123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176
{
"slug": "sit1040qt",
"version": "0.1.1",
"type": "component",
"description": "SIT CAN Controllers, SOP-8. Datasheet-verified pinout, KiCad symbol/footprint/3D.",
"tags": [
"component",
"interface",
"sit1040qt"
],
"dependencies": {},
"hero": {
"type": "image",
"path": "docs/hero.png"
},
"files": [
"page.json",
"README.md",
"sit1040qt.kicad_sym",
"sit1040qt.kicad_mod",
"sit1040qt.glb",
"sit1040qt.step",
"sit1040qt.lbr",
"docs/hero.png",
"docs/sit1040qt-datasheet.pdf",
"viewers/symbol.html",
"viewers/footprint.html",
"sit1040qt-etched.step",
"sit1040qt-hero.glb",
"sit1040qt-hero.overlay.json"
],
"component": {
"mpn": "SIT1040QT",
"manufacturer": "SIT",
"package": "SOP-8",
"pin_count": 8,
"category": "Interface",
"subcategory": "CAN Controllers",
"datasheet": "https://datasheet.lcsc.com/datasheet/pdf/8d72f242ce344554a99049ed18d76c3b.pdf",
"parts": {
"symbol": "sit1040qt.kicad_sym",
"footprint": "sit1040qt.kicad_mod",
"model_3d": "sit1040qt-hero.glb",
"model_3d_plain": "sit1040qt.glb",
"model_3d_step": "sit1040qt-etched.step",
"model_3d_step_plain": "sit1040qt.step",
"lbr": "sit1040qt.lbr"
},
"distributor_links": {},
"pins": [
{
"number": "1",
"name": "TXD",
"type": "input",
"description": "Transmit data input from the CAN controller. Internally pulled to VCC (open-state logic high); a dominant TXD held low longer than t_dom (300-700 µs) triggers the dominant time-out and forces the driver recessive. VIH ≥ 2 V, VIL ≤ 0.8 V."
},
{
"number": "2",
"name": "GND",
"type": "power_in",
"description": "Ground supply / reference for all voltages. On the DFN3*3-8 package, the exposed back pad is internally tied to GND and should be soldered to the PCB ground for improved heat dissipation."
},
{
"number": "3",
"name": "VCC",
"type": "power_in",
"description": "5 V supply voltage (operating range 4.75-5.25 V, absolute max 6 V). Typical standby ICC = 5 µA; dominant ICC ≈ 38 mA (60 Ω load)."
},
{
"number": "4",
"name": "RXD",
"type": "output",
"description": "Receive data output to the CAN controller; reads back the differential state of the CAN bus. Push-pull CMOS output: VOH ≥ 4 V at IO = -2 mA, VOL ≤ 0.4 V at IO = 2 mA. Low = dominant, High = recessive."
},
{
"number": "5",
"name": "SPLIT",
"type": "output",
"description": "Common-mode stabilization output, nominally VCC/2 (0.3·VCC to 0.7·VCC for |IO| < 500 µA). Intended to bias the mid-point of a split termination network to reduce EME on the CAN bus."
},
{
"number": "6",
"name": "CANL",
"type": "bidirectional",
"description": "Low-level CAN bus line. Bus fault tolerant from -40 V to +40 V. In dominant state driven to ~1.5 V; recessive state biased to ~0.5·VCC. Differential input resistance 30-80 kΩ."
},
{
"number": "7",
"name": "CANH",
"type": "bidirectional",
"description": "High-level CAN bus line. Bus fault tolerant from -40 V to +40 V. In dominant state driven to ~3.5 V; recessive state biased to ~0.5·VCC. Differential input resistance 30-80 kΩ."
},
{
"number": "8",
"name": "STB",
"type": "input",
"description": "Standby mode control input. Low (or open, internally pulled to GND per typical CAN transceiver convention here) = normal high-speed operation; High = low-power standby with bus wake-up capability. VIH ≥ 2.0 V, VIL ≤ 0.8 V."
}
],
"provenance": {
"extractor": "ds2sf",
"datasheet": {
"url": "https://datasheet.lcsc.com/datasheet/pdf/8d72f242ce344554a99049ed18d76c3b.pdf",
"pages": 17,
"sha256": "c6053c8797584571",
"source_tier": "lcsc"
},
"cad": "KiCad official (CC-BY-SA 4.0)",
"pins": {
"total": 8,
"described": 8,
"cites_pages": true,
"refuses_to_fabricate": true
}
},
"viewers": {
"symbol": "viewers/symbol.html",
"footprint": "viewers/footprint.html"
},
"models_3d": [
{
"file": "sit1040qt.step",
"role": "plain",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
6,
4.9,
1.75
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "07f46cff378d30e6c27dfd5a03092c795323f86d91c71fc7e743f4f418dc553a",
"checked": "2026-10-07",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
},
{
"file": "sit1040qt-etched.step",
"role": "eda",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
6,
4.9,
1.75
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "98785f8c204616ee989ad2abd498e470645d8d2740eb0b1f65b891ce784588e8",
"checked": "2026-10-07",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
}
]
},
"title": "SIT1040QT",
"brief": "SIT CAN Controllers, SOP-8. Pinout extracted from the datasheet, KiCad symbol/footprint/3D.",
"metadata": {
"specs": {
"Manufacturer": "SIT",
"Package": "SOP-8",
"Category": "Interface",
"Pins": "8"
}
},
"discovery_triggers": [
"sit1040qt"
],
"discovery_pitch": "SIT1040QT (SIT) component page with datasheet-verified CAD.",
"visibility": "public"
}