← Commit history

std16nf06t4: specified limits as data (metadata.characteristics, 36 rows from the datasheet)

Ray ·b0bc79649f ·24d ago ·parent 19ad0a1
2 files changed +482
README.md+43
@@ -21,6 +21,49 @@ STD16NF06T4 from STMicroelectronics, in a TO-252. Pinout and pin descriptions ex | Category | Transistors/Thyristors | | Pins | 3 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Drain-source voltage | VDS |  |  | 60 | V | VGS = 0V | 2 |+| Drain-gate voltage | VDGR |  |  | 60 | V | RGS = 20 kΩ | 2 |+| Gate-source voltage | VGS | -20 |  | 20 | V |  | 2 |+| Drain current (continuous) | ID |  |  | 16 | A | TC = 25°C | 2 |+| Drain current (continuous) | ID |  |  | 11 | A | TC = 100°C | 2 |+| Drain current (pulsed) | IDM |  |  | 64 | A |  | 2 |+| Total dissipation | PTOT |  |  | 40 | W | TC = 25°C | 2 |+| Peak diode recovery voltage slope | dv/dt |  |  | 10.5 | V/ns |  | 2 |+| Single pulse avalanche energy | EAS |  |  | 178 | mJ |  | 2 |+| Operating junction and storage temperature range | TJ, Tstg | -55 |  | 175 | °C |  | 2 |+| Maximum lead temperature for soldering | Tl |  |  | 275 | °C |  | 2 |+| Thermal resistance junction-case | RthJC |  |  | 3.75 | °C/W |  | 2 |+| Thermal resistance junction-ambient | RthJA |  |  | 100 | °C/W |  | 2 |+| Drain-source breakdown voltage | V(BR)DSS | 60 |  |  | V | ID = 250µA VGS = 0 | 3 |+| Zero gate voltage drain current | IDSS |  |  | 1 | µA | VDS = Max Rating | 3 |+| Zero gate voltage drain current | IDSS |  |  | 10 | µA | VDS = Max Rating TC=125°C | 3 |+| Gate body leakage current | IGSS | -100 |  | 100 | µA | VDS = 0 VGS = ±20V | 3 |+| Gate threshold voltage | VGS(th) | 2 |  |  | V | VDS = VGS ID = 250µA | 3 |+| Static drain-source on resistance | RDS(on) |  | 0.06 | 0.07 | Ω | VGS = 10V ID = 8A | 3 |+| Forward transconductance | gfs | 6 |  |  | S | VDS = 25V ID = 8A | 3 |+| Input capacitance | Ciss |  | 400 |  | pF | VDS = 15V, f = 1MHz, VGS = 0 | 3 |+| Output capacitance | Coss |  | 103 |  | pF | VDS = 15V, f = 1MHz, VGS = 0 | 3 |+| Reverse transfer capacitance | Crss |  | 41.5 |  | pF | VDS = 15V, f = 1MHz, VGS = 0 | 3 |+| Total gate charge | Qg |  | 14.1 |  | nC | VDD = 30 ID = 16A VGS = 10V | 3 |+| Gate-source charge | Qgs |  | 2.8 |  | nC | VDD = 30 ID = 16A VGS = 10V | 3 |+| Gate-drain charge | Qgd |  | 5.4 |  | nC | VDD = 30 ID = 16A VGS = 10V | 3 |+| Turn-on delay time | td(on) |  | 4 |  | ns | VDD = 30V, ID = 8A, RG = 4.7Ω, VGS = 10V | 3 |+| Rise time | tr |  | 15 |  | ns | VDD = 30V, ID = 8A, RG = 4.7Ω, VGS = 10V | 3 |+| Turn-off delay time | td(off) |  | 16 |  | ns | VDD = 30V, ID = 8A, RG = 4.7Ω, VGS = 10V | 3 |+| Fall time | tf |  | 5.5 |  | ns | VDD = 30V, ID = 8A, RG = 4.7Ω, VGS = 10V | 3 |+| Source-drain current | ISD |  |  | 16 | A |  | 4 |+| Source-drain current (pulsed) | ISDM |  |  | 64 | A |  | 4 |+| Forward on voltage | VSD |  |  | 1.5 | V | ISD = 8A VGS = 0 | 4 |+| Reverse recovery time | trr |  | 49 |  | ns | ISD = 16A, di/dt = 100A/µs, VDD = 20V, TJ = 150°C | 4 |+| Reverse recovery charge | Qrr |  | 78 |  | µC | ISD = 16A, di/dt = 100A/µs, VDD = 20V, TJ = 150°C | 4 |+| Reverse recovery current | IRRM |  | 3.2 |  | A | ISD = 16A, di/dt = 100A/µs, VDD = 20V, TJ = 150°C | 4 |+ ## CAD (KiCad official)  - Symbol: `STD16NF06T4`
page.json+439
@@ -136,6 +136,445 @@       "Package": "TO-252",       "Category": "Transistors/Thyristors",       "Pins": "3"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "907c53843105aea3",+      "rows": [+        {+          "name": "Drain-source voltage",+          "symbol": "VDS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 60,+          "conditions": "VGS = 0V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain-gate voltage",+          "symbol": "VDGR",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 60,+          "conditions": "RGS = 20 kΩ",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate-source voltage",+          "symbol": "VGS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain current (continuous)",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 16,+          "conditions": "TC = 25°C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain current (continuous)",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 11,+          "conditions": "TC = 100°C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain current (pulsed)",+          "symbol": "IDM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 64,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Total dissipation",+          "symbol": "PTOT",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "TC = 25°C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Peak diode recovery voltage slope",+          "symbol": "dv/dt",+          "kind": "absolute_maximum",+          "unit": "V/ns",+          "min": null,+          "typ": null,+          "max": 10.5,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Single pulse avalanche energy",+          "symbol": "EAS",+          "kind": "absolute_maximum",+          "unit": "mJ",+          "min": null,+          "typ": null,+          "max": 178,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Operating junction and storage temperature range",+          "symbol": "TJ, Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 175,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum lead temperature for soldering",+          "symbol": "Tl",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 275,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Thermal resistance junction-case",+          "symbol": "RthJC",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 3.75,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Thermal resistance junction-ambient",+          "symbol": "RthJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 100,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain-source breakdown voltage",+          "symbol": "V(BR)DSS",+          "kind": "electrical",+          "unit": "V",+          "min": 60,+          "typ": null,+          "max": null,+          "conditions": "ID = 250µA VGS = 0",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Zero gate voltage drain current",+          "symbol": "IDSS",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "VDS = Max Rating",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Zero gate voltage drain current",+          "symbol": "IDSS",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "VDS = Max Rating TC=125°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Gate body leakage current",+          "symbol": "IGSS",+          "kind": "electrical",+          "unit": "µA",+          "min": -100,+          "typ": null,+          "max": 100,+          "conditions": "VDS = 0 VGS = ±20V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Gate threshold voltage",+          "symbol": "VGS(th)",+          "kind": "electrical",+          "unit": "V",+          "min": 2,+          "typ": null,+          "max": null,+          "conditions": "VDS = VGS ID = 250µA",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Static drain-source on resistance",+          "symbol": "RDS(on)",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.06,+          "max": 0.07,+          "conditions": "VGS = 10V ID = 8A",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Forward transconductance",+          "symbol": "gfs",+          "kind": "electrical",+          "unit": "S",+          "min": 6,+          "typ": null,+          "max": null,+          "conditions": "VDS = 25V ID = 8A",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input capacitance",+          "symbol": "Ciss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 400,+          "max": null,+          "conditions": "VDS = 15V, f = 1MHz, VGS = 0",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output capacitance",+          "symbol": "Coss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 103,+          "max": null,+          "conditions": "VDS = 15V, f = 1MHz, VGS = 0",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Reverse transfer capacitance",+          "symbol": "Crss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 41.5,+          "max": null,+          "conditions": "VDS = 15V, f = 1MHz, VGS = 0",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Total gate charge",+          "symbol": "Qg",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 14.1,+          "max": null,+          "conditions": "VDD = 30 ID = 16A VGS = 10V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Gate-source charge",+          "symbol": "Qgs",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 2.8,+          "max": null,+          "conditions": "VDD = 30 ID = 16A VGS = 10V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Gate-drain charge",+          "symbol": "Qgd",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 5.4,+          "max": null,+          "conditions": "VDD = 30 ID = 16A VGS = 10V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Turn-on delay time",+          "symbol": "td(on)",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 4,+          "max": null,+          "conditions": "VDD = 30V, ID = 8A, RG = 4.7Ω, VGS = 10V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Rise time",+          "symbol": "tr",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 15,+          "max": null,+          "conditions": "VDD = 30V, ID = 8A, RG = 4.7Ω, VGS = 10V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Turn-off delay time",+          "symbol": "td(off)",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 16,+          "max": null,+          "conditions": "VDD = 30V, ID = 8A, RG = 4.7Ω, VGS = 10V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Fall time",+          "symbol": "tf",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 5.5,+          "max": null,+          "conditions": "VDD = 30V, ID = 8A, RG = 4.7Ω, VGS = 10V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Source-drain current",+          "symbol": "ISD",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 16,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Source-drain current (pulsed)",+          "symbol": "ISDM",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 64,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Forward on voltage",+          "symbol": "VSD",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1.5,+          "conditions": "ISD = 8A VGS = 0",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Reverse recovery time",+          "symbol": "trr",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 49,+          "max": null,+          "conditions": "ISD = 16A, di/dt = 100A/µs, VDD = 20V, TJ = 150°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Reverse recovery charge",+          "symbol": "Qrr",+          "kind": "electrical",+          "unit": "µC",+          "min": null,+          "typ": 78,+          "max": null,+          "conditions": "ISD = 16A, di/dt = 100A/µs, VDD = 20V, TJ = 150°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Reverse recovery current",+          "symbol": "IRRM",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 3.2,+          "max": null,+          "conditions": "ISD = 16A, di/dt = 100A/µs, VDD = 20V, TJ = 150°C",+          "source_page": 4,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],