← Commit history
page.json+7−4@@ -44,7 +44,7 @@ "number": "3", "name": "TXD", "type": "input",- "description": "UART transmit data input from host MCU (5 V logic for TD521D485H-A). VIH >= 0.7*VCC, VIL <= 0.3*VCC. Internal 10 k\u03a9 pull-up to VCC; TXD drive current 2 mA. Data driven onto the RS-485 A/B bus with automatic direction control."+ "description": "UART transmit data input from host MCU (5 V logic for TD521D485H-A). VIH >= 0.7*VCC, VIL <= 0.3*VCC. Internal 10 kΩ pull-up to VCC; TXD drive current 2 mA. Data driven onto the RS-485 A/B bus with automatic direction control." }, { "number": "4",@@ -62,13 +62,13 @@ "number": "8", "name": "B", "type": "bidirectional",- "description": "RS-485 differential bus line B (inverting). Referenced to RGND on the isolated side. Internal pull-down and 47 k\u03a9 bias resistor; receiver input impedance >= 48 k\u03a9 over -7 V <= VCM <= +12 V. Integrated ESD protection."+ "description": "RS-485 differential bus line B (inverting). Referenced to RGND on the isolated side. Internal pull-down and 47 kΩ bias resistor; receiver input impedance >= 48 kΩ over -7 V <= VCM <= +12 V. Integrated ESD protection." }, { "number": "9", "name": "A", "type": "bidirectional",- "description": "RS-485 differential bus line A (non-inverting). Referenced to RGND on the isolated side. Differential output |VOD| >= 1.5 V into 54 \u03a9 load; IOD >= 28 mA. Integrated ESD protection."+ "description": "RS-485 differential bus line A (non-inverting). Referenced to RGND on the isolated side. Differential output |VOD| >= 1.5 V into 54 Ω load; IOD >= 28 mA. Integrated ESD protection." }, { "number": "10",@@ -148,5 +148,8 @@ "docs/td521d485h-a-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }