main
Ray Publish 0.1.1 f58f54e
{
  "schema_version": 1,
  "type": "component",
  "slug": "sn65hvd1040dr",
  "title": "SN65HVD1040DR",
  "brief": "Texas Instruments CAN Controllers, SOIC-8. Pinout extracted from the datasheet, KiCad symbol/footprint/3D.",
  "version": "0.1.1",
  "license": "CC-BY-SA-4.0",
  "tags": [
    "component",
    "interface",
    "sn65hvd1040dr"
  ],
  "component": {
    "mpn": "SN65HVD1040DR",
    "manufacturer": "Texas Instruments",
    "package": "SOIC-8",
    "pin_count": 8,
    "category": "Interface",
    "subcategory": "CAN Controllers",
    "datasheet": "https://www.ti.com/lit/ds/symlink/sn65hvd1040.pdf",
    "parts": {
      "symbol": "sn65hvd1040dr.kicad_sym",
      "footprint": "sn65hvd1040dr.kicad_mod",
      "model_3d": "sn65hvd1040dr-hero.glb",
      "model_3d_plain": "sn65hvd1040dr.glb",
      "model_3d_step": "sn65hvd1040dr-etched.step",
      "model_3d_step_plain": "sn65hvd1040dr.step",
      "lbr": "sn65hvd1040dr.lbr"
    },
    "distributor_links": {},
    "pins": [
      {
        "number": "1",
        "name": "TXD",
        "type": "input",
        "description": "CAN transmit data input from the CAN controller. LOW drives the bus to the dominant state; HIGH allows the bus to go to the recessive state. Input voltage range 0 to 5.25 V (VIH ≥ 2 V, VIL ≤ 0.8 V)."
      },
      {
        "number": "2",
        "name": "GND",
        "type": "power_in",
        "description": "Device ground reference."
      },
      {
        "number": "3",
        "name": "VCC",
        "type": "power_in",
        "description": "Transceiver 5-V supply. Recommended operating range 4.75 V to 5.25 V. Decouple to GND close to the pin."
      },
      {
        "number": "4",
        "name": "RXD",
        "type": "output",
        "description": "CAN receive data output to the CAN controller. LOW indicates dominant bus state; HIGH indicates recessive bus state. IOH = -2 mA, IOL = 2 mA."
      },
      {
        "number": "5",
        "name": "SPLIT",
        "type": "output",
        "description": "Reference output voltage (VCC/2) intended to bias the common-mode of a split-termination network on the CAN bus for improved EMC."
      },
      {
        "number": "6",
        "name": "CANL",
        "type": "bidirectional",
        "description": "Low-level CAN bus line. Differential I/O with CANH; withstands -27 V to 40 V bus faults and ±200 V transients per ISO 7637. Common-mode range -12 V to 12 V."
      },
      {
        "number": "7",
        "name": "CANH",
        "type": "bidirectional",
        "description": "High-level CAN bus line. Differential I/O with CANL; withstands -27 V to 40 V bus faults and ±200 V transients per ISO 7637. Common-mode range -12 V to 12 V."
      },
      {
        "number": "8",
        "name": "STB",
        "type": "input",
        "description": "Mode select input. Strong pulldown to GND selects high-speed mode; strong pullup to VCC selects low-power standby (bus-monitor) mode. VIH ≥ 2 V, VIL ≤ 0.8 V."
      }
    ],
    "provenance": {
      "extractor": "ds2sf",
      "datasheet": {
        "url": "https://www.ti.com/lit/ds/symlink/sn65hvd1040.pdf",
        "pages": 35,
        "sha256": "05d443ce8d4c4593",
        "source_tier": "mfr"
      },
      "cad": "KiCad official (CC-BY-SA 4.0)",
      "pins": {
        "total": 8,
        "described": 8,
        "cites_pages": true,
        "refuses_to_fabricate": true
      }
    },
    "viewers": {
      "symbol": "viewers/symbol.html",
      "footprint": "viewers/footprint.html"
    },
    "models_3d": [
      {
        "file": "sn65hvd1040dr.step",
        "role": "plain",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          6,
          4.9,
          1.75
        ],
        "zmin_mm": 0,
        "centre_offset_mm": 0,
        "footprint_binding": "identity",
        "sha256": "07f46cff378d30e6c27dfd5a03092c795323f86d91c71fc7e743f4f418dc553a",
        "checked": "2026-10-07",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      },
      {
        "file": "sn65hvd1040dr-etched.step",
        "role": "eda",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          6,
          4.9,
          1.75
        ],
        "zmin_mm": 0,
        "centre_offset_mm": 0,
        "footprint_binding": "identity",
        "sha256": "401626209b536a5d3df36aa791ca9410c12e315979492af115b2eef3e7ea053d",
        "checked": "2026-10-07",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      }
    ]
  },
  "metadata": {
    "specs": {
      "Manufacturer": "Texas Instruments",
      "Package": "SOIC-8",
      "Category": "Interface",
      "Pins": "8"
    }
  },
  "variants": [
    {
      "mpn": "SN65HVD1040DR",
      "kind": "packaging"
    },
    {
      "mpn": "SN65HVD1040DRD",
      "kind": "packaging"
    }
  ],
  "sections": [
    "hero",
    "viewers",
    "readme",
    "breadcrumbs",
    "info"
  ],
  "discovery_triggers": [
    "sn65hvd1040dr"
  ],
  "discovery_pitch": "SN65HVD1040DR (Texas Instruments) component page with datasheet-verified CAD.",
  "author": {
    "name": "Ray"
  },
  "dependencies": {},
  "hero": {
    "type": "image",
    "path": "docs/hero.png"
  },
  "files": [
    "page.json",
    "README.md",
    "sn65hvd1040dr.kicad_sym",
    "sn65hvd1040dr.kicad_mod",
    "sn65hvd1040dr.glb",
    "sn65hvd1040dr.step",
    "sn65hvd1040dr.lbr",
    "docs/hero.png",
    "docs/sn65hvd1040dr-datasheet.pdf",
    "viewers/symbol.html",
    "viewers/footprint.html",
    "sn65hvd1040dr-etched.step",
    "sn65hvd1040dr-hero.glb",
    "sn65hvd1040dr-hero.overlay.json"
  ],
  "visibility": "public",
  "updated_at": "2026-09-25T06:23:17.857Z",
  "description": "Texas Instruments CAN Controllers, SOIC-8. Datasheet-verified pinout, KiCad symbol/footprint/3D.",
  "org": "adom"
}