main
Ray
Set visibility: public
200a34b
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334
{
"schema_version": 1,
"type": "component",
"slug": "smd1812p075tf-24",
"title": "SMD1812P075TF/24",
"brief": "RUILON Shenzhen Ruilongyuan Elec Resettable Fuses, 1812. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",
"version": "0.1.0",
"license": "CC-BY-SA-4.0",
"tags": [
"component",
"circuit protection",
"smd1812p075tf",
"factory-2.0.0",
"extractor-text"
],
"component": {
"mpn": "SMD1812P075TF/24",
"manufacturer": "RUILON Shenzhen Ruilongyuan Elec",
"package": "1812",
"pin_count": 2,
"category": "Circuit Protection",
"subcategory": "Resettable Fuses",
"datasheet": "https://datasheet.lcsc.com/datasheet/pdf/cfa74b12b2251ef3c7fa909bdad1e8a9.pdf",
"parts": {
"symbol": "smd1812p075tf-24.kicad_sym",
"footprint": "smd1812p075tf-24.kicad_mod",
"model_3d": "smd1812p075tf-24-hero.glb",
"model_3d_step": "smd1812p075tf-24.step",
"lbr": "smd1812p075tf-24.lbr",
"model_3d_plain": "smd1812p075tf-24.glb"
},
"distributor_links": {
"lcsc": "C12557"
},
"distributor_check": {
"checked_at": "2026-11-16T18:46:32Z",
"source": "Component Ocean /api/assign-pns",
"digikey": {
"pn": null,
"status": "no match"
},
"mouser": {
"pn": null,
"status": "no match"
}
},
"pins": [
{
"number": "1",
"name": "1",
"type": "passive",
"description": "First terminal of the non-polarized SMD1812P075TF PTC resettable fuse (series element), rated Ihold 0.75 A, Itrip 1.5 A, Vmax 13.2 VDC and Imax 30 A."
},
{
"number": "2",
"name": "2",
"type": "passive",
"description": "Second terminal of the series PTC element, interchangeable with the first, with Ri min 0.09 ohm and R1max 0.45 ohm and an operating ambient of -40 °C to +85 °C."
}
],
"provenance": {
"extractor": "extract_pins 0.3",
"factory_chain": {
"factory": "2.0.0",
"extractor": "extract_pins 0.3",
"primary_model": "claude-sonnet-5-5",
"primary_mode": "text",
"consensus_model": "claude-opus-5-5",
"consensus": "agreed",
"guards": "pin_guards 0.1: passed",
"guard_notes": [
"extractor flagged: The datasheet is for a two-terminal PTC resettable fuse and gives no pin numbers or pin names. Pins "
],
"pages_sent": 12,
"cost_usd": 0.1827,
"at": "2026-11-16T18:46:19"
},
"datasheet": {
"url": "https://datasheet.lcsc.com/datasheet/pdf/cfa74b12b2251ef3c7fa909bdad1e8a9.pdf",
"pages": 12,
"sha256": "fd00a32cd6588696",
"source_tier": "lcsc"
},
"cad": "KiCad official (CC-BY-SA 4.0)",
"model_3d_generated": {
"generator": "factory/gen_pkg3d.py",
"family": "_1806_",
"height_mm": 0.9,
"height_basis": "family nominal (no datasheet A read)",
"standoff_mm": 0
},
"pins": {
"total": 2,
"described": 2,
"cites_pages": true,
"refuses_to_fabricate": true
}
},
"viewers": {
"symbol": "viewers/symbol.html",
"footprint": "viewers/footprint.html"
},
"models_3d": [
{
"file": "smd1812p075tf-24.step",
"role": "plain",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
4.52,
3.22,
0.9
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "44dc449e34a0b81a8c11fc3bd080038ca77e85dcb7b4a2a826877114bba0f0a9",
"checked": "2026-11-16",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
}
]
},
"metadata": {
"specs": {
"Manufacturer": "RUILON Shenzhen Ruilongyuan Elec",
"Package": "1812",
"Category": "Circuit Protection",
"Pins": "2"
},
"characteristics": {
"version": 1,
"source": "datasheet",
"datasheet_sha256": "fd00a32cd6588696ccfbaa7834793c5a9f5f2a933d01019303bf2dbe730d488e",
"rows": [
{
"name": "Hold current",
"symbol": "Ihold",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": 0.75,
"max": null,
"conditions": "25°C still air, max current device will not trip",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Trip current",
"symbol": "Itrip",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": 1.5,
"max": null,
"conditions": "Minimum current at which device will always trip, 25°C still air",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Maximum operating voltage",
"symbol": "Vmax",
"kind": "absolute_maximum",
"unit": "VDC",
"min": null,
"typ": null,
"max": 13.2,
"conditions": "At rated current (Imax)",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Maximum fault current",
"symbol": "Imax",
"kind": "absolute_maximum",
"unit": "A",
"min": null,
"typ": null,
"max": 30,
"conditions": "At rated voltage (Vmax)",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Time to trip",
"symbol": "",
"kind": "timing",
"unit": "s",
"min": null,
"typ": null,
"max": 0.2,
"conditions": "Tmax at 8 A",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Power dissipation in tripped state",
"symbol": "Pd",
"kind": "electrical",
"unit": "W",
"min": null,
"typ": 0.8,
"max": null,
"conditions": "25°C still air at rated voltage",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Minimum resistance prior to tripping",
"symbol": "Rimin",
"kind": "electrical",
"unit": "Ω",
"min": 0.09,
"typ": null,
"max": null,
"conditions": "25°C",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Maximum resistance one hour post reflow",
"symbol": "R1max",
"kind": "electrical",
"unit": "Ω",
"min": null,
"typ": null,
"max": 0.45,
"conditions": "Measured one hour post reflow",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Ambient operating temperature",
"symbol": "",
"kind": "recommended_operating",
"unit": "°C",
"min": -40,
"typ": null,
"max": 85,
"conditions": "Ambient operating conditions",
"source_page": 3,
"source": "datasheet"
},
{
"name": "Maximum surface temperature in tripped state",
"symbol": "",
"kind": "absolute_maximum",
"unit": "°C",
"min": null,
"typ": null,
"max": 125,
"conditions": "Tripped state",
"source_page": 3,
"source": "datasheet"
},
{
"name": "Hold current at -40 °C",
"symbol": "Ih",
"kind": "temperature_coefficient",
"unit": "A",
"min": null,
"typ": 1.1,
"max": null,
"conditions": "Ambient -40 °C",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Hold current at 85 °C",
"symbol": "Ih",
"kind": "temperature_coefficient",
"unit": "A",
"min": null,
"typ": 0.35,
"max": null,
"conditions": "Ambient 85 °C",
"source_page": 6,
"source": "datasheet"
},
{
"name": "Peak reflow temperature",
"symbol": "TP",
"kind": "absolute_maximum",
"unit": "°C",
"min": null,
"typ": null,
"max": 260,
"conditions": "Pb-free reflow, 260 +0/-5°C, do not exceed 260°C",
"source_page": 7,
"source": "datasheet"
}
]
}
},
"variants": [],
"sections": [
"hero",
"viewers",
"readme",
"breadcrumbs",
"info"
],
"discovery_triggers": [
"smd1812p075tf"
],
"discovery_pitch": "SMD1812P075TF (RUILON Shenzhen Ruilongyuan Elec) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
"author": {
"name": "Ray"
},
"dependencies": {},
"hero": {
"type": "image",
"path": "docs/hero.png"
},
"files": [
"page.json",
"README.md",
"smd1812p075tf-24.kicad_sym",
"smd1812p075tf-24.kicad_mod",
"smd1812p075tf-24.glb",
"smd1812p075tf-24.step",
"smd1812p075tf-24.lbr",
"docs/hero.png",
"docs/smd1812p075tf-24-datasheet.pdf",
"viewers/symbol.html",
"viewers/footprint.html",
"smd1812p075tf-24-hero.glb",
"smd1812p075tf-24-hero.overlay.json"
],
"visibility": {
"public": true
}
}