← Commit history

Publish 0.1.1

Ray ·084c2f3555 · ·parent d85af7f
2 files changed +430−10
package.json+423−4
@@ -1,6 +1,6 @@ {   "slug": "sn74cb3t1g125dbvr",-  "version": "0.1.0",+  "version": "0.1.1",   "type": "component",   "description": "Texas Instruments Analog Switches, Multiplexers, SOT-23-5. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",   "tags": [@@ -29,7 +29,8 @@     "viewers/footprint.html",     "sn74cb3t1g125dbvr-hero.glb",     "sn74cb3t1g125dbvr-hero.overlay.json",-    "sn74cb3t1g125dbvr-etched.glb"+    "sn74cb3t1g125dbvr-etched.glb",+    "sn74cb3t1g125dbvr-etched.step"   ],   "component": {     "mpn": "SN74CB3T1G125DBVR",@@ -43,7 +44,7 @@       "symbol": "sn74cb3t1g125dbvr.kicad_sym",       "footprint": "sn74cb3t1g125dbvr.kicad_mod",       "model_3d": "sn74cb3t1g125dbvr-hero.glb",-      "model_3d_plain": "sn74cb3t1g125dbvr-etched.glb",+      "model_3d_plain": "sn74cb3t1g125dbvr.glb",       "model_3d_step": "sn74cb3t1g125dbvr-etched.step",       "model_3d_step_plain": "sn74cb3t1g125dbvr.step",       "lbr": "sn74cb3t1g125dbvr.lbr"@@ -170,5 +171,423 @@         "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"       }     ]-  }+  },+  "title": "SN74CB3T1G125DBVR",+  "brief": "Texas Instruments Analog Switches, Multiplexers, SOT-23-5. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "Texas Instruments",+      "Package": "SOT-23-5",+      "Category": "Interface",+      "Pins": "5"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "c85b9867c881127e11df04eded2bb8de69fa8fe2542f6b4a6140f946f08f4c3f",+      "rows": [+        {+          "name": "Supply voltage range",+          "symbol": "VCC",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.5,+          "typ": null,+          "max": 7,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Control input voltage range",+          "symbol": "VIN",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.5,+          "typ": null,+          "max": 7,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Switch I/O voltage range",+          "symbol": "VI/O",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.5,+          "typ": null,+          "max": 7,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Control input clamp current",+          "symbol": "IIK",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": -50,+          "conditions": "VIN < 0",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "I/O port clamp current",+          "symbol": "II/OK",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": -50,+          "conditions": "VI/O < 0",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "ON-state switch current",+          "symbol": "IO",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": -128,+          "typ": null,+          "max": 128,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Continuous current through VCC or GND",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": -100,+          "typ": null,+          "max": 100,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Package thermal impedance (DBV package)",+          "symbol": "θJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 206,+          "conditions": "DBV package, per JESD 51-7",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature range",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Supply voltage",+          "symbol": "VCC",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 2.3,+          "typ": null,+          "max": 3.6,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "High-level control input voltage",+          "symbol": "VIH",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 1.7,+          "typ": null,+          "max": 5.5,+          "conditions": "VCC = 2.3 V to 2.7 V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "High-level control input voltage",+          "symbol": "VIH",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 2,+          "typ": null,+          "max": 5.5,+          "conditions": "VCC = 2.7 V to 3.6 V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Low-level control input voltage",+          "symbol": "VIL",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 0,+          "typ": null,+          "max": 0.7,+          "conditions": "VCC = 2.3 V to 2.7 V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Low-level control input voltage",+          "symbol": "VIL",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 0,+          "typ": null,+          "max": 0.8,+          "conditions": "VCC = 2.7 V to 3.6 V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Data input/output voltage",+          "symbol": "VI/O",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 0,+          "typ": null,+          "max": 5.5,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Operating free-air temperature",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input clamp voltage",+          "symbol": "VIK",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": -1.2,+          "conditions": "VCC = 3 V, II = -18 mA",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Control inputs input current",+          "symbol": "II",+          "kind": "electrical",+          "unit": "µA",+          "min": -10,+          "typ": null,+          "max": 10,+          "conditions": "VCC = 3.6 V, VIN = 3.6 V to 5.5 V or GND",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "I/O input current",+          "symbol": "II",+          "kind": "electrical",+          "unit": "µA",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "VI = VCC – 0.7 V to 5.5 V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "ON-state input current",+          "symbol": "II",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": -40,+          "conditions": "VI = 0.7 V to VCC – 0.7 V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Input current at low data voltage",+          "symbol": "II",+          "kind": "electrical",+          "unit": "µA",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "VI = 0 to 0.7 V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Off-state leakage current",+          "symbol": "IOZ",+          "kind": "electrical",+          "unit": "µA",+          "min": -10,+          "typ": null,+          "max": 10,+          "conditions": "VCC = 3.6 V, VO = 0 to 5.5 V, VI = 0, Switch OFF, VIN = VCC or GND",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Power-off leakage current",+          "symbol": "Ioff",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "VCC = 0, VO = 0 to 5.5 V, VI = 0",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Quiescent supply current",+          "symbol": "ICC",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "VI = VCC or GND",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Increase in supply current per control input",+          "symbol": "ΔICC",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 300,+          "conditions": "VCC = 3 V to 3.6 V, One input at VCC – 0.6 V, Other inputs at VCC or GND",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Control input capacitance",+          "symbol": "Cin",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 3,+          "max": null,+          "conditions": "VCC = 3.3 V, VIN = VCC or GND",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Input/output capacitance, switch OFF",+          "symbol": "Cio(OFF)",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 5,+          "max": null,+          "conditions": "VCC = 3.3 V, VI/O = 5.5 V, 3.3 V, or GND, Switch OFF, VIN = VCC or GND",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "ON-state resistance",+          "symbol": "ron",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 5,+          "max": 8,+          "conditions": "VCC = 2.3 V, VI = 0, IO = 24 mA",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "ON-state resistance",+          "symbol": "ron",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 5,+          "max": 7,+          "conditions": "VCC = 3 V, VI = 0, IO = 64 mA",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Enable time",+          "symbol": "ten",+          "kind": "timing",+          "unit": "ns",+          "min": 1,+          "typ": null,+          "max": 7.5,+          "conditions": "VCC = 2.5 V ± 0.2 V, see Figure 2",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Enable time",+          "symbol": "ten",+          "kind": "timing",+          "unit": "ns",+          "min": 1,+          "typ": null,+          "max": 6.5,+          "conditions": "VCC = 3.3 V ± 0.3 V, see Figure 2",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Disable time",+          "symbol": "tdis",+          "kind": "timing",+          "unit": "ns",+          "min": 1,+          "typ": null,+          "max": 5.5,+          "conditions": "VCC = 2.5 V ± 0.2 V, see Figure 2",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Disable time",+          "symbol": "tdis",+          "kind": "timing",+          "unit": "ns",+          "min": 1,+          "typ": null,+          "max": 6,+          "conditions": "VCC = 3.3 V ± 0.3 V, see Figure 2",+          "source_page": 4,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "sn74cb3t1g125dbvr"+  ],+  "discovery_pitch": "SN74CB3T1G125DBVR (Texas Instruments) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+  "visibility": "public" }
page.json+7−6
@@ -4,7 +4,7 @@   "slug": "sn74cb3t1g125dbvr",   "title": "SN74CB3T1G125DBVR",   "brief": "Texas Instruments Analog Switches, Multiplexers, SOT-23-5. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",-  "version": "0.1.0",+  "version": "0.1.1",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -25,7 +25,7 @@       "symbol": "sn74cb3t1g125dbvr.kicad_sym",       "footprint": "sn74cb3t1g125dbvr.kicad_mod",       "model_3d": "sn74cb3t1g125dbvr-hero.glb",-      "model_3d_plain": "sn74cb3t1g125dbvr-etched.glb",+      "model_3d_plain": "sn74cb3t1g125dbvr.glb",       "model_3d_step": "sn74cb3t1g125dbvr-etched.step",       "model_3d_step_plain": "sn74cb3t1g125dbvr.step",       "lbr": "sn74cb3t1g125dbvr.lbr"@@ -599,9 +599,10 @@     "viewers/footprint.html",     "sn74cb3t1g125dbvr-hero.glb",     "sn74cb3t1g125dbvr-hero.overlay.json",-    "sn74cb3t1g125dbvr-etched.glb"+    "sn74cb3t1g125dbvr-etched.glb",+    "sn74cb3t1g125dbvr-etched.step"   ],-  "visibility": {-    "public": true-  }+  "visibility": "public",+  "description": "Texas Instruments Analog Switches, Multiplexers, SOT-23-5. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+  "org": "adom" }\ No newline at end of file