote": "The watchdog function monitors a microcontroller, including time base failures. In case of a missing falling edge within a certain pulse repetition time, the watchdog output “RO/WO” is set to “low”.",
        "page": 24,
        "doc": "ds.pdf",
        "material": "pet"
      },
      "version": 1,
      "datasheet_sha256": "a3b92c0e0eb12d707eacdccc91b915451e3b9d1f062e6fb5da857cd1513e96bd"
    },
    "characteristics": {
      "version": 1,
      "source": "datasheet",
      "datasheet_sha256": "a3b92c0e0eb12d707eacdccc91b915451e3b9d1f062e6fb5da857cd1513e96bd",
      "rows": [
        {
          "name": "Input, Enable voltage",
          "symbol": "VI, VEN",
          "kind": "absolute_maximum",
          "unit": "V",
          "min": -0.3,
          "typ": null,
          "max": 45,
          "conditions": "",
          "source_page": 6,
          "source": "datasheet"
        },
        {
          "name": "Output Q, Reset/watchdog output voltage",
          "symbol": "VQ, VRO/WO",
          "kind": "absolute_maximum",
          "unit": "V",
          "min": -0.3,
          "typ": null,
          "max": 7,
          "conditions": "",
          "source_page": 6,
          "source": "datasheet"
        },
        {
          "name": "Watchdog input, Reset threshold adjustment voltage",
          "symbol": "VWI, VRADJ",
          "kind": "absolute_maximum",
          "unit": "V",
          "min": -0.3,
          "typ": null,
          "max": 7,
          "conditions": "",
          "source_page": 6,
          "source": "datasheet"
        },
        {
          "name": "Junction temperature",
          "symbol": "Tj",
          "kind": "absolute_maximum",
          "unit": "°C",
          "min": -40,
          "typ": null,
          "max": 150,
          "conditions": "",
          "source_page": 6,
          "source": "datasheet"
        },
        {
          "name": "Storage temperature",
          "symbol": "Tstg",
          "kind": "absolute_maximum",
          "unit": "°C",
          "min": -55,
          "typ": null,
          "max": 150,
          "conditions": "",
          "source_page": 6,
          "source": "datasheet"
        },
        {
          "name": "ESD susceptibility to GND HBM",
          "symbol": "VESD",
          "kind": "absolute_maximum",
          "unit": "kV",
          "min": -2,
          "typ": null,
          "max": 2,
          "conditions": "HBM",
          "source_page": 6,
          "source": "datasheet"
        },
        {
          "name": "ESD susceptibility to GND CDM",
          "symbol": "VESD",
          "kind": "absolute_maximum",
          "unit": "V",
          "min": -500,
          "typ": null,
          "max": 500,
          "conditions": "CDM",
          "source_page": 6,
          "source": "datasheet"
        },
        {
          "name": "ESD susceptibility pin 1, 7 (corner pins) to GND",
          "symbol": "VESD1,7",
          "kind": "absolute_maximum",
          "unit": "V",
          "min": -750,
          "typ": null,
          "max": 750,
          "conditions": "CDM",
          "source_page": 6,
          "source": "datasheet"
        },
        {
          "name": "Input voltage range",
          "symbol": "VI",
          "kind": "recommended_operating",
          "unit": "V",
          "min": null,
          "typ": null,
          "max": 40,
          "conditions": "",
          "source_page": 7,
          "source": "datasheet"
        },
        {
          "name": "Extended input voltage range",
          "symbol": "VI,ext",
          "kind": "recommended_operating",
          "unit": "V",
          "min": 3,
          "typ": null,
          "max": 40,
          "conditions": "",
          "source_page": 7,
          "source": "datasheet"
        },
        {
          "name": "Enable voltage range",
          "symbol": "VEN",
          "kind": "recommended_operating",
          "unit": "V",
          "min": 0,
          "typ": null,
          "max": 40,
          "conditions": "",
          "source_page": 7,
          "source": "datasheet"
        },
        {
          "name": "Output capacitor requirement for stability",
          "symbol": "CQ",
          "kind": "recommended_operating",
          "unit": "µF",
          "min": 1,
          "typ": null,
          "max": null,
          "conditions": "",
          "source_page": 7,
          "source": "datasheet"
        },
        {
          "name": "Output capacitor ESR",
          "symbol": "ESR(CQ)",
          "kind": "recommended_operating",
          "unit": "Ω",
          "min": null,
          "typ": null,
          "max": 100,
          "conditions": "",
          "source_page": 7,
          "source": "datasheet"
        },
        {
          "name": "Junction temperature (functional range)",
          "symbol": "Tj",
          "kind": "recommended_operating",
          "unit": "°C",
          "min": -40,
          "typ": null,
          "max": 150,
          "conditions": "",
          "source_page": 7,
          "source": "datasheet"
        },
        {
          "name": "Output voltage precision",
          "symbol": "VQ",
          "kind": "electrical",
          "unit": "V",
          "min": 4.9,
          "typ": 5,
          "max": 5.1,
          "conditions": "0.05 mA < IQ < 500 mA; 5.95 V < VI < 28 V",
          "source_page": 11,
          "source": "datasheet"
        },
        {
          "name": "Output voltage start-up slew rate",
          "symbol": "dVQ/dt",
          "kind": "timing",
          "unit": "V/ms",
          "min": 3,
          "typ": 7.5,
          "max": 18,
          "conditions": "VI > 18 V/ms; CQ = 1 µF; 0.5 V < VQ < 4.5 V",
          "source_page": 11,
          "source": "datasheet"
        },
        {
          "name": "Output current limitation",
          "symbol": "IQ,max",
          "kind": "electrical",
          "unit": "mA",
          "min": 501,
          "typ": 650,
          "max": 1100,
          "conditions": "0 V < VQ < 4.8 V",
          "source_page": 11,
          "source": "datasheet"
        },
        {
          "name": "Load regulation steady-state",
          "symbol": "ΔVQ,load",
          "kind": "electrical",
          "unit": "mV",
          "min": -20,
          "typ": -1.5,
          "max": 5,
          "conditions": "IQ = 0.05 mA to 500 mA; VI = 6 V",
          "source_page": 11,
          "source": "datasheet"
        },
        {
          "name": "Line regulation steady-state",
          "symbol": "ΔVQ,line",
          "kind": "electrical",
          "unit": "mV",
          "min": -25,
          "typ": 0,
          "max": 25,
          "conditions": "VI = 8 V to 32 V; IQ = 5 mA",
          "source_page": 11,
          "source": "datasheet"
        },
        {
          "name": "Dropout voltage Vdr = VI - VQ",
          "symbol": "Vdr",
          "kind": "electrical",
          "unit": "mV",
          "min": null,
          "typ": 175,
          "max": 425,
          "conditions": "IQ = 250 mA",
          "source_page": 11,
          "source": "datasheet"
        },
        {
          "name": "Dropout voltage Vdr = VI - VQ",
          "symbol": "Vdr",
          "kind": "electrical",
          "unit": "mV",
          "min": null,
          "typ": 70,
          "max": 170,
          "conditions": "IQ = 100 mA",
          "source_page": 11,
          "source": "datasheet"
        },
        {
          "name": "Overtemperature shutdown threshold",
          "symbol": "Tj,sd",
          "kind": "electrical",
          "unit": "°C",
          "min": 151,
          "typ": null,
          "max": 200,
          "conditions": "Tj increasing",
          "source_page": 11,
          "source": "datasheet"
        },
        {
          "name": "Current consumption",
          "symbol": "Iq,off",
          "kind": "electrical",
          "unit": "µA",
          "min": null,
          "typ": 1.3,
          "max": 5,
          "conditions": "VEN = 0 V; Tj < 105 °C",
          "source_page": 15,
          "source": "datasheet"
        },
        {
          "name": "Current consumption",
          "symbol": "Iq,off",
          "kind": "electrical",
          "unit": "µA",
          "min": null,
          "typ": null,
          "max": 8,
          "conditions": "VEN = 0.4 V; Tj < 125 °C",
          "source_page": 15,
          "source": "datasheet"
        },
        {
          "name": "Current consumption",
          "symbol": "Iq",
          "kind": "electrical",
          "unit": "µA",
          "min": null,
          "typ": 40,
          "max": 52,
          "conditions": "IQ = 0.05 mA; Tj = 25 °C; Watchdog enabled",
          "source_page": 15,
          "source": "datasheet"
        },
        {
          "name": "Current consumption",
          "symbol": "Iq",
          "kind": "electrical",
          "unit": "µA",
          "min": null,
          "typ": 62,
          "max": 77,
          "conditions": "IQ = 0.05 mA; Tj < 125 °C; Watchdog enabled",
          "source_page": 15,
          "source": "datasheet"
        },
        {
          "name": "Current consumption",
          "symbol": "Iq",
          "kind": "electrical",
          "unit": "µA",
          "min": null,
          "typ": 62,
          "max": 82,
          "conditions": "IQ = 500 mA; Tj < 125 °C; Watchdog enabled",
          "source_page": 15,
          "source": "datasheet"
        },
        {
          "name": "High level input voltage",
          "symbol": "VEN,H",
          "kind": "electrical",
          "unit": "V",
          "min": 2,
          "typ": null,
          "max": null,
          "conditions": "VQ settled",
          "source_page": 17,
          "source": "datasheet"
        },
        {
          "name": "Low level input voltage",
          "symbol": "VEN,L",
          "kind": "electrical",
          "unit": "V",
          "min": null,
          "typ": null,
          "max": 0.8,
          "conditions": "VQ ≤ 0.1 V",
          "source_page": 17,
          "source": "datasheet"
        },
        {
          "name": "Enable threshold hysteresis",
          "symbol": "VEN,Hy",
          "kind": "electrical",
          "unit": "mV",
          "min": 100,
          "typ": null,
          "max": null,
          "conditions": "",
          "source_page": 17,
          "source": "datasheet"
        },
        {
          "name": "High level input current",
          "symbol": "IEN,H",
          "kind": "electrical",
          "unit": "µA",
          "min": null,
          "typ": null,
          "max": 3.5,
          "conditions": "VEN = 3.3 V",
          "source_page": 17,
          "source": "datasheet"
        },
        {
          "name": "High level input current",
          "symbol": "IEN,H",
          "kind": "electrical",
          "unit": "µA",
          "min": null,
          "typ": null,
          "max": 22,
          "conditions": "VEN ≤ 18 V",
          "source_page": 17,
          "source": "datasheet"
        },
        {
          "name": "Enable internal pull-down resistor",
          "symbol": "REN",
          "kind": "electrical",
          "unit": "MΩ",
          "min": 0.95,
          "typ": 1.5,
          "max": 2.6,
          "conditions": "",
          "source_page": 17,
          "source": "datasheet"
        },
        {
          "name": "Output undervoltage reset upper switching threshold",
          "symbol": "VRT,high",
          "kind": "electrical",
          "unit": "V",
          "min": 4.6,
          "typ": 4.7,
          "max": 4.8,
          "conditions": "VQ increasing",
          "source_page": 22,
          "source": "datasheet"
        },
        {
          "name": "Output undervoltage reset lower switching threshold - default",
          "symbol": "VRT,low",
          "kind": "electrical",
          "unit": "V",
          "min": 4.5,
          "typ": 4.6,
          "max": 4.7,
          "conditions": "VQ decreasing; RADJ = GND",
          "source_page": 22,
          "source": "datasheet"
        },
        {
          "name": "Output undervoltage reset switching hysteresis",
          "symbol": "VRT,hy",
          "kind": "electrical",
          "unit": "mV",
          "min": 60,
          "typ": 100,
          "max": null,
          "conditions": "RADJ connected to GND",
          "source_page": 22,
          "source": "datasheet"
        },
        {
          "name": "Output undervoltage reset headroom VQ - VRT",
          "symbol": "VRH",
          "kind": "electrical",
          "unit": "mV",
          "min": 200,
          "typ": 400,
          "max": null,
          "conditions": "RADJ = GND",
          "source_page": 22,
          "source": "datasheet"
        },
        {
          "name": "Reset adjustment switching threshold",
          "symbol": "VRADJ,th",
          "kind": "electrical",
          "unit": "V",
          "min": 1.15,
          "typ": 1.2,
          "max": 1.25,
          "conditions": "",
          "source_page": 22,
          "source": "datasheet"
        },
        {
          "name": "Reset threshold adjustment range",
          "symbol": "VRT,range",
          "kind": "electrical",
          "unit": "V",
          "min": 2.5,
          "typ": null,
          "max": 4.4,
          "conditions": "for VQ,nom = 5V",
          "source_page": 22,
          "source": "datasheet"
        },
        {
          "name": "Reset output / watchdog output low voltage",
          "symbol": "VRO/WO,low",
          "kind": "electrical",
          "unit": "V",
          "min": null,
          "typ": 0.2,
          "max": 0.4,
          "conditions": "1 V ≤ VQ ≤ VRT; RRO/WO ≥ 5.1 kΩ",
          "source_page": 22,
          "source": "datasheet"
        },
        {
          "name": "Reset output / watchdog output internal pull-up resistor",
          "symbol": "RRO/WO,int",
          "kind": "electrical",
          "unit": "kΩ",
          "min": 10,
          "typ": 20,
          "max": 36,
          "conditions": "internally connected to Q",
          "source_page": 22,
          "source": "datasheet"
        },
        {
          "name": "Reset output / watchdog output external pull-up resistor to VQ",
          "symbol": "RRO/WO,ext",
          "kind": "electrical",
          "unit": "kΩ",
          "min": 5.1,
          "typ": null,
          "max": null,
          "conditions": "1V ≤ VQ ≤ VRT; VRO/WO ≤ 0.4 V",
          "source_page": 22,
          "source": "datasheet"
        },
        {
          "name": "Reset delay time",
          "symbol": "trd",
          "kind": "timing",
          "unit": "ms",
          "min": 13.2,
          "typ": 16.5,
          "max": 19.8,
          "conditions": "Fixed Timing",
          "source_page": 22,
          "source": "datasheet"
        },
        {
          "name": "Internal reset reaction time",
          "symbol": "trr,int",
          "kind": "timing",
          "unit": "µs",
          "min": null,
          "typ": 10,
          "max": 33,
          "conditions": "for VQ,nom =5V",
          "source_page": 22,
          "source": "datasheet"
        },
        {
          "name": "Watchdog ignore time",
          "symbol": "tWI,i",
          "kind": "timing",
          "unit": "ms",
          "min": 12.8,
          "typ": 16,
          "max": 19.2,
          "conditions": "",
          "source_page": 26,
          "source": "datasheet"
        },
        {
          "name": "Watchdog trigger time",
          "symbol": "tWI,tr",
          "kind": "timing",
          "unit": "ms",
          "min": 76.8,
          "typ": 96,
          "max": 115.2,
          "conditions": "",
          "source_page": 26,
          "source": "datasheet"
        },
        {
          "name": "Watchdog output low time",
          "symbol": "tWO,low",
          "kind": "timing",
          "unit": "ms",
          "min": 6.4,
          "typ": 8,
          "max": 9.6,
          "conditions": "",
          "source_page": 26,
          "source": "datasheet"
        },
        {
          "name": "Watchdog input low signal valid",
          "symbol": "VWI,low",
          "kind": "electrical",
          "unit": "V",
          "min": null,
          "typ": null,
          "max": 0.8,
          "conditions": "",
          "source_page": 26,
          "source": "datasheet"
        },
        {
          "name": "Watchdog input high signal valid",
          "symbol": "VWI,high",
          "kind": "electrical",
          "unit": "V",
          "min": 2,
          "typ": null,
          "max": null,
          "conditions": "",
          "source_page": 26,
          "source": "datasheet"
        },
        {
          "name": "Watchdog input high signal pulse length",
          "symbol": "tWI,ph",
          "kind": "timing",
          "unit": "µs",
          "min": 1,
          "typ": null,
          "max": null,
          "conditions": "VWI ≥ VWI,high",
          "source_page": 26,
          "source": "datasheet"
        },
        {
          "name": "Watchdog input low signal pulse length",
          "symbol": "tWI,pl",
          "kind": "timing",
          "unit": "µs",
          "min": 1,
          "typ": null,
          "max": null,
          "conditions": "VWI ≤ VWI,low",
          "source_page": 26,
          "source": "datasheet"
        },
        {
          "name": "Watchdog input signal slew rate",
          "symbol": "dVWI/dt",
          "kind": "timing",
          "unit": "V/µs",
          "min": 1,
          "typ": null,
          "max": null,
          "conditions": "VWI,low < VWI < VWI,high",
          "source_page": 26,
          "source": "datasheet"
        },
        {
          "name": "High level input current",
          "symbol": "IWI,H",
          "kind": "electrical",
          "unit": "µA",
          "min": null,
          "typ": null,
          "max": 3.5,
          "conditions": "VWI = 3.3 V",
          "source_page": 26,
          "source": "datasheet"
        },
        {
          "name": "Watchdog input internal pull-down resistor",
          "symbol": "RWI",
          "kind": "electrical",
          "unit": "MΩ",
          "min": 0.9,
          "typ": 1.5,
          "max": 2.6,
          "conditions": "",
          "source_page": 26,
          "source": "datasheet"
        },
        {
          "name": "Watchdog disable threshold WI signal value",
          "symbol": "VWI,dis",
          "kind": "electrical",
          "unit": "V",
          "min": 1.15,
          "typ": null,
          "max": 1.4,
          "conditions": "for VQ,nom = 5 V: VI > 5.95 V; signal must be applied for > tW,filter,max to deactivate and activate the watchdog",
          "source_page": 26,
          "source": "datasheet"
        },
        {
          "name": "Watchdog minimum filter time state transition by WI",
          "symbol": "tWI,filter,min",
          "kind": "timing",
          "unit": "µs",
          "min": 100,
          "typ": null,
          "max": null,
          "conditions": "",
          "source_page": 26,
          "source": "datasheet"
        },
        {
          "name": "Watchdog maximum filter time state transition by WI",
          "symbol": "tWI,filter,max",
          "kind": "timing",
          "unit": "µs",
          "min": null,
          "typ": null,
          "max": 500,
          "conditions": "",
          "source_page": 26,
          "source": "datasheet"
        },
        {
          "name": "Junction to ambient (2s2p board)",
          "symbol": "RthJA",
          "kind": "thermal",
          "unit": "K/W",
          "min": null,
          "typ": 21,
          "max": null,
          "conditions": "2s2p board",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Junction to ambient (1s0p, 300 mm2 heatsink area)",
          "symbol": "RthJA",
          "kind": "thermal",
          "unit": "K/W",
          "min": null,
          "typ": 42,
          "max": null,
          "conditions": "1s0p board, 300 mm2 heatsink area on PCB",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Junction to ambient (1s0p, 600 mm2 heatsink area)",
          "symbol": "RthJA",
          "kind": "thermal",
          "unit": "K/W",
          "min": null,
          "typ": 34,
          "max": null,
          "conditions": "1s0p board, 600 mm2 heatsink area on PCB",
          "source_page": 8,
          "source": "datasheet"
        }
      ]
    }
  },
  "discovery_triggers": [
    "tls850f2tav50atma1"
  ],
  "discovery_pitch": "TLS850F2TAV50ATMA1 (Infineon Technologies) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
  "visibility": "public"
}