page.json+9−6
@@ -32,7 +32,7 @@         "number": "1",         "name": "TXD",         "type": "input",-        "description": "CAN transmit data input from the host MCU/controller. LOW drives a dominant bus state, HIGH allows recessive. Logic thresholds are 0.7\u00d7VIO / 0.3\u00d7VIO on the V-suffix variant. Includes a dominant time-out (DTO) protection for data rates down to 10 kbps."+        "description": "CAN transmit data input from the host MCU/controller. LOW drives a dominant bus state, HIGH allows recessive. Logic thresholds are 0.7×VIO / 0.3×VIO on the V-suffix variant. Includes a dominant time-out (DTO) protection for data rates down to 10 kbps."       },       {         "number": "2",@@ -50,7 +50,7 @@         "number": "4",         "name": "RXD",         "type": "output",-        "description": "CAN receive data output to the host MCU/controller. LOW indicates a dominant bus state, HIGH indicates recessive. Output is driven to VIO on 'V' suffix devices (this variant). IO drive limit \u00b12 mA over recommended conditions (absolute max \u00b18 mA)."+        "description": "CAN receive data output to the host MCU/controller. LOW indicates a dominant bus state, HIGH indicates recessive. Output is driven to VIO on 'V' suffix devices (this variant). IO drive limit ±2 mA over recommended conditions (absolute max ±8 mA)."       },       {         "number": "5",@@ -62,19 +62,19 @@         "number": "6",         "name": "CANL",         "type": "bidirectional",-        "description": "Low-side CAN bus I/O line. Forms the differential pair with CANH. Fault protected to \u00b158 V (non-H variants such as this V-suffix part) with respect to GND. \u00b130 V receiver common-mode input range; \u00b115 kV IEC ESD."+        "description": "Low-side CAN bus I/O line. Forms the differential pair with CANH. Fault protected to ±58 V (non-H variants such as this V-suffix part) with respect to GND. ±30 V receiver common-mode input range; ±15 kV IEC ESD."       },       {         "number": "7",         "name": "CANH",         "type": "bidirectional",-        "description": "High-side CAN bus I/O line. Forms the differential pair with CANL. Fault protected to \u00b158 V (non-H variants) with respect to GND. \u00b130 V receiver common-mode input range; \u00b115 kV IEC ESD."+        "description": "High-side CAN bus I/O line. Forms the differential pair with CANL. Fault protected to ±58 V (non-H variants) with respect to GND. ±30 V receiver common-mode input range; ±15 kV IEC ESD."       },       {         "number": "8",         "name": "STB",         "type": "input",-        "description": "Standby mode control input (active HIGH). Drive LOW for normal mode; drive HIGH to place the transceiver into low-power standby with remote wake (WUP) monitoring on the bus. Logic thresholds are 0.7\u00d7VIO / 0.3\u00d7VIO on this V-suffix variant."+        "description": "Standby mode control input (active HIGH). Drive LOW for normal mode; drive HIGH to place the transceiver into low-power standby with remote wake (WUP) monitoring on the bus. Logic thresholds are 0.7×VIO / 0.3×VIO on this V-suffix variant."       }     ],     "provenance": {@@ -138,5 +138,8 @@     "docs/tcan1042vdrq1-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file