← Commit history

sed4060g: specified limits as data (metadata.characteristics, 26 rows from the datasheet)

Ray ·e6b0892422 ·23d ago ·parent eb1a9ca
2 files changed +353−1
README.md+33
@@ -27,6 +27,39 @@ SED4060G from SINO IC, in a DFN-8(5x6). Pinout and pin descriptions extracted fr | Category | Transistors/Thyristors | | Pins | 9 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Drain-Source Voltage | VDS |  |  | 40 | V |  | 1 |+| Gate-Source Voltage | VGS | -20 |  | 20 | V |  | 1 |+| Drain Current, Continuous | ID |  |  | 60 | A | Continuous | 1 |+| Drain Current, Pulsed |  |  |  | 200 | A | Pulsed | 1 |+| Total Power Dissipation | PD |  |  | 65 | W | @TA=25℃ | 1 |+| Operating Junction Temperature Range | TJ | -55 |  | 175 | ℃ |  | 1 |+| Thermal Resistance Junction to Case | RθJC |  |  | 5 | ℃/W |  | 1 |+| Drain-Source Breakdown Voltage | BVDSS | 40 |  |  | V | ID=250μA, VGS=0 | 2 |+| Drain to Source Leakage Current | IDSS |  |  | 1 | μA | VDS=40V, VGS=0V | 2 |+| Gate-Body Leakage Current | IGSS |  |  | 300 | nA | VGS=20V | 2 |+| Gate Threshold Voltage | VGS(th) | 1 | 1.6 | 2.2 | V | VDS= VGS, ID=250μA | 2 |+| Static Drain-Source On-Resistance | RDS(ON) |  | 7.5 | 9.5 | mΩ | VGS=10V, ID=20A | 2 |+| Forward Transconductance | gFS |  | 25 |  | S | VDS=5V, ID=20A | 2 |+| Input Capacitance | Ciss |  | 942 |  | pF | VGS=0V, VDS=20V, f=1MHz | 2 |+| Output Capacitance | Coss |  | 309 |  | pF |  | 2 |+| Reverse Transfer Capacitance | Crss |  | 29 |  | pF |  | 2 |+| Total Gate Charge | Qg |  | 14.5 |  | nC | VGS=10V, VDS=20V, ID=10A | 2 |+| Gate Source Charge | Qgs |  | 2 |  | nC |  | 2 |+| Gate Drain Charge | Qgd |  | 2.5 |  | nC |  | 2 |+| Turn-On Delay Time | td(on) |  | 6 |  | ns | VGS=10V, VDS=20V, RGEN=10Ω, ID=10A | 2 |+| Turn-Off Delay Time | td(off) |  | 21 |  | ns |  | 2 |+| Turn-On Rise Time | td(r) |  | 5 |  | ns |  | 2 |+| Turn-Off Fall Time | td(f) |  | 5 |  | ns |  | 2 |+| Diode Forward Voltage | VSD |  |  | 1.2 | V | VGS=0V, IS=20A | 2 |+| Reverse Recovery Time | trr |  | 24 |  | ns | TJ=25℃, IF=10A, Di/dt=100A/μs | 2 |+| Reverse Recovery Charge | Qrr |  | 19 |  | nC |  | 2 |+ ## CAD (KiCad official)  - Symbol: `SED4060G`
page.json+320−1
@@ -184,6 +184,325 @@       "Package": "DFN-8(5x6)",       "Category": "Transistors/Thyristors",       "Pins": "9"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "d399223609a20c19",+      "rows": [+        {+          "name": "Drain-Source Voltage",+          "symbol": "VDS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Gate-Source Voltage",+          "symbol": "VGS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Drain Current, Continuous",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 60,+          "conditions": "Continuous",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Drain Current, Pulsed",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 200,+          "conditions": "Pulsed",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Total Power Dissipation",+          "symbol": "PD",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 65,+          "conditions": "@TA=25℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Operating Junction Temperature Range",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "℃",+          "min": -55,+          "typ": null,+          "max": 175,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Thermal Resistance Junction to Case",+          "symbol": "RθJC",+          "kind": "thermal",+          "unit": "℃/W",+          "min": null,+          "typ": null,+          "max": 5,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Drain-Source Breakdown Voltage",+          "symbol": "BVDSS",+          "kind": "electrical",+          "unit": "V",+          "min": 40,+          "typ": null,+          "max": null,+          "conditions": "ID=250μA, VGS=0",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain to Source Leakage Current",+          "symbol": "IDSS",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "VDS=40V, VGS=0V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate-Body Leakage Current",+          "symbol": "IGSS",+          "kind": "electrical",+          "unit": "nA",+          "min": null,+          "typ": null,+          "max": 300,+          "conditions": "VGS=20V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate Threshold Voltage",+          "symbol": "VGS(th)",+          "kind": "electrical",+          "unit": "V",+          "min": 1,+          "typ": 1.6,+          "max": 2.2,+          "conditions": "VDS= VGS, ID=250μA",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Static Drain-Source On-Resistance",+          "symbol": "RDS(ON)",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": 7.5,+          "max": 9.5,+          "conditions": "VGS=10V, ID=20A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Forward Transconductance",+          "symbol": "gFS",+          "kind": "electrical",+          "unit": "S",+          "min": null,+          "typ": 25,+          "max": null,+          "conditions": "VDS=5V, ID=20A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Input Capacitance",+          "symbol": "Ciss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 942,+          "max": null,+          "conditions": "VGS=0V, VDS=20V, f=1MHz",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Output Capacitance",+          "symbol": "Coss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 309,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Reverse Transfer Capacitance",+          "symbol": "Crss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 29,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Total Gate Charge",+          "symbol": "Qg",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 14.5,+          "max": null,+          "conditions": "VGS=10V, VDS=20V, ID=10A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate Source Charge",+          "symbol": "Qgs",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 2,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate Drain Charge",+          "symbol": "Qgd",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 2.5,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-On Delay Time",+          "symbol": "td(on)",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 6,+          "max": null,+          "conditions": "VGS=10V, VDS=20V, RGEN=10Ω, ID=10A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-Off Delay Time",+          "symbol": "td(off)",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 21,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-On Rise Time",+          "symbol": "td(r)",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 5,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-Off Fall Time",+          "symbol": "td(f)",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 5,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Diode Forward Voltage",+          "symbol": "VSD",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1.2,+          "conditions": "VGS=0V, IS=20A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Reverse Recovery Time",+          "symbol": "trr",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 24,+          "max": null,+          "conditions": "TJ=25℃, IF=10A, Di/dt=100A/μs",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Reverse Recovery Charge",+          "symbol": "Qrr",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 19,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -225,4 +544,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}