Ray sp339eer1-l: component.models_3d pose record per STEP (Z-up, seated z=0, pad-centre origin, identity binding) 2811f90
{
  "schema_version": 1,
  "type": "component",
  "slug": "sp339eer1-l",
  "title": "SP339EER1-L",
  "brief": "MaxLinear RS-485 / RS-422 ICs, QFN-40-EP(6x6). Pinout extracted from the datasheet, KiCad symbol/footprint/3D.",
  "version": "0.2.0",
  "license": "CC-BY-SA-4.0",
  "tags": [
    "component",
    "interface",
    "sp339eer1-l"
  ],
  "component": {
    "mpn": "SP339EER1-L",
    "manufacturer": "MaxLinear",
    "package": "QFN-40-EP(6x6)",
    "pin_count": 40,
    "category": "Interface",
    "subcategory": "RS-485 / RS-422 ICs",
    "datasheet": "https://datasheet.lcsc.com/datasheet/pdf/c2dc171a0af415dfec9968c068dfb18a.pdf",
    "parts": {
      "symbol": "sp339eer1-l.kicad_sym",
      "footprint": "sp339eer1-l.kicad_mod",
      "model_3d": "sp339eer1-l-etched.glb",
      "model_3d_plain": "sp339eer1-l.glb",
      "model_3d_step": "sp339eer1-l-etched.step",
      "model_3d_step_plain": "sp339eer1-l.step",
      "lbr": "sp339eer1-l.lbr"
    },
    "distributor_links": {},
    "pins": [
      {
        "number": "1",
        "name": "L1/R1_OUT",
        "type": "output",
        "description": "Mode-dependent: RS-232 R1 receiver output (MODE=00/01) or logic '1' output (MODE=10/11). Named L1 as CMOS/TTL logic-side signal."
      },
      {
        "number": "2",
        "name": "L2/R2_OUT/R1_OUT",
        "type": "output",
        "description": "Mode-dependent: RS-232 R2 receiver output in mode 00/01, RS-485/422 R1 receiver output in mode 10/11."
      },
      {
        "number": "3",
        "name": "L3/T1_IN",
        "type": "input",
        "description": "Mode-dependent T1 (driver 1) CMOS/TTL logic input in all active modes."
      },
      {
        "number": "4",
        "name": "L4/T2_IN",
        "type": "input",
        "description": "RS-232 T2 driver logic input in mode 00/01; unused in RS-485/422 modes."
      },
      {
        "number": "5",
        "name": "L6/R3_OUT",
        "type": "output",
        "description": "RS-232 R3 receiver output in mode 00/01; logic '1' in RS-485/422 modes."
      },
      {
        "number": "6",
        "name": "L7/T3_IN",
        "type": "input",
        "description": "RS-232 T3 driver logic input in mode 00/01; unused in RS-485/422 modes."
      },
      {
        "number": "7",
        "name": "L8/R4_OUT",
        "type": "output",
        "description": "RS-232 R4 receiver output in mode 00/01; logic '1' in RS-485/422 modes."
      },
      {
        "number": "8",
        "name": "L9/R5_OUT",
        "type": "output",
        "description": "RS-232 R5 receiver output in mode 00/01; logic '1' in RS-485/422 modes."
      },
      {
        "number": "9",
        "name": "VCC",
        "type": "power_in",
        "description": "Positive supply input, 3.3V or 5V single-supply operation."
      },
      {
        "number": "10",
        "name": "GND",
        "type": "power_in",
        "description": "Ground return."
      },
      {
        "number": "11",
        "name": "SLEW",
        "type": "input",
        "description": "Slew-rate select. SLEW=VCC enables 250 kbps slew-rate limiting on all drivers to reduce EMI."
      },
      {
        "number": "12",
        "name": "DIR1",
        "type": "input",
        "description": "Direction control for RS-485/422 driver/receiver 1. High enables T1 (and disables R1 in half-duplex mode 10)."
      },
      {
        "number": "13",
        "name": "NC",
        "type": "unconnected",
        "description": "Not connected internally; leave floating or tie as convenient for layout."
      },
      {
        "number": "14",
        "name": "MODE0",
        "type": "input",
        "description": "Protocol select bit 0. Combined with MODE1 selects RS-232 loopback (00), RS-232 (01), RS-485/422 half-duplex (10), or RS-485/422 full-duplex (11)."
      },
      {
        "number": "15",
        "name": "MODE1",
        "type": "input",
        "description": "Protocol select bit 1. See MODE0 for combined mode encoding."
      },
      {
        "number": "16",
        "name": "NC",
        "type": "unconnected",
        "description": "Not connected internally."
      },
      {
        "number": "17",
        "name": "TERM",
        "type": "input",
        "description": "Termination enable. In RS-485/422 modes, high enables the internal 120Ω-class receiver termination network across the bus inputs."
      },
      {
        "number": "18",
        "name": "NC",
        "type": "unconnected",
        "description": "Not connected internally."
      },
      {
        "number": "19",
        "name": "ENABLE",
        "type": "input",
        "description": "Device enable. ENABLE=VCC for normal operation; ENABLE=0V puts the device into low-power shutdown (<10 µA)."
      },
      {
        "number": "20",
        "name": "VCC",
        "type": "power_in",
        "description": "Positive supply input, 3.3V or 5V."
      },
      {
        "number": "21",
        "name": "R9/R5_IN",
        "type": "input",
        "description": "RS-232 R5 receiver bus input in mode 00/01; unused in RS-485/422 modes. ±18V tolerant."
      },
      {
        "number": "22",
        "name": "R8/R4_IN",
        "type": "input",
        "description": "RS-232 R4 receiver bus input in mode 00/01; unused in RS-485/422 modes. ±18V tolerant."
      },
      {
        "number": "23",
        "name": "GND",
        "type": "power_in",
        "description": "Ground return."
      },
      {
        "number": "24",
        "name": "R7/T3_OUT",
        "type": "output",
        "description": "RS-232 T3 driver bus output in mode 00/01; unused in RS-485/422 modes. ±18V tolerant."
      },
      {
        "number": "25",
        "name": "R6/R3_IN",
        "type": "input",
        "description": "RS-232 R3 receiver bus input in mode 00/01; unused in RS-485/422 modes."
      },
      {
        "number": "26",
        "name": "GND",
        "type": "power_in",
        "description": "Ground return."
      },
      {
        "number": "27",
        "name": "R4/T2_OUT/R1_IN_B",
        "type": "bidirectional",
        "description": "Mode-dependent bus pin: RS-232 T2 driver output in mode 01; RS-485/422 R1 receiver input B in mode 11 (full duplex)."
      },
      {
        "number": "28",
        "name": "R3/T1_OUT/R1_IN_A",
        "type": "bidirectional",
        "description": "Mode-dependent bus pin: RS-232 T1 driver output in mode 01; RS-485/422 R1 receiver input A in mode 11 (full duplex)."
      },
      {
        "number": "29",
        "name": "GND",
        "type": "power_in",
        "description": "Ground return."
      },
      {
        "number": "30",
        "name": "R2/R2_IN/R1_IN_A_T1_OUT_A/T1_OUT_A",
        "type": "bidirectional",
        "description": "Mode-dependent bus pin: RS-232 R2 receiver input (mode 01); RS-485/422 half-duplex R1 input A / T1 output A (mode 10); full-duplex T1 output A (mode 11)."
      },
      {
        "number": "31",
        "name": "R1/R1_IN/R1_IN_B_T1_OUT_B/T1_OUT_B",
        "type": "bidirectional",
        "description": "Mode-dependent bus pin: RS-232 R1 receiver input (mode 01); RS-485/422 half-duplex R1 input B / T1 output B (mode 10); full-duplex T1 output B (mode 11)."
      },
      {
        "number": "32",
        "name": "VCC",
        "type": "power_in",
        "description": "Positive supply, 3.3V or 5V. Bypass with 1.0 µF to ground for supply decoupling."
      },
      {
        "number": "33",
        "name": "VSS",
        "type": "power_out",
        "description": "Charge-pump negative supply rail (internally generated). Bypass with 0.1 µF to ground."
      },
      {
        "number": "34",
        "name": "C2-",
        "type": "passive",
        "description": "Charge-pump capacitor 2 negative lead. Connect external 0.1 µF flying cap between C2+ and C2-."
      },
      {
        "number": "35",
        "name": "C1-",
        "type": "passive",
        "description": "Charge-pump capacitor 1 negative lead. Connect external 0.1 µF flying cap between C1+ and C1-."
      },
      {
        "number": "36",
        "name": "GND",
        "type": "power_in",
        "description": "Ground return."
      },
      {
        "number": "37",
        "name": "C1+",
        "type": "passive",
        "description": "Charge-pump capacitor 1 positive lead. 0.1 µF flying capacitor to C1-."
      },
      {
        "number": "38",
        "name": "VCC",
        "type": "power_in",
        "description": "Positive supply, 3.3V or 5V."
      },
      {
        "number": "39",
        "name": "C2+",
        "type": "passive",
        "description": "Charge-pump capacitor 2 positive lead. 0.1 µF flying capacitor to C2-."
      },
      {
        "number": "40",
        "name": "VDD",
        "type": "power_out",
        "description": "Charge-pump positive supply rail (internally generated). Bypass with 0.1 µF to ground."
      }
    ],
    "provenance": {
      "extractor": "ds2sf",
      "datasheet": {
        "url": "https://datasheet.lcsc.com/datasheet/pdf/c2dc171a0af415dfec9968c068dfb18a.pdf",
        "pages": 24,
        "sha256": "a608a7bf488833bc",
        "source_tier": "mfr"
      },
      "cad": "KiCad official (CC-BY-SA 4.0)",
      "pins": {
        "total": 40,
        "described": 40,
        "cites_pages": true,
        "refuses_to_fabricate": true
      }
    },
    "viewers": {
      "symbol": "viewers/symbol.html",
      "footprint": "viewers/footprint.html"
    },
    "models_3d": [
      {
        "file": "sp339eer1-l.step",
        "role": "plain",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          6,
          6,
          1
        ],
        "zmin_mm": 0,
        "centre_offset_mm": 0,
        "footprint_binding": "identity",
        "sha256": "e5b4286c2329085d9ef7f90d5eb5bf41a435241ecc1baaf1383823b6d6a946ae",
        "checked": "2026-10-07",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      },
      {
        "file": "sp339eer1-l-etched.step",
        "role": "eda",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          6,
          6,
          1
        ],
        "zmin_mm": 0,
        "centre_offset_mm": 0,
        "footprint_binding": "identity",
        "sha256": "d211c6891c63798ff9c720a0add5dd95052b80076be8ed5f61f47f56988d1f9f",
        "checked": "2026-10-07",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      }
    ]
  },
  "metadata": {
    "specs": {
      "Manufacturer": "MaxLinear",
      "Package": "QFN-40-EP(6x6)",
      "Category": "Interface",
      "Pins": "40"
    }
  },
  "sections": [
    "hero",
    "viewers",
    "readme",
    "breadcrumbs",
    "info"
  ],
  "discovery_triggers": [
    "sp339eer1-l"
  ],
  "discovery_pitch": "SP339EER1-L (MaxLinear) component page with datasheet-verified CAD.",
  "author": {
    "name": "Ray"
  },
  "dependencies": {},
  "hero": {
    "type": "image",
    "path": "docs/hero.png"
  },
  "files": [
    "page.json",
    "README.md",
    "sp339eer1-l.kicad_sym",
    "sp339eer1-l.kicad_mod",
    "sp339eer1-l.glb",
    "sp339eer1-l.step",
    "sp339eer1-l-etched.step",
    "sp339eer1-l.lbr",
    "docs/hero.png",
    "docs/sp339eer1-l-datasheet.pdf",
    "viewers/symbol.html",
    "viewers/footprint.html"
  ],
  "visibility": {
    "public": true
  },
  "variants": [
    {
      "mpn": "SP339EER1-L",
      "kind": "packaging"
    },
    {
      "mpn": "SP339EER1-L/TR",
      "kind": "packaging"
    }
  ],
  "updated_at": "2026-09-25T07:58:32.357Z"
}