← Commit history

si2312cds-t1-ge3: specified limits as data (metadata.characteristics, 36 rows from the datasheet)

Ray ·a45775422a ·25d ago ·parent 4be7cc7
2 files changed +483−1
README.md+43
@@ -21,6 +21,49 @@ SI2312CDS-T1-GE3 from Vishay Intertech, in a SOT-23. Pinout and pin descriptions | Category | Transistors/Thyristors | | Pins | 3 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Gate-Source Leakage | IGSS | -100 |  | 100 | nA | VDS = 0 V, VGS = ±8 V | 2 |+| Gate-Source Threshold Voltage | VGS(th) | 0.45 |  | 1 | V | VDS = VGS, ID = 250 µA | 2 |+| Drain-Source On-State Resistance | RDS(on) |  | 0.0265 | 0.0318 | Ω | VGS = 4.5 V, ID = 5.0 A | 2 |+| Drain-Source On-State Resistance | RDS(on) |  | 0.0296 | 0.0356 | Ω | VGS = 2.5 V, ID = 4.7 A | 2 |+| Drain-Source On-State Resistance | RDS(on) |  | 0.0345 | 0.0414 | Ω | VGS = 1.8 V, ID = 4.3 A | 2 |+| Gate Resistance | Rg | 0.5 | 2.4 | 4.8 | Ω | f = 1 MHz | 2 |+| Total Gate Charge | Qg |  | 12 | 18 | nC | VDS = 10 V, VGS = 5 V, ID = 5.0 A | 2 |+| Total Gate Charge | Qg |  | 8.8 | 14 | nC | VDS = 10 V, VGS = 4.5 V, ID = 5.0 A | 2 |+| Turn-On Delay Time | td(on) |  | 8 | 16 | ns | VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 4.5 V, Rg = 1 Ω | 2 |+| Rise Time | tr |  | 17 | 26 | ns | VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 4.5 V, Rg = 1 Ω | 2 |+| Turn-Off Delay Time | td(off) |  | 31 | 47 | ns | VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 4.5 V, Rg = 1 Ω | 2 |+| Fall Time | tf |  | 8 | 16 | ns | VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 4.5 V, Rg = 1 Ω | 2 |+| Turn-On Delay Time | td(on) |  | 5 | 10 | ns | VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 5 V, Rg = 1 Ω | 2 |+| Rise Time | tr |  | 13 | 20 | ns | VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 5 V, Rg = 1 Ω | 2 |+| Turn-Off Delay Time | td(off) |  | 21 | 32 | ns | VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 5 V, Rg = 1 Ω | 2 |+| Fall Time | tf |  | 6 | 12 | ns | VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 5 V, Rg = 1 Ω | 2 |+| Body Diode Voltage | VSD |  | 0.75 | 1.2 | V | IS = 4 A, VGS = 0 V | 2 |+| Body Diode Reverse Recovery Time | trr |  | 12 | 20 | ns | IF = 4 A, dI/dt = 100 A/µs, TJ = 25 °C | 2 |+| Body Diode Reverse Recovery Charge | Qrr |  | 5 | 10 | nC | IF = 4 A, dI/dt = 100 A/µs, TJ = 25 °C | 2 |+| Drain-Source Voltage | VDS |  |  | 20 | V | TA = 25 °C | 1 |+| Gate-Source Voltage | VGS | -8 |  | 8 | V | TA = 25 °C | 1 |+| Continuous Drain Current | ID |  |  | 6 | A | TJ = 150 °C, TC = 25 °C (package limited) | 1 |+| Continuous Drain Current | ID |  |  | 5.1 | A | TJ = 150 °C, TC = 70 °C | 1 |+| Continuous Drain Current | ID |  |  | 5 | A | TJ = 150 °C, TA = 25 °C | 1 |+| Continuous Drain Current | ID |  |  | 4 | A | TJ = 150 °C, TA = 70 °C | 1 |+| Pulsed Drain Current | IDM |  |  | 20 | A |  | 1 |+| Continuous Source-Drain Diode Current | IS |  |  | 1.75 | A | TC = 25 °C | 1 |+| Continuous Source-Drain Diode Current | IS |  |  | 1.04 | A | TA = 25 °C | 1 |+| Maximum Power Dissipation | PD |  |  | 2.1 | W | TC = 25 °C | 1 |+| Maximum Power Dissipation | PD |  |  | 1.3 | W | TC = 70 °C | 1 |+| Maximum Power Dissipation | PD |  |  | 1.25 | W | TA = 25 °C | 1 |+| Maximum Power Dissipation | PD |  |  | 0.8 | W | TA = 70 °C | 1 |+| Operating Junction and Storage Temperature Range | TJ, Tstg | -55 |  | 150 | °C |  | 1 |+| Maximum Junction-to-Ambient | RthJA |  | 80 | 100 | °C/W | t ≤ 5 s | 1 |+| Maximum Junction-to-Ambient | RthJA |  |  | 125 | °C/W | Steady state (note d) | 1 |+| Maximum Junction-to-Foot (Drain) | RthJF |  | 40 | 60 | °C/W | Steady state | 1 |+ ## CAD (KiCad official)  - Symbol: `SI2312CDS-T1-GE3`
page.json+440−1
@@ -150,6 +150,445 @@       "Package": "SOT-23",       "Category": "Transistors/Thyristors",       "Pins": "3"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "57de5e1bf45de846",+      "rows": [+        {+          "name": "Gate-Source Leakage",+          "symbol": "IGSS",+          "kind": "electrical",+          "unit": "nA",+          "min": -100,+          "typ": null,+          "max": 100,+          "conditions": "VDS = 0 V, VGS = ±8 V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate-Source Threshold Voltage",+          "symbol": "VGS(th)",+          "kind": "electrical",+          "unit": "V",+          "min": 0.45,+          "typ": null,+          "max": 1,+          "conditions": "VDS = VGS, ID = 250 µA",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain-Source On-State Resistance",+          "symbol": "RDS(on)",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.0265,+          "max": 0.0318,+          "conditions": "VGS = 4.5 V, ID = 5.0 A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain-Source On-State Resistance",+          "symbol": "RDS(on)",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.0296,+          "max": 0.0356,+          "conditions": "VGS = 2.5 V, ID = 4.7 A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain-Source On-State Resistance",+          "symbol": "RDS(on)",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.0345,+          "max": 0.0414,+          "conditions": "VGS = 1.8 V, ID = 4.3 A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate Resistance",+          "symbol": "Rg",+          "kind": "electrical",+          "unit": "Ω",+          "min": 0.5,+          "typ": 2.4,+          "max": 4.8,+          "conditions": "f = 1 MHz",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Total Gate Charge",+          "symbol": "Qg",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 12,+          "max": 18,+          "conditions": "VDS = 10 V, VGS = 5 V, ID = 5.0 A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Total Gate Charge",+          "symbol": "Qg",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 8.8,+          "max": 14,+          "conditions": "VDS = 10 V, VGS = 4.5 V, ID = 5.0 A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-On Delay Time",+          "symbol": "td(on)",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 8,+          "max": 16,+          "conditions": "VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 4.5 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Rise Time",+          "symbol": "tr",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 17,+          "max": 26,+          "conditions": "VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 4.5 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-Off Delay Time",+          "symbol": "td(off)",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 31,+          "max": 47,+          "conditions": "VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 4.5 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Fall Time",+          "symbol": "tf",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 8,+          "max": 16,+          "conditions": "VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 4.5 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-On Delay Time",+          "symbol": "td(on)",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 5,+          "max": 10,+          "conditions": "VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 5 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Rise Time",+          "symbol": "tr",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 13,+          "max": 20,+          "conditions": "VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 5 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-Off Delay Time",+          "symbol": "td(off)",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 21,+          "max": 32,+          "conditions": "VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 5 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Fall Time",+          "symbol": "tf",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 6,+          "max": 12,+          "conditions": "VDD = 10 V, RL = 2.2 Ω, ID ≅ 4 A, VGEN = 5 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Body Diode Voltage",+          "symbol": "VSD",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": 0.75,+          "max": 1.2,+          "conditions": "IS = 4 A, VGS = 0 V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Body Diode Reverse Recovery Time",+          "symbol": "trr",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 12,+          "max": 20,+          "conditions": "IF = 4 A, dI/dt = 100 A/µs, TJ = 25 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Body Diode Reverse Recovery Charge",+          "symbol": "Qrr",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 5,+          "max": 10,+          "conditions": "IF = 4 A, dI/dt = 100 A/µs, TJ = 25 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain-Source Voltage",+          "symbol": "VDS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "TA = 25 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Gate-Source Voltage",+          "symbol": "VGS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -8,+          "typ": null,+          "max": 8,+          "conditions": "TA = 25 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous Drain Current",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 6,+          "conditions": "TJ = 150 °C, TC = 25 °C (package limited)",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous Drain Current",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 5.1,+          "conditions": "TJ = 150 °C, TC = 70 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous Drain Current",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 5,+          "conditions": "TJ = 150 °C, TA = 25 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous Drain Current",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 4,+          "conditions": "TJ = 150 °C, TA = 70 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Pulsed Drain Current",+          "symbol": "IDM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous Source-Drain Diode Current",+          "symbol": "IS",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 1.75,+          "conditions": "TC = 25 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous Source-Drain Diode Current",+          "symbol": "IS",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 1.04,+          "conditions": "TA = 25 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum Power Dissipation",+          "symbol": "PD",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 2.1,+          "conditions": "TC = 25 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum Power Dissipation",+          "symbol": "PD",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 1.3,+          "conditions": "TC = 70 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum Power Dissipation",+          "symbol": "PD",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 1.25,+          "conditions": "TA = 25 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum Power Dissipation",+          "symbol": "PD",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 0.8,+          "conditions": "TA = 70 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Operating Junction and Storage Temperature Range",+          "symbol": "TJ, Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum Junction-to-Ambient",+          "symbol": "RthJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 80,+          "max": 100,+          "conditions": "t ≤ 5 s",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum Junction-to-Ambient",+          "symbol": "RthJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "Steady state (note d)",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum Junction-to-Foot (Drain)",+          "symbol": "RthJF",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 40,+          "max": 60,+          "conditions": "Steady state",+          "source_page": 1,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -191,4 +630,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}